{"id":2429,"date":"2025-11-06T07:49:46","date_gmt":"2025-11-06T07:49:46","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2429"},"modified":"2025-11-06T07:55:39","modified_gmt":"2025-11-06T07:55:39","slug":"iso-9626","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/de\/iso-9626\/","title":{"rendered":"ISO 9626"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2429\" class=\"elementor elementor-2429\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5aa439d7 e-flex e-con-boxed e-con e-parent\" data-id=\"5aa439d7\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-442ef7 elementor-widget elementor-widget-text-editor\" data-id=\"442ef7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><\/h2>\n<!-- \/wp:heading -->\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8d2ddaa e-flex e-con-boxed e-con e-parent\" data-id=\"8d2ddaa\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a1da949 elementor-widget elementor-widget-heading\" data-id=\"a1da949\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 9626 <br><small><small>Edelstahl-Nadel\u00f6hrchentest<\/small><\/small><\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-28c31c0 e-con-full e-flex e-con e-child\" data-id=\"28c31c0\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b07c887 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"b07c887\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"463\" data-end=\"992\"><strong data-start=\"463\" data-end=\"475\">ISO 9626<\/strong> spezifiziert die Anforderungen und <strong data-start=\"507\" data-end=\"557\">Pr\u00fcfverfahren f\u00fcr Nadelschl\u00e4uche aus nichtrostendem Stahl<\/strong> die bei der Herstellung von Medizinprodukten wie Injektionsnadeln und Kan\u00fclen verwendet werden. Diese internationale Norm gew\u00e4hrleistet, dass die in medizinischen Anwendungen verwendeten Schl\u00e4uche einheitliche Leistungs- und Sicherheitsanforderungen erf\u00fcllen. Zwei wichtige Pr\u00fcfungen nach ISO 9626 sind die <strong data-start=\"814\" data-end=\"842\">Pr\u00fcfung der Steifigkeit der Schl\u00e4uche<\/strong> und die <strong data-start=\"851\" data-end=\"892\">Bruchsicherheit der Schl\u00e4uche<\/strong>die f\u00fcr die Beurteilung der mechanischen Unversehrtheit und Haltbarkeit von Rohren aus nichtrostendem Stahl unerl\u00e4sslich sind.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34234b5 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"34234b5\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/11\/ISO-9626---Stainless-Steel-Needle-Tubing-Stiffness-and-Break-Strength-Testing.webp\" class=\"attachment-full size-full wp-image-2435\" alt=\"ISO 9626 - Pr\u00fcfung der Steifigkeit und Bruchfestigkeit von Nadelrohren aus Edelstahl\" srcset=\"\" sizes=\"(max-width: 600px) 100vw, 600px\" data-srcset=\"\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0df13d1 elementor-widget elementor-widget-heading\" data-id=\"0df13d1\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Was ist ISO 9626?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-185e4a4 elementor-widget elementor-widget-text-editor\" data-id=\"185e4a4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1106\" data-end=\"1422\">Die Norm ISO 9626, vollst\u00e4ndiger Titel <em data-start=\"1346\" data-end=\"1450\">\"Nadelrohre aus nichtrostendem Stahl f\u00fcr die Herstellung von Medizinprodukten - Anforderungen und Pr\u00fcfverfahren\".<\/em>gilt f\u00fcr <strong data-start=\"1463\" data-end=\"1502\">starrer Nadelschlauch aus rostfreiem Stahl<\/strong> geeignet f\u00fcr die Herstellung von Injektionsnadeln und anderen Komponenten f\u00fcr medizinische Ger\u00e4te.<\/p>\n<p data-start=\"1283\" data-end=\"1620\">Die ISO 9626 tr\u00e4gt entscheidend dazu bei, dass die f\u00fcr medizinische Nadeln verwendeten Edelstahlrohre eine ausreichende <strong data-start=\"1393\" data-end=\"1416\">mechanische Festigkeit<\/strong>, <strong data-start=\"1418\" data-end=\"1433\">Flexibilit\u00e4t<\/strong>und <strong data-start=\"1439\" data-end=\"1464\">Widerstandsf\u00e4higkeit gegen Erm\u00fcdung<\/strong>. Schl\u00e4uche, die diese Anforderungen nicht erf\u00fcllen, k\u00f6nnen dazu f\u00fchren, dass sich die Nadel w\u00e4hrend der Verwendung verbiegt oder bricht, was eine Gefahr f\u00fcr Patienten und medizinisches Personal darstellt.<\/p>\n<p data-start=\"1622\" data-end=\"1645\">Die Norm definiert:<\/p>\n<ul>\n<li data-start=\"1648\" data-end=\"1705\"><strong data-start=\"1648\" data-end=\"1675\">Angaben zum Material<\/strong> f\u00fcr Rohre aus rostfreiem Stahl.<\/li>\n<li data-start=\"1708\" data-end=\"1775\"><strong data-start=\"1708\" data-end=\"1734\">Toleranzen bei den Abmessungen<\/strong> einschlie\u00dflich Wandst\u00e4rke und Durchmesser.