{"id":2073,"date":"2025-04-22T03:59:40","date_gmt":"2025-04-22T03:59:40","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2073"},"modified":"2025-04-22T06:49:25","modified_gmt":"2025-04-22T06:49:25","slug":"luer-cone-breakage-resistance-iso-11040-4","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/es\/luer-cone-breakage-resistance-iso-11040-4\/","title":{"rendered":"Resistencia a la rotura del cono Luer - ISO 11040-4 Anexo C2"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2073\" class=\"elementor elementor-2073\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef785b6 e-flex e-con-boxed e-con e-parent\" data-id=\"ef785b6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6d4a251 elementor-widget elementor-widget-heading\" data-id=\"6d4a251\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Resistencia a la rotura del cono Luer<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b910e1 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"8b910e1\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec4bbc1 elementor-widget elementor-widget-heading\" data-id=\"ec4bbc1\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Anexo C2<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bdc54b0 e-flex e-con-boxed e-con e-parent\" data-id=\"bdc54b0\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a300c79 elementor-widget elementor-widget-text-editor\" data-id=\"a300c79\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"400\" data-end=\"1016\">En la fabricaci\u00f3n de jeringas y el control de calidad, una de las evaluaciones mec\u00e1nicas m\u00e1s cr\u00edticas es la <strong data-start=\"520\" data-end=\"553\">resistencia a la rotura del cono luer<\/strong> ensayo. La integridad estructural del extremo frontal de la jeringa, especialmente el cono luer, afecta directamente tanto a la seguridad del paciente como a la fiabilidad del dispositivo. Para garantizar una evaluaci\u00f3n coherente y normalizada, el <em data-start=\"749\" data-end=\"762\">ISO 11040-4<\/em> Espec\u00edficamente <em data-start=\"785\" data-end=\"795\">Anexo C2<\/em>-describe los procedimientos y requisitos para realizar esta prueba. Este art\u00edculo le guiar\u00e1 a trav\u00e9s del proceso de prueba, el equipo esencial y la interpretaci\u00f3n de los datos necesarios para cumplir con <a href=\"https:\/\/www.pharmacopoeiatest.com\/es\/iso-11040-4\/\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> normas de ensayo.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3c5bd5 elementor-widget elementor-widget-heading\" data-id=\"b3c5bd5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Importancia de la resistencia a la rotura del cono Luer<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60ddf4e elementor-widget elementor-widget-text-editor\" data-id=\"60ddf4e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>El cono luer, situado en el extremo delantero de la jeringa, es un punto d\u00e9bil potencial propenso a sufrir tensiones mec\u00e1nicas durante la manipulaci\u00f3n, el montaje o la inyecci\u00f3n. <strong data-start=\"1248\" data-end=\"1281\">Resistencia a la rotura del cono Luer<\/strong> Las pruebas ayudan a determinar cu\u00e1nta fuerza puede soportar el cono antes de fracturarse. Para los fabricantes de <em data-start=\"1384\" data-end=\"1405\">jeringas precargadas<\/em> y <em data-start=\"1410\" data-end=\"1441\">barriles de vidrio para inyectables<\/em>Esta prueba no es s\u00f3lo un requisito reglamentario, sino una medida de control de calidad fundamental para evitar fallos en las aplicaciones m\u00e9dicas.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d476dd elementor-widget elementor-widget-heading\" data-id=\"3d476dd\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Anexo C2 M\u00e9todo de prueba de resistencia a la rotura del cono Luer<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-642e2e7 elementor-widget elementor-widget-text-editor\" data-id=\"642e2e7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1582\" data-end=\"2040\">En <strong data-start=\"1636\" data-end=\"1651\">ISO 11040-4<\/strong> norma, titulada <em data-start=\"1669\" data-end=\"1784\">Jeringas precargadas - Parte 4: Barriles de vidrio para inyectables y jeringas subensambladas esterilizadas listas para el llenado.<\/em>, incluye <strong data-start=\"1795\" data-end=\"1807\">Anexo C2<\/strong>que detalla la <em data-start=\"1827\" data-end=\"1858\">resistencia a la rotura frontal<\/em> ensayo. Esta secci\u00f3n describe las condiciones en las que debe realizarse el ensayo, incluidos los requisitos de los aparatos, la manipulaci\u00f3n de las muestras, los procedimientos de ensayo y la documentaci\u00f3n de los resultados.