{"id":2105,"date":"2025-05-07T06:56:33","date_gmt":"2025-05-07T06:56:33","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2105"},"modified":"2025-05-07T06:56:34","modified_gmt":"2025-05-07T06:56:34","slug":"lla-collar-torque-resistance","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/fr\/lla-collar-torque-resistance\/","title":{"rendered":"R\u00e9sistance au couple du collier LLA"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2105\" class=\"elementor elementor-2105\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3f46df2 e-flex e-con-boxed e-con e-parent\" data-id=\"3f46df2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7b2444a elementor-widget elementor-widget-heading\" data-id=\"7b2444a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">R\u00e9sistance au couple du collier LLA<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8edec19 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"8edec19\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e4ea1f elementor-widget elementor-widget-heading\" data-id=\"0e4ea1f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Annexe G4<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3053d41 e-flex e-con-boxed e-con e-parent\" data-id=\"3053d41\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7d4d20a elementor-widget elementor-widget-text-editor\" data-id=\"7d4d20a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"376\" data-end=\"978\">Dans la fabrication de produits pharmaceutiques, l'int\u00e9grit\u00e9 m\u00e9canique des seringues pr\u00e9remplies est essentielle \u00e0 la s\u00e9curit\u00e9 et \u00e0 la performance des produits. L'un des facteurs cl\u00e9s de cette int\u00e9grit\u00e9 est <strong data-start=\"567\" data-end=\"599\">R\u00e9sistance au couple du collier LLA<\/strong>qui mesure la r\u00e9sistance du collier de l'adaptateur Luer lock (LLA) sous l'effet d'un couple. Cette propri\u00e9t\u00e9 garantit que le collier peut r\u00e9sister \u00e0 la force de rotation lorsque le personnel m\u00e9dical fixe des embouts d'aiguille ou des connecteurs compatibles. La r\u00e9alisation de ce test conform\u00e9ment \u00e0 la norme <em data-start=\"862\" data-end=\"875\">ISO 11040-4<\/em> et <em data-start=\"880\" data-end=\"890\">Annexe G4<\/em> aide les fabricants \u00e0 se conformer \u00e0 la r\u00e9glementation et \u00e0 fournir des produits s\u00fbrs et fonctionnels.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0043965 elementor-widget elementor-widget-heading\" data-id=\"0043965\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">R\u00e9sistance au couple du collier LLA et son importance<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef59016 elementor-widget elementor-widget-text-editor\" data-id=\"ef59016\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"985\" data-end=\"1456\"><strong data-start=\"1047\" data-end=\"1079\">R\u00e9sistance au couple du collier LLA<\/strong> se r\u00e9f\u00e8re \u00e0 la capacit\u00e9 du collier de l'adaptateur Luer lock d'une seringue \u00e0 r\u00e9sister \u00e0 la rotation ou au desserrage lorsqu'un couple est appliqu\u00e9. Dans le monde r\u00e9el, cela simule la contrainte m\u00e9canique exerc\u00e9e lorsqu'un clinicien connecte un dispositif compatible Luer-lock. Un d\u00e9faut de r\u00e9sistance au couple peut entra\u00eener une fuite, une mauvaise administration du m\u00e9dicament ou une contamination, ce qui constitue un risque grave en milieu clinique.