<\/li>\n<li data-start=\"1778\" data-end=\"1853\"><strong data-start=\"1778\" data-end=\"1807\">Pr\u00fcfungen der mechanischen Eigenschaften<\/strong>wie Steifigkeit und Bruchsicherheit.<\/li>\n<\/ul>\n<p data-start=\"1855\" data-end=\"1991\">Die Einhaltung der ISO 9626 hilft den Herstellern, eine gleichbleibende Produktqualit\u00e4t zu gew\u00e4hrleisten und die internationalen Vorschriften f\u00fcr Medizinprodukte einzuhalten.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-304c484 elementor-widget elementor-widget-heading\" data-id=\"304c484\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Bei der Beurteilung von Schl\u00e4uchen f\u00fcr medizinische Ger\u00e4te sind zwei mechanische Leistungsaspekte besonders wichtig:<\/p>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a08344a elementor-widget elementor-widget-heading\" data-id=\"a08344a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Pr\u00fcfung der Steifigkeit von Schl\u00e4uchen<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8605095 elementor-widget elementor-widget-text-editor\" data-id=\"8605095\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2030\" data-end=\"2392\">Die <strong data-start=\"2034\" data-end=\"2062\">Pr\u00fcfung der Steifigkeit der Schl\u00e4uche<\/strong> bewertet, wie widerstandsf\u00e4hig der Nadelschlauch aus rostfreiem Stahl gegen Verformung ist, wenn eine Kraft aufgebracht wird. Gem\u00e4\u00df ISO 9626 Anhang B wird bei der Pr\u00fcfung eine bestimmte L\u00e4nge des Schlauches an beiden Enden gehalten und eine bekannte Kraft aufgebracht. <strong data-start=\"2287\" data-end=\"2319\">nach unten gerichtete Kraft in seinem Zentrum<\/strong>. Der Betrag von <strong data-start=\"2335\" data-end=\"2349\">Ablenkung<\/strong> wird dann gemessen, um die Steifigkeit zu bestimmen.<\/p>\n<p data-start=\"2394\" data-end=\"2540\">Dieser Test gibt Aufschluss dar\u00fcber, wie stark sich die Schl\u00e4uche unter Belastung biegen - ein Schl\u00fcsselfaktor f\u00fcr die Gew\u00e4hrleistung der <strong data-start=\"2498\" data-end=\"2537\">die Stabilit\u00e4t der Nadel w\u00e4hrend des Einstichs<\/strong>.<\/p>\n<h4 data-start=\"2542\" data-end=\"2567\">\u00dcberblick \u00fcber das Verfahren<\/h4>\n<ol data-start=\"2568\" data-end=\"2856\">\n<li data-start=\"2568\" data-end=\"2669\">\n<p data-start=\"2571\" data-end=\"2669\">Die Schl\u00e4uche werden auf einen <strong data-start=\"2597\" data-end=\"2628\">Steifigkeitspr\u00fcfger\u00e4t<\/strong> mit einer bestimmten Spanne, die sich nach ihrer Gr\u00f6\u00dfe richtet.<\/p>\n<\/li>\n<li data-start=\"2670\" data-end=\"2768\">\n<p data-start=\"2673\" data-end=\"2768\">A <strong data-start=\"2675\" data-end=\"2694\">Ladekolben<\/strong> eine nach unten gerichtete Kraft mit einer Geschwindigkeit zwischen <strong data-start=\"2739\" data-end=\"2765\">1 mm\/min und 10 mm\/min<\/strong>.<\/p>\n<\/li>\n<li data-start=\"2769\" data-end=\"2856\">\n<p data-start=\"2772\" data-end=\"2856\">Die <strong data-start=\"2776\" data-end=\"2790\">Ablenkung<\/strong> an der Verladestelle wird auf die n\u00e4chste Stelle genau aufgezeichnet <strong data-start=\"2842\" data-end=\"2853\">0,01 mm<\/strong>.<\/p>\n<\/li>\n<\/ol>\n<p data-start=\"2858\" data-end=\"3058\">Eine h\u00f6here Steifigkeit deutet auf st\u00e4rkere Schl\u00e4uche hin, die sich nicht biegen lassen, w\u00e4hrend eine geringere Steifigkeit auf eine h\u00f6here Flexibilit\u00e4t schlie\u00dfen l\u00e4sst. Beide Eigenschaften sind je nach der geplanten medizinischen Anwendung wichtig.<\/p>\n<p data-start=\"3060\" data-end=\"3349\"><strong data-start=\"3060\" data-end=\"3098\">Cell Instruments' Steifigkeitspr\u00fcfer<\/strong> bietet ein pr\u00e4zisionsgesteuertes Belastungssystem und eine digitale Wegmessung, die vollst\u00e4ndig den Anforderungen der ISO 9626 entspricht. Es erm\u00f6glicht Labors die Durchf\u00fchrung von <strong data-start=\"3260\" data-end=\"3309\">Steifigkeitspr\u00fcfungen von Nadelrohren aus Edelstahl<\/strong> mit hoher Genauigkeit und Wiederholbarkeit.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80ffe02 elementor-widget elementor-widget-heading\" data-id=\"80ffe02\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Bruchsicherheit von Schl\u00e4uchen<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24288c0 elementor-widget elementor-widget-text-editor\" data-id=\"24288c0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3396\" data-end=\"3665\">Die <strong data-start=\"3400\" data-end=\"3441\">Bruchsicherheit der Schl\u00e4uche<\/strong> (ISO 9626 Anhang C) wird die F\u00e4higkeit des Schlauches bewertet, wiederholten Biegungen standzuhalten, ohne zu rei\u00dfen oder zu brechen. Dies simuliert reale Bedingungen, unter denen eine Nadel w\u00e4hrend der Handhabung oder Verwendung zyklischen Belastungen ausgesetzt sein kann.