<\/p><h3 class=\"\" data-start=\"2042\" data-end=\"2077\">Las condiciones clave de la prueba incluyen:<\/h3><ul><li data-start=\"2080\" data-end=\"2105\">Velocidad de prueba: <strong data-start=\"2092\" data-end=\"2105\">25 mm\/min<\/strong><\/li><li data-start=\"2080\" data-end=\"2105\">Punto de aplicaci\u00f3n: <strong style=\"font-size: 16px;\" data-start=\"2127\" data-end=\"2135\">2 mm<\/strong><span style=\"font-size: 16px;\"> de la punta de la jeringa<\/span><\/li><li data-start=\"2080\" data-end=\"2105\">Frecuencia de muestreo m\u00ednima: <strong style=\"font-size: 16px;\" data-start=\"2182\" data-end=\"2192\">500 Hz<\/strong><span style=\"font-size: 16px;\"> para una precisi\u00f3n de medici\u00f3n m\u00e1xima<\/span><\/li><li data-start=\"2080\" data-end=\"2105\">Fuerza aplicada hasta <strong style=\"font-size: 16px;\" data-start=\"2245\" data-end=\"2263\">rotura de cristales<\/strong><span style=\"font-size: 16px;\"> se produce<\/span><\/li><\/ul><p class=\"\" data-start=\"2272\" data-end=\"2390\">Seguir estas orientaciones garantiza que su <strong data-start=\"2314\" data-end=\"2333\">pruebas con jeringa<\/strong> los procesos siguen siendo trazables, reproducibles y conformes.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4dbc7e2 elementor-widget elementor-widget-heading\" data-id=\"4dbc7e2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Comprobador de jeringuillas para ensayos ISO 11040-4 Anexo C2<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7da5e4d elementor-widget elementor-widget-text-editor\" data-id=\"7da5e4d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2454\" data-end=\"2671\">Para realizar con precisi\u00f3n <strong data-start=\"2476\" data-end=\"2509\">resistencia a la rotura del cono luer<\/strong> pruebas, necesitar\u00e1 un sistema fiable y preciso de <strong data-start=\"2552\" data-end=\"2605\">m\u00e1quina universal de ensayos de tracci\u00f3n y compresi\u00f3n<\/strong>. El aparato debe cumplir estos requisitos ISO 11040-4 Anexo C2:<\/p><ul><li data-start=\"2675\" data-end=\"2729\">A <strong data-start=\"2677\" data-end=\"2690\">c\u00e9lula de carga<\/strong> adecuado para medir las fuerzas de rotura<\/li><li data-start=\"2675\" data-end=\"2729\">Un sistema preciso y programable <strong style=\"font-size: 16px;\" data-start=\"2758\" data-end=\"2780\">control de velocidad de prueba<\/strong><\/li><li data-start=\"2675\" data-end=\"2729\">Una costumbre <strong style=\"font-size: 16px;\" data-start=\"2792\" data-end=\"2834\">soporte y varilla de carga de acero inoxidable<\/strong><\/li><li data-start=\"2675\" data-end=\"2729\">Juegos de adaptadores que se adaptan a la geometr\u00eda del dise\u00f1o de su jeringa<\/li><\/ul><h3 class=\"\" data-start=\"2889\" data-end=\"2967\">Comprobador de jeringas recomendado<\/h3><p class=\"\" data-start=\"2969\" data-end=\"3383\">Instrumentos celulares <em>Comprobador de jeringuillas<\/em>\u00a0est\u00e1 dise\u00f1ado para cumplir los rigurosos requisitos de los ensayos de jeringas ISO. Equipado con control PLC programable, mec\u00e1nica de precisi\u00f3n y accesorios personalizables, el MPT-01 proporciona datos de fuerza y desplazamiento de alta resoluci\u00f3n, por lo que es ideal para... <strong data-start=\"3241\" data-end=\"3274\">resistencia a la rotura del cono luer<\/strong> evaluaciones. La microimpresora integrada y la exportaci\u00f3n de datos RS232 opcional tambi\u00e9n permiten una documentaci\u00f3n detallada.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b4ff2b elementor-widget elementor-widget-heading\" data-id=\"6b4ff2b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Procedimiento de prueba de resistencia a la rotura del cono Luer<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c990a3c e-con-full e-flex e-con e-child\" data-id=\"c990a3c\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-dbcf8eb e-con-full e-flex e-con e-child\" data-id=\"dbcf8eb\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-53324d6 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"53324d6\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"488\" height=\"1024\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp\" class=\"attachment-large size-large wp-image-2048\" alt=\"Prueba de fugas en jeringas ISO 11040-4\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp 488w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-143x300.webp 143w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-768x1613.