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77afa8a elementor-widget elementor-widget-heading\" data-id=\"77afa8a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Norme d'essai des seringues - ISO 11040-4 Annexe G4<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9f4cc74 e-con-full e-flex e-con e-child\" data-id=\"9f4cc74\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0879ad7 elementor-widget elementor-widget-text-editor\" data-id=\"0879ad7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1463\" data-end=\"1902\">Le <strong data-start=\"1525\" data-end=\"1540\">ISO 11040-4<\/strong> intitul\u00e9e <em data-start=\"1558\" data-end=\"1673\">Seringues pr\u00e9remplies - Partie 4 : Barils en verre pour produits injectables et seringues sous-assembl\u00e9es st\u00e9rilis\u00e9es pr\u00eates \u00e0 \u00eatre remplies<\/em>Il d\u00e9crit des m\u00e9thodes d'essai rigoureuses pour garantir la fiabilit\u00e9 des produits. <em data-start=\"1737\" data-end=\"1747\">Annexe G4<\/em> d\u00e9taille sp\u00e9cifiquement la m\u00e9thode d'\u00e9valuation des <strong data-start=\"1794\" data-end=\"1826\">R\u00e9sistance au couple du collier LLA<\/strong>Il s'agit d'un outil indispensable pour les fabricants qui travaillent dans le secteur de l'\u00e9nergie. <strong data-start=\"1882\" data-end=\"1901\">test \u00e0 la seringue<\/strong>.<\/p><p class=\"\" data-start=\"1904\" data-end=\"1941\">Les principaux points de l'annexe G4 sont les suivants<\/p><ul><li data-start=\"1944\" data-end=\"2066\"><strong data-start=\"1944\" data-end=\"1963\">Principe du test :<\/strong> V\u00e9rifie si le collier LLA peut r\u00e9sister \u00e0 un couple lors de la fixation d'un raccord conique Luer standard 6%.<\/li><li data-start=\"2069\" data-end=\"2129\"><strong data-start=\"2069\" data-end=\"2099\">Taux d'\u00e9chantillonnage recommand\u00e9 :<\/strong> 500 Hz pour les mesures de cr\u00eate.<\/li><li data-start=\"2132\" data-end=\"2186\"><strong data-start=\"2132\" data-end=\"2160\">Standard Vitesse de rotation :<\/strong> 20 tr\/min ou comme convenu.<\/li><li data-start=\"2189\" data-end=\"2255\"><strong data-start=\"2189\" data-end=\"2212\">Sortie de mesure :<\/strong> Couple maximal au d\u00e9but du mouvement du collier.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1ed627 elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"d1ed627\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"236\" height=\"361\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing.webp\" class=\"attachment-full size-full wp-image-2107\" alt=\"R\u00e9sistance au couple du collier LLA - Test \u00e0 la seringue ISO 11040-4\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing.webp 236w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing-196x300.webp 196w\" sizes=\"(max-width: 236px) 100vw, 236px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47df98e elementor-widget elementor-widget-heading\" data-id=\"47df98e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00c9quipement de test pour la r\u00e9sistance au couple du collier LLA<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4baaf8e elementor-widget elementor-widget-text-editor\" data-id=\"4baaf8e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2262\" data-end=\"2400\">La r\u00e9alisation du test n\u00e9cessite des instruments de pr\u00e9cision. La configuration standard comprend<\/p><ul><li data-start=\"2403\" data-end=\"2556\"><strong data-start=\"2403\" data-end=\"2441\">Testeur de couple avec dispositif de rotation<\/strong>: Doit \u00eatre capable de d\u00e9tecter le pic de couple avec une r\u00e9solution de <strong data-start=\"2507\" data-end=\"2519\">0,05 Ncm<\/strong>La fourchette id\u00e9ale \u00e9tant <strong data-start=\"2539\" data-end=\"2555\">jusqu'\u00e0 35 Ncm<\/strong>.<\/li><li data-start=\"2559\" data-end=\"2630\"><strong data-start=\"2559\" data-end=\"2581\">Pince \u00e0 collier LLA<\/strong>: Fixe solidement le collier sans l'endommager.<\/li><li data-start=\"2633\" data-end=\"2737\"><strong data-start=\"2633\" data-end=\"2661\">Porte-seringue rotatif<\/strong>: Permet une rotation pr\u00e9cise et constante de la seringue ou du bouchon.