{"id":2105,"date":"2025-05-07T06:56:33","date_gmt":"2025-05-07T06:56:33","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2105"},"modified":"2025-05-07T06:56:34","modified_gmt":"2025-05-07T06:56:34","slug":"lla-collar-torque-resistance","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/es\/lla-collar-torque-resistance\/","title":{"rendered":"Resistencia al par del collar LLA"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2105\" class=\"elementor elementor-2105\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3f46df2 e-flex e-con-boxed e-con e-parent\" data-id=\"3f46df2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7b2444a elementor-widget elementor-widget-heading\" data-id=\"7b2444a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Resistencia al par del collar LLA<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8edec19 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"8edec19\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e4ea1f elementor-widget elementor-widget-heading\" data-id=\"0e4ea1f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Anexo G4<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3053d41 e-flex e-con-boxed e-con e-parent\" data-id=\"3053d41\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7d4d20a elementor-widget elementor-widget-text-editor\" data-id=\"7d4d20a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"376\" data-end=\"978\">En la fabricaci\u00f3n farmac\u00e9utica, garantizar la integridad mec\u00e1nica de las jeringuillas precargadas es fundamental para la seguridad y el rendimiento del producto. Un factor clave de esta integridad es <strong data-start=\"567\" data-end=\"599\">Resistencia a la torsi\u00f3n del collar LLA<\/strong>que mide la resistencia del collar\u00edn del adaptador de cierre Luer (LLA) sometido a torsi\u00f3n. Esta propiedad garantiza que el collar\u00edn puede soportar la fuerza de rotaci\u00f3n cuando el personal m\u00e9dico acopla cubos de agujas o conectores compatibles. La realizaci\u00f3n de esta prueba de acuerdo con <em data-start=\"862\" data-end=\"875\">ISO 11040-4<\/em> y <em data-start=\"880\" data-end=\"890\">Anexo G4<\/em> ayuda a los fabricantes a cumplir la normativa y ofrecer productos seguros y funcionales.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0043965 elementor-widget elementor-widget-heading\" data-id=\"0043965\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">La resistencia al par del collar\u00edn LLA y su importancia<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef59016 elementor-widget elementor-widget-text-editor\" data-id=\"ef59016\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"985\" data-end=\"1456\"><strong data-start=\"1047\" data-end=\"1079\">Resistencia a la torsi\u00f3n del collar LLA<\/strong> se refiere a la capacidad del collar adaptador Luer lock de una jeringa para resistir el giro o el aflojamiento cuando se aplica un par de torsi\u00f3n. En el uso real, esto simula la tensi\u00f3n mec\u00e1nica ejercida cuando un m\u00e9dico conecta un dispositivo compatible con el cierre Luer. Un fallo en la resistencia a la torsi\u00f3n puede provocar fugas, una administraci\u00f3n incorrecta del f\u00e1rmaco o contaminaci\u00f3n, lo que supone un grave riesgo en el \u00e1mbito cl\u00ednico.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77afa8a elementor-widget elementor-widget-heading\" data-id=\"77afa8a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Norma de ensayo de jeringuillas - ISO 11040-4 Anexo G4<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9f4cc74 e-con-full e-flex e-con e-child\" data-id=\"9f4cc74\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0879ad7 elementor-widget elementor-widget-text-editor\" data-id=\"0879ad7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1463\" data-end=\"1902\">En <strong data-start=\"1525\" data-end=\"1540\">ISO 11040-4<\/strong> norma, titulada <em data-start=\"1558\" data-end=\"1673\">Jeringas precargadas - Parte 4: Barriles de vidrio para inyectables y jeringas subensambladas esterilizadas listas para el llenado.<\/em>La Pol\u00edtica Europea de Seguridad y Salud en el Trabajo, describe m\u00e9todos de ensayo rigurosos para garantizar la fiabilidad de los productos. <em data-start=\"1737\" data-end=\"1747\">Anexo G4<\/em> detalla espec\u00edficamente el m\u00e9todo para evaluar <strong data-start=\"1794\" data-end=\"1826\">Resistencia a la torsi\u00f3n del collar LLA<\/strong>por lo que es indispensable para los fabricantes de <strong data-start=\"1882\" data-end=\"1901\">pruebas con jeringa<\/strong>.<\/p><p class=\"\" data-start=\"1904\" data-end=\"1941\">Entre los aspectos m\u00e1s destacados del anexo G4 figuran los siguientes:<\/p><ul><li data-start=\"1944\" data-end=\"2066\"><strong data-start=\"1944\" data-end=\"1963\">Principio de prueba:<\/strong> Verifica si el collar LLA puede soportar la torsi\u00f3n durante la fijaci\u00f3n de un conector c\u00f3nico Luer 6% est\u00e1ndar.