<\/p>\n<h4 data-start=\"3667\" data-end=\"3688\">Test-Prinzip<\/h4>\n<p data-start=\"3689\" data-end=\"4019\">Ein Ende des Schlauches ist starr befestigt, und ein <strong data-start=\"3735\" data-end=\"3761\">Wiederholte Biegekraft<\/strong> wird in einem bestimmten Abstand angebracht. Die Schl\u00e4uche werden abwechselnd in entgegengesetzte Richtungen um einen bestimmten Winkel gebogen - typischerweise <strong data-start=\"3887\" data-end=\"3920\">25\u00b0 f\u00fcr normalwandige Rohre<\/strong>, <strong data-start=\"3922\" data-end=\"3945\">20\u00b0 f\u00fcr d\u00fcnnwandige<\/strong>und <strong data-start=\"3951\" data-end=\"3987\">15\u00b0 f\u00fcr ultrad\u00fcnnwandige Rohre<\/strong> - f\u00fcr <strong data-start=\"3994\" data-end=\"4016\">20 vollst\u00e4ndige Zyklen<\/strong>.<\/p>\n<p data-start=\"4021\" data-end=\"4096\">Nach der Pr\u00fcfung werden die Schl\u00e4uche visuell auf Anzeichen von Br\u00fcchen untersucht.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-54ef89d e-flex e-con-boxed e-con e-child\" data-id=\"54ef89d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d72668b elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"d72668b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><strong data-start=\"4098\" data-end=\"4143\">Cell-Instrumente <a href=\"https:\/\/www.pharmacopoeiatest.com\/de\/medical-needle-break-resistance-tester\/\" target=\"_blank\" rel=\"noopener\" data-wplink-edit=\"true\">Bruchwiderstandspr\u00fcfer<\/a><\/strong> verf\u00fcgt \u00fcber eine programmierbare zyklische Bewegungssteuerung und ein pr\u00e4zises Winkelverschiebungssystem, das eine genaue Bewertung der Rohrleitung erm\u00f6glicht. <strong data-start=\"4276\" data-end=\"4298\">Erm\u00fcdungsfestigkeit<\/strong> und <strong data-start=\"4303\" data-end=\"4317\">Haltbarkeit<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d56cba elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"5d56cba\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.pharmacopoeiatest.com\/de\/medical-needle-break-resistance-tester\/\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester.webp\" class=\"attachment-large size-large wp-image-1924\" alt=\"Tester f\u00fcr den Bruchwiderstand von medizinischen Nadeln\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester.webp 1000w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester-300x300.webp 300w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester-150x150.webp 150w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester-768x768.webp 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7bc2f44 elementor-widget elementor-widget-heading\" data-id=\"7bc2f44\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">FAQs<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d7e535a elementor-widget elementor-widget-toggle\" data-id=\"d7e535a\" data-element_type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2261\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-2261\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">F1: Was ist ISO 9626?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2261\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-2261\"><p data-start=\"5213\" data-end=\"5511\"><strong data-start=\"5241\" data-end=\"5247\">A:<\/strong> <a href=\"https:\/\/www.iso.org\/standard\/60480.html\" target=\"_blank\" rel=\"noopener\">ISO 9626<\/a> ist eine internationale Norm, die die Anforderungen und Pr\u00fcfverfahren f\u00fcr <strong data-start=\"5335\" data-end=\"5368\">Edelstahl-Nadelschl\u00e4uche<\/strong> die bei der Herstellung medizinischer Ger\u00e4te verwendet werden. Sie definiert Parameter f\u00fcr Abmessungen, Steifigkeit, Bruchfestigkeit und die allgemeine mechanische Leistung.<\/p>\n<p data-start=\"5513\" data-end=\"5787\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2262\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-2262\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">F2: Warum ist die Steifigkeit der Schlauchpr\u00fcfung wichtig?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2262\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-2262\"><p data-start=\"5513\" data-end=\"5787\"><strong data-start=\"5570\" data-end=\"5576\">A:<\/strong> Die <strong data-start=\"5581\" data-end=\"5609\">Pr\u00fcfung der Steifigkeit der Schl\u00e4uche<\/strong> sorgt daf\u00fcr, dass der Schlauch eine ausreichende Steifigkeit beh\u00e4lt und sich unter Belastung nicht \u00fcberm\u00e4\u00dfig biegt. Er ist entscheidend f\u00fcr die Stabilit\u00e4t und Pr\u00e4zision medizinischer Nadeln beim Einf\u00fchren.