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0058def elementor-widget elementor-widget-heading\" data-id=\"0058def\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Guide \u00e9tape par \u00e9tape pour la r\u00e9alisation du test<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e82ef56 elementor-widget elementor-widget-text-editor\" data-id=\"e82ef56\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2938\" data-end=\"3119\">Les professionnels du contr\u00f4le de la qualit\u00e9 peuvent suivre ces \u00e9tapes pour garantir la pr\u00e9cision et la normalisation des essais de <strong data-start=\"3086\" data-end=\"3118\">R\u00e9sistance au couple du collier LLA<\/strong>:<\/p><ol><li data-start=\"3124\" data-end=\"3195\"><strong data-start=\"3124\" data-end=\"3134\">Ins\u00e9rer<\/strong> la seringue st\u00e9rilis\u00e9e sous-assembl\u00e9e dans le porte-seringue.<\/li><li data-start=\"3199\" data-end=\"3231\"><strong data-start=\"3199\" data-end=\"3209\">Retirer<\/strong> l'embout manuellement.<\/li><li data-start=\"3235\" data-end=\"3297\"><strong data-start=\"3235\" data-end=\"3244\">Montage<\/strong> la pince du collier LLA sur le collier LLA.<\/li><li data-start=\"3301\" data-end=\"3355\"><strong data-start=\"3301\" data-end=\"3309\">Z\u00e9ro<\/strong> la cellule dynamom\u00e9trique afin d'\u00e9liminer le couple de pr\u00e9charge.<\/li><li data-start=\"3359\" data-end=\"3416\"><strong data-start=\"3359\" data-end=\"3366\">Set (jeu de mots)<\/strong> la vitesse de rotation \u00e0 20 tr\/min (ou selon le cas).<\/li><li data-start=\"3420\" data-end=\"3509\"><strong data-start=\"3420\" data-end=\"3432\">Initier<\/strong> le test en tournant la seringue ou le bouchon de 90\u00b0 dans le sens indiqu\u00e9.<\/li><li data-start=\"3513\" data-end=\"3568\"><strong data-start=\"3513\" data-end=\"3523\">Enregistrer<\/strong> le couple maximal lorsque le mouvement du collier commence.<\/li><\/ol><p class=\"\" data-start=\"3570\" data-end=\"3675\">Cette valeur de couple refl\u00e8te la <strong data-start=\"3601\" data-end=\"3623\">r\u00e9sistance maximale<\/strong> offert par le collier LLA en cas de stress op\u00e9rationnel.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d445bbc e-con-full e-flex e-con e-child\" data-id=\"d445bbc\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-defbeb6 e-con-full e-flex e-con e-child\" data-id=\"defbeb6\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1c54c92 elementor-widget elementor-widget-heading\" data-id=\"1c54c92\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Rapports d'essais et contr\u00f4le de la qualit\u00e9<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-669ef67 elementor-widget elementor-widget-text-editor\" data-id=\"669ef67\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"3682\" data-end=\"3799\">Selon l'annexe G4 de la norme ISO 11040-4, un rapport d'essai complet doit comprendre les \u00e9l\u00e9ments suivants<\/p><ul><li data-start=\"3802\" data-end=\"3826\">Valeurs du couple de pointe (Ncm)<\/li><li data-start=\"3829\" data-end=\"3849\">Vitesse de rotation (tr\/min)<\/li><li data-start=\"3852\" data-end=\"3876\">Nombre d'\u00e9chantillons test\u00e9s<\/li><li data-start=\"3879\" data-end=\"3896\">R\u00e9sultats de la r\u00e9ussite ou de l'\u00e9chec<\/li><li data-start=\"3899\" data-end=\"3931\">Notes sur les \u00e9carts ou les anomalies<\/li><\/ul><p class=\"\" data-start=\"3933\" data-end=\"4059\">Cette documentation garantit la tra\u00e7abilit\u00e9 et la conformit\u00e9, deux \u00e9l\u00e9ments essentiels pour les audits r\u00e9glementaires et la certification de la mise sur le march\u00e9 des produits.