<\/li><li data-start=\"2069\" data-end=\"2129\"><strong data-start=\"2069\" data-end=\"2099\">Frecuencia de muestreo recomendada:<\/strong> 500 Hz para mediciones de pico.<\/li><li data-start=\"2132\" data-end=\"2186\"><strong data-start=\"2132\" data-end=\"2160\">Velocidad de rotaci\u00f3n est\u00e1ndar:<\/strong> 20 rpm o seg\u00fan lo acordado.<\/li><li data-start=\"2189\" data-end=\"2255\"><strong data-start=\"2189\" data-end=\"2212\">Salida de medici\u00f3n:<\/strong> Par m\u00e1ximo al inicio del movimiento del collar\u00edn.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1ed627 elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"d1ed627\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"236\" height=\"361\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing.webp\" class=\"attachment-full size-full wp-image-2107\" alt=\"Resistencia a la torsi\u00f3n del collar LLA - Prueba de jeringa ISO 11040-4\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing.webp 236w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing-196x300.webp 196w\" sizes=\"(max-width: 236px) 100vw, 236px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47df98e elementor-widget elementor-widget-heading\" data-id=\"47df98e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Equipo de ensayo de la resistencia al par del collar LLA<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4baaf8e elementor-widget elementor-widget-text-editor\" data-id=\"4baaf8e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2262\" data-end=\"2400\">La realizaci\u00f3n de la prueba requiere instrumentaci\u00f3n de precisi\u00f3n. La configuraci\u00f3n est\u00e1ndar incluye:<\/p><ul><li data-start=\"2403\" data-end=\"2556\"><strong data-start=\"2403\" data-end=\"2441\">Torqu\u00edmetro con dispositivo de rotaci\u00f3n<\/strong>: Debe ser capaz de detectar el par m\u00e1ximo con una resoluci\u00f3n de <strong data-start=\"2507\" data-end=\"2519\">0,05 Ncm<\/strong>siendo el rango ideal <strong data-start=\"2539\" data-end=\"2555\">hasta 35 Ncm<\/strong>.<\/li><li data-start=\"2559\" data-end=\"2630\"><strong data-start=\"2559\" data-end=\"2581\">Sujetacollares LLA<\/strong>: Sujeta firmemente el collar\u00edn sin da\u00f1arlo.<\/li><li data-start=\"2633\" data-end=\"2737\"><strong data-start=\"2633\" data-end=\"2661\">Soporte giratorio para jeringas<\/strong>: Permite una rotaci\u00f3n precisa y constante de la jeringa o del cierre.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0058def elementor-widget elementor-widget-heading\" data-id=\"0058def\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Gu\u00eda paso a paso para realizar la prueba<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e82ef56 elementor-widget elementor-widget-text-editor\" data-id=\"e82ef56\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2938\" data-end=\"3119\">Los profesionales del control de calidad pueden seguir estos pasos para garantizar pruebas precisas y normalizadas de <strong data-start=\"3086\" data-end=\"3118\">Resistencia a la torsi\u00f3n del collar LLA<\/strong>:<\/p><ol><li data-start=\"3124\" data-end=\"3195\"><strong data-start=\"3124\" data-end=\"3134\">Inserte<\/strong> la jeringa subensamblada esterilizada en el soporte de la jeringa.<\/li><li data-start=\"3199\" data-end=\"3231\"><strong data-start=\"3199\" data-end=\"3209\">Eliminar<\/strong> el tap\u00f3n de la punta manualmente.<\/li><li data-start=\"3235\" data-end=\"3297\"><strong data-start=\"3235\" data-end=\"3244\">Monte<\/strong> la pinza del collar\u00edn LLA firmemente en el collar\u00edn LLA.<\/li><li data-start=\"3301\" data-end=\"3355\"><strong data-start=\"3301\" data-end=\"3309\">Cero<\/strong> la c\u00e9lula de par para eliminar el par de precarga.<\/li><li data-start=\"3359\" data-end=\"3416\"><strong data-start=\"3359\" data-end=\"3366\">Establecer<\/strong> la velocidad de rotaci\u00f3n a 20 rpm (o seg\u00fan proceda).<\/li><li data-start=\"3420\" data-end=\"3509\"><strong data-start=\"3420\" data-end=\"3432\">Inicie<\/strong> la prueba girando la jeringa o el cierre 90\u00b0 en la direcci\u00f3n indicada.<\/li><li data-start=\"3513\" data-end=\"3568\"><strong data-start=\"3513\" data-end=\"3523\">Registro<\/strong> el par m\u00e1ximo cuando comienza el movimiento del collar\u00edn.<\/li><\/ol><p class=\"\" data-start=\"3570\" data-end=\"3675\">Este valor de par refleja el <strong data-start=\"3601\" data-end=\"3623\">resistencia m\u00e1xima<\/strong> que ofrece el collar LLA bajo tensi\u00f3n operativa.