<\/p>\n<p data-start=\"5789\" data-end=\"6071\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2263\" class=\"elementor-tab-title\" data-tab=\"3\" role=\"button\" aria-controls=\"elementor-tab-content-2263\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">F3: Was wird bei der Pr\u00fcfung der Bruchfestigkeit von Schl\u00e4uchen bewertet?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2263\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"region\" aria-labelledby=\"elementor-tab-title-2263\"><p data-start=\"5789\" data-end=\"6071\"><strong data-start=\"5861\" data-end=\"5867\">A:<\/strong> Dieser Test misst die F\u00e4higkeit der Schl\u00e4uche, folgenden Anforderungen standzuhalten <strong data-start=\"5921\" data-end=\"5948\">wiederholte Biegezyklen<\/strong> ohne Rissbildung. Sie tr\u00e4gt dazu bei, die Haltbarkeit und Sicherheit von medizinischen Schl\u00e4uchen aus Edelstahl in klinischen Anwendungen zu best\u00e4tigen.<\/p>\n<p data-start=\"6073\" data-end=\"6350\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2264\" class=\"elementor-tab-title\" data-tab=\"4\" role=\"button\" aria-controls=\"elementor-tab-content-2264\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">F4: Welche Ger\u00e4te k\u00f6nnen ISO 9626-Pr\u00fcfungen durchf\u00fchren?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2264\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"region\" aria-labelledby=\"elementor-tab-title-2264\"><p data-start=\"6073\" data-end=\"6350\"><strong data-start=\"6129\" data-end=\"6135\">A:<\/strong> <strong data-start=\"6136\" data-end=\"6202\">Cell Instruments' Steifigkeits- und Bruchfestigkeitspr\u00fcfger\u00e4t<\/strong> wurden speziell f\u00fcr die Durchf\u00fchrung von ISO 9626-konformen Pr\u00fcfungen entwickelt und bieten eine pr\u00e4zise Kraftkontrolle, automatische Messungen und eine zuverl\u00e4ssige Wiederholbarkeit.<\/p>\n<p data-start=\"6352\" data-end=\"6632\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2265\" class=\"elementor-tab-title\" data-tab=\"5\" role=\"button\" aria-controls=\"elementor-tab-content-2265\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">F5: Wer sollte Pr\u00fcfungen nach ISO 9626 durchf\u00fchren?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2265\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"5\" role=\"region\" aria-labelledby=\"elementor-tab-title-2265\"><p data-start=\"6352\" data-end=\"6632\"><strong data-start=\"6397\" data-end=\"6403\">A:<\/strong> Qualit\u00e4tskontrollingenieure, Labortechniker und Hersteller medizinischer Ger\u00e4te, die produzieren oder validieren <strong data-start=\"6512\" data-end=\"6545\">Edelstahl-Nadelschl\u00e4uche<\/strong> sollten diese Tests durchf\u00fchren, um die Einhaltung der internationalen Sicherheitsstandards zu gew\u00e4hrleisten.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 9626 Stainless Steel Needle Tubing Test ISO 9626 specifies the requirements and test methods for stainless steel needle tubing used in the manufacture of medical devices such as hypodermic needles and cannulas. This international standard ensures that the tubing used in medical applications meets consistent performance and safety requirements. Two key tests under ISO [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2429","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/de\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 9626 Stainless Steel Needle Tubing Test ISO 9626 specifies the requirements and test methods for stainless steel needle tubing used in the manufacture of medical devices such as hypodermic needles and cannulas. This international standard ensures that the tubing used in medical applications meets consistent performance and safety requirements. Two key tests under ISO&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/posts\/2429","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/comments?post=2429"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/posts\/2429\/revisions"}],"predecessor-version":[{"id":2445,"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/posts\/2429\/revisions\/2445"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/media?parent=2429"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/categories?post=2429"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/tags?post=2429"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}