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-731x1536.webp 731w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-975x2048.webp 975w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-scaled.webp 1219w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9962325 e-con-full e-flex e-con e-child\" data-id=\"9962325\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ea7609b elementor-widget elementor-widget-text-editor\" data-id=\"ea7609b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3460\" data-end=\"3483\"><strong>1. Preparaci\u00f3n de la prueba<\/strong><\/p><ul><li data-start=\"3486\" data-end=\"3553\">Inspeccione todos los adaptadores y materiales para <strong data-start=\"3525\" data-end=\"3552\">da\u00f1os o compatibilidad<\/strong>.<\/li><li data-start=\"3486\" data-end=\"3553\">Monte el adaptador y los accesorios necesarios en el <strong style=\"font-size: 16px;\">Comprobador de jeringuillas<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3486\" data-end=\"3553\">Garantizar una alineaci\u00f3n y <strong style=\"font-size: 16px;\" data-start=\"3652\" data-end=\"3677\">instalar protecciones de seguridad<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><\/ul><p data-start=\"3680\" data-end=\"3704\"><strong>2. Ejecuci\u00f3n de las pruebas<\/strong><\/p><ul><li data-start=\"3707\" data-end=\"3749\">Introduzca la jeringa en el soporte.<\/li><li data-start=\"3707\" data-end=\"3749\">Colocar el pasador de carga <strong style=\"font-size: 16px;\" data-start=\"3777\" data-end=\"3806\">2 mm de la punta de la jeringa<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Ajuste la velocidad a <strong style=\"font-size: 16px;\" data-start=\"3827\" data-end=\"3840\">25 mm\/min<\/strong><span style=\"font-size: 16px;\"> e inicie la prueba.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Aplique compresi\u00f3n hasta que el cono luer <strong style=\"font-size: 16px;\" data-start=\"3901\" data-end=\"3914\">fracturas<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Registre el <strong style=\"font-size: 16px;\" data-start=\"3929\" data-end=\"3958\">fuerza m\u00e1xima de rotura<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4898eec elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"4898eec\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"272\" height=\"270\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing.png\" class=\"attachment-large size-large wp-image-2078\" alt=\"Resistencia a la rotura del cono Luer - ISO 11040-4 Anexo C2 Pruebas de jeringa\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing.png 272w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing-150x150.png 150w\" sizes=\"(max-width: 272px) 100vw, 272px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-322584f elementor-widget elementor-widget-text-editor\" data-id=\"322584f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3961\" data-end=\"3999\"><b>3. Limpieza y an\u00e1lisis posteriores a la prueba<\/b><\/p><ul><li data-start=\"4002\" data-end=\"4038\">Retire con cuidado la jeringa rota.<\/li><li data-start=\"4002\" data-end=\"4038\">Limpie el adaptador para eliminar cualquier resto de vidrio.<\/li><li data-start=\"4002\" data-end=\"4038\">Analizar los resultados y confirmar <strong style=\"font-size: 16px;\" data-start=\"4117\" data-end=\"4138\">localizaci\u00f3n de la fractura<\/strong><span style=\"font-size: 16px;\"> en la parte delantera.<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04ee823 elementor-widget elementor-widget-heading\" data-id=\"04ee823\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Requisitos de notificaci\u00f3n de resultados seg\u00fan ISO 11040-4<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9a8c95c elementor-widget elementor-widget-text-editor\" data-id=\"9a8c95c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4216\" data-end=\"4286\">Cada prueba debe documentarse minuciosamente, incluyendo los siguientes datos:<\/p><ul><li data-start=\"4289\" data-end=\"4313\"><strong data-start=\"4289\" data-end=\"4303\">Velocidad de prueba<\/strong> en mm\/min<\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4316\" data-end=\"4349\">Distancia de la punta de la jeringa<\/strong><span style=\"font-size: 16px;\"> al que se aplic\u00f3 la fuerza<\/span><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4383\" data-end=\"4409\">Fuerza m\u00e1xima de rotura<\/strong><span style=\"font-size: 16px;\"> en newtons (N)<\/span><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4427\" data-end=\"4446\">Cantidad de muestras<\/strong><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4449\" data-end=\"4480\">Cualquier anomal\u00eda o desviaci\u00f3n<\/strong><span style=\"font-size: 16px;\"> del procedimiento<\/span><\/li><\/ul><p class=\"\" data-start=\"4501\" data-end=\"4652\">Este nivel de detalle garantiza la coherencia y permite la trazabilidad, especialmente a la hora de validar nuevos dise\u00f1os de jeringuillas o realizar controles de calidad rutinarios.