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d445bbc e-con-full e-flex e-con e-child\" data-id=\"d445bbc\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-defbeb6 e-con-full e-flex e-con e-child\" data-id=\"defbeb6\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1c54c92 elementor-widget elementor-widget-heading\" data-id=\"1c54c92\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Informes de pruebas y control de calidad<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-669ef67 elementor-widget elementor-widget-text-editor\" data-id=\"669ef67\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"3682\" data-end=\"3799\">Seg\u00fan la norma ISO 11040-4, anexo G4, un informe de ensayo completo debe incluir:<\/p><ul><li data-start=\"3802\" data-end=\"3826\">Valores de par m\u00e1ximo (Ncm)<\/li><li data-start=\"3829\" data-end=\"3849\">Velocidad de rotaci\u00f3n (rpm)<\/li><li data-start=\"3852\" data-end=\"3876\">N\u00famero de muestras analizadas<\/li><li data-start=\"3879\" data-end=\"3896\">Resultados de aprobado\/no aprobado<\/li><li data-start=\"3899\" data-end=\"3931\">Notas sobre desviaciones o anomal\u00edas<\/li><\/ul><p class=\"\" data-start=\"3933\" data-end=\"4059\">Esta documentaci\u00f3n garantiza la trazabilidad y el cumplimiento de las normas, dos aspectos fundamentales para las auditor\u00edas reglamentarias y la certificaci\u00f3n de la comercializaci\u00f3n de los productos.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cb68c8a e-con-full e-flex e-con e-child\" data-id=\"cb68c8a\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c067893 elementor-widget elementor-widget-heading\" data-id=\"c067893\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ventajas de las pruebas de par automatizadas<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-36ac35a elementor-widget elementor-widget-text-editor\" data-id=\"36ac35a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4066\" data-end=\"4277\">En Cell Instruments, estamos especializados en sistemas de ensayo de precisi\u00f3n, incluidos los comprobadores de par adaptados para <strong data-start=\"4211\" data-end=\"4243\">Resistencia a la torsi\u00f3n del collar LLA<\/strong> evaluaciones. La automatizaci\u00f3n mejora:<\/p><ul><li data-start=\"4280\" data-end=\"4309\"><strong data-start=\"4280\" data-end=\"4309\">Repetibilidad de la medici\u00f3n<\/strong><\/li><li data-start=\"4312\" data-end=\"4329\"><strong data-start=\"4312\" data-end=\"4329\">Precisi\u00f3n de los datos<\/strong><\/li><li data-start=\"4332\" data-end=\"4358\"><strong data-start=\"4332\" data-end=\"4358\">Eficacia operativa<\/strong><\/li><li data-start=\"4361\" data-end=\"4385\"><strong data-start=\"4361\" data-end=\"4385\">Garant\u00eda de cumplimiento<\/strong><\/li><\/ul><p class=\"\" data-start=\"4387\" data-end=\"4527\">Los dispositivos personalizados y la integraci\u00f3n del software permiten a los laboratorios agilizar los flujos de trabajo de las pruebas con jeringuillas cumpliendo estrictamente las directrices ISO.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-11ccf92 elementor-widget elementor-widget-text-editor\" data-id=\"11ccf92\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4984\" data-end=\"5514\">Comprender y aplicar la <strong data-start=\"5036\" data-end=\"5068\">Resistencia a la torsi\u00f3n del collar LLA<\/strong> prueba en consonancia con <a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"5092\" data-end=\"5107\">ISO 11040-4<\/strong><\/a> y <strong data-start=\"5112\" data-end=\"5124\">Anexo G4<\/strong> es vital para garantizar la calidad de las jeringuillas. Esta prueba protege contra fallos mec\u00e1nicos durante el uso cl\u00ednico y ayuda a los fabricantes a mantener los m\u00e1s altos niveles de seguridad del paciente. En <strong data-start=\"5308\" data-end=\"5328\">Instrumentos celulares<\/strong>Ofrecemos soluciones de ensayo de torsi\u00f3n de \u00faltima generaci\u00f3n que se ajustan a las normas mundiales y a las necesidades del sector, lo que proporciona a los fabricantes de jeringas datos fiables y confianza normativa.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>LLA Collar Torque Resistance ISO 11040-4 Annex G4 In pharmaceutical manufacturing, ensuring the mechanical integrity of prefilled syringes is critical to product safety and performance. One key factor in this integrity is LLA collar torque resistance, which measures the strength of the Luer lock adaptor (LLA) collar under torque. This property ensures that the collar [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2105","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/es\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"LLA Collar Torque Resistance ISO 11040-4 Annex G4 In pharmaceutical manufacturing, ensuring the mechanical integrity of prefilled syringes is critical to product safety and performance. One key factor in this integrity is LLA collar torque resistance, which measures the strength of the Luer lock adaptor (LLA) collar under torque. This property ensures that the collar&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/posts\/2105","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/comments?post=2105"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/posts\/2105\/revisions"}],"predecessor-version":[{"id":2111,"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/posts\/2105\/revisions\/2111"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/media?parent=2105"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/categories?post=2105"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/tags?post=2105"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}