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cb68c8a e-con-full e-flex e-con e-child\" data-id=\"cb68c8a\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c067893 elementor-widget elementor-widget-heading\" data-id=\"c067893\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Avantages du contr\u00f4le automatis\u00e9 du couple<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-36ac35a elementor-widget elementor-widget-text-editor\" data-id=\"36ac35a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4066\" data-end=\"4277\">Chez Cell Instruments, nous sommes sp\u00e9cialis\u00e9s dans les syst\u00e8mes d'essai de pr\u00e9cision, notamment les couplem\u00e8tres con\u00e7us pour <strong data-start=\"4211\" data-end=\"4243\">R\u00e9sistance au couple du collier LLA<\/strong> \u00e9valuations. L'automatisation am\u00e9liore :<\/p><ul><li data-start=\"4280\" data-end=\"4309\"><strong data-start=\"4280\" data-end=\"4309\">R\u00e9p\u00e9tabilit\u00e9 des mesures<\/strong><\/li><li data-start=\"4312\" data-end=\"4329\"><strong data-start=\"4312\" data-end=\"4329\">Pr\u00e9cision des donn\u00e9es<\/strong><\/li><li data-start=\"4332\" data-end=\"4358\"><strong data-start=\"4332\" data-end=\"4358\">Efficacit\u00e9 op\u00e9rationnelle<\/strong><\/li><li data-start=\"4361\" data-end=\"4385\"><strong data-start=\"4361\" data-end=\"4385\">Assurance de la conformit\u00e9<\/strong><\/li><\/ul><p class=\"\" data-start=\"4387\" data-end=\"4527\">Des montages personnalis\u00e9s et l'int\u00e9gration de logiciels permettent aux laboratoires de rationaliser les flux de travail des tests de seringues tout en se conformant strictement aux directives ISO.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-11ccf92 elementor-widget elementor-widget-text-editor\" data-id=\"11ccf92\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4984\" data-end=\"5514\">Comprendre et mettre en \u0153uvre la <strong data-start=\"5036\" data-end=\"5068\">R\u00e9sistance au couple du collier LLA<\/strong> en conformit\u00e9 avec les r\u00e8gles de l'Union europ\u00e9enne. <a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"5092\" data-end=\"5107\">ISO 11040-4<\/strong><\/a> et <strong data-start=\"5112\" data-end=\"5124\">Annexe G4<\/strong> est essentiel pour l'assurance qualit\u00e9 des seringues. Ce test permet de se pr\u00e9munir contre les d\u00e9faillances m\u00e9caniques lors de l'utilisation clinique et aide les fabricants \u00e0 respecter les normes les plus strictes en mati\u00e8re de s\u00e9curit\u00e9 des patients. \u00c0 l'adresse <strong data-start=\"5308\" data-end=\"5328\">Instruments cellulaires<\/strong>Dans le cadre de notre programme d'essais de couple, nous fournissons des solutions d'essais de couple de pointe qui s'alignent sur les normes mondiales et les besoins de l'industrie, permettant aux fabricants de seringues de disposer de donn\u00e9es fiables et d'avoir confiance dans les r\u00e9glementations.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>LLA Collar Torque Resistance ISO 11040-4 Annex G4 In pharmaceutical manufacturing, ensuring the mechanical integrity of prefilled syringes is critical to product safety and performance. One key factor in this integrity is LLA collar torque resistance, which measures the strength of the Luer lock adaptor (LLA) collar under torque. This property ensures that the collar [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2105","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/fr\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"LLA Collar Torque Resistance ISO 11040-4 Annex G4 In pharmaceutical manufacturing, ensuring the mechanical integrity of prefilled syringes is critical to product safety and performance. One key factor in this integrity is LLA collar torque resistance, which measures the strength of the Luer lock adaptor (LLA) collar under torque. This property ensures that the collar\u2026","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts\/2105","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/comments?post=2105"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts\/2105\/revisions"}],"predecessor-version":[{"id":2111,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/posts\/2105\/revisions\/2111"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/media?parent=2105"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/categories?post=2105"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/fr\/wp-json\/wp\/v2\/tags?post=2105"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}