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c3b5bb elementor-widget elementor-widget-heading\" data-id=\"5c3b5bb\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">\u00bfPor qu\u00e9 elegir Cell Instruments para los ensayos con jeringa?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7471474 elementor-widget elementor-widget-text-editor\" data-id=\"7471474\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4659\" data-end=\"5243\">Con d\u00e9cadas de experiencia en <strong data-start=\"4744\" data-end=\"4779\">ensayos de materiales para productos sanitarios<\/strong>, <strong data-start=\"4781\" data-end=\"4801\">Instrumentos celulares<\/strong> ofrece soluciones de ensayo de \u00faltima generaci\u00f3n adaptadas a las normas ISO y ASTM. Nuestra <strong>Comprobador de jeringuillas<\/strong> est\u00e1 dise\u00f1ado espec\u00edficamente para <strong data-start=\"4971\" data-end=\"4990\">pruebas con jeringa<\/strong> m\u00e9todos, incluidos <strong data-start=\"5010\" data-end=\"5043\">resistencia a la rotura del cono luer<\/strong>. Ya sea en producci\u00f3n, investigaci\u00f3n o verificaci\u00f3n por terceros, Cell Instruments puede proporcionar soluciones personalizadas, integraci\u00f3n de automatizaci\u00f3n y soporte integral para satisfacer sus necesidades de ensayo.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-02c15b6 elementor-widget elementor-widget-text-editor\" data-id=\"02c15b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"5250\" data-end=\"5668\">Performing <strong data-start=\"5278\" data-end=\"5311\">resistencia a la rotura del cono luer<\/strong> pruebas de conformidad con <strong data-start=\"5337\" data-end=\"5361\"><a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> Anexo C2<\/strong> es esencial para garantizar la integridad mec\u00e1nica de los componentes de la jeringa. Mediante el uso de equipos precisos como el <strong>Comprobador de jeringuillas<\/strong>y siguiendo paso a paso el procedimiento exigido por la norma ISO, podr\u00e1 verificar con confianza la calidad del producto, mantener el cumplimiento de la normativa y proteger la seguridad del paciente.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3344b6 elementor-widget elementor-widget-text-editor\" data-id=\"a3344b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"5420\" data-end=\"5503\"><strong data-start=\"5675\" data-end=\"5746\">\u00bfBusca soluciones de ensayo de jeringuillas que cumplan la norma ISO 11040-4?<\/strong><\/p><p class=\"\" data-start=\"5420\" data-end=\"5503\">P\u00f3ngase en contacto con <strong data-start=\"5757\" data-end=\"5787\">Cell Instruments Co.<\/strong> hoy mismo para obtener asesoramiento experto y sistemas de ensayo a medida para sus necesidades de aseguramiento de la calidad de las jeringuillas.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Cone Breakage Resistance ISO 11040-4 Annex C2 In syringe manufacturing and quality control, one of the most critical mechanical assessments is the luer cone breakage resistance test. The structural integrity of the syringe front end, especially the luer cone, directly impacts both patient safety and device reliability. To ensure consistent, standardized evaluation, the ISO [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2073","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/es\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Luer Cone Breakage Resistance ISO 11040-4 Annex C2 In syringe manufacturing and quality control, one of the most critical mechanical assessments is the luer cone breakage resistance test. The structural integrity of the syringe front end, especially the luer cone, directly impacts both patient safety and device reliability. To ensure consistent, standardized evaluation, the ISO&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/posts\/2073","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/comments?post=2073"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/posts\/2073\/revisions"}],"predecessor-version":[{"id":2084,"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/posts\/2073\/revisions\/2084"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/media?parent=2073"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/categories?post=2073"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/es\/wp-json\/wp\/v2\/tags?post=2073"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}