{"id":2073,"date":"2025-04-22T03:59:40","date_gmt":"2025-04-22T03:59:40","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2073"},"modified":"2025-04-22T06:49:25","modified_gmt":"2025-04-22T06:49:25","slug":"luer-cone-breakage-resistance-iso-11040-4","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/de\/luer-cone-breakage-resistance-iso-11040-4\/","title":{"rendered":"Bruchfestigkeit des Luer-Kegels - ISO 11040-4 Anhang C2"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2073\" class=\"elementor elementor-2073\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef785b6 e-flex e-con-boxed e-con e-parent\" data-id=\"ef785b6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6d4a251 elementor-widget elementor-widget-heading\" data-id=\"6d4a251\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Luer-Kegel-Bruchwiderstand<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b910e1 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"8b910e1\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec4bbc1 elementor-widget elementor-widget-heading\" data-id=\"ec4bbc1\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Anhang C2<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bdc54b0 e-flex e-con-boxed e-con e-parent\" data-id=\"bdc54b0\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a300c79 elementor-widget elementor-widget-text-editor\" data-id=\"a300c79\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"400\" data-end=\"1016\">Bei der Herstellung und Qualit\u00e4tskontrolle von Spritzen ist eine der wichtigsten mechanischen Bewertungen die <strong data-start=\"520\" data-end=\"553\">Luer-Kegel-Bruchfestigkeit<\/strong> Pr\u00fcfung. Die strukturelle Integrit\u00e4t des Spritzenvorderteils, insbesondere des Luer-Kegels, hat direkte Auswirkungen auf die Patientensicherheit und die Zuverl\u00e4ssigkeit des Ger\u00e4ts. Um eine konsistente, standardisierte Bewertung zu gew\u00e4hrleisten, ist die <em data-start=\"749\" data-end=\"762\">ISO 11040-4<\/em> Standard - speziell <em data-start=\"785\" data-end=\"795\">Anhang C2<\/em>-werden die Verfahren und Anforderungen f\u00fcr die Durchf\u00fchrung dieser Pr\u00fcfung beschrieben. Dieser Artikel f\u00fchrt Sie durch den Pr\u00fcfprozess, die notwendige Ausr\u00fcstung und die Interpretation der Daten, die f\u00fcr die Einhaltung der <a href=\"https:\/\/www.pharmacopoeiatest.com\/de\/iso-11040-4\/\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> Pr\u00fcfnormen.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3c5bd5 elementor-widget elementor-widget-heading\" data-id=\"b3c5bd5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Bedeutung der Bruchfestigkeit des Luer-Konus<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60ddf4e elementor-widget elementor-widget-text-editor\" data-id=\"60ddf4e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Der Luer-Konus, der sich am vorderen Ende des Spritzenk\u00f6rpers befindet, ist eine potenzielle Schwachstelle, die bei der Handhabung, Montage oder Injektion mechanisch belastet werden kann. <strong data-start=\"1248\" data-end=\"1281\">Bruchsicherheit des Luer-Kegels<\/strong> Mit Hilfe von Tests l\u00e4sst sich feststellen, wie viel Kraft der Kegel aushalten kann, bevor er bricht. F\u00fcr Hersteller von <em data-start=\"1384\" data-end=\"1405\">vorgef\u00fcllte Spritzen<\/em> und <em data-start=\"1410\" data-end=\"1441\">Glasf\u00e4sser f\u00fcr Injektionsmittel<\/em>Dieser Test ist nicht nur eine gesetzliche Vorschrift, sondern auch eine grundlegende Qualit\u00e4tskontrollma\u00dfnahme zur Vermeidung von Fehlern bei medizinischen Anwendungen.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d476dd elementor-widget elementor-widget-heading\" data-id=\"3d476dd\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Anhang C2 Pr\u00fcfverfahren f\u00fcr die Bruchfestigkeit des Luer-Kegels<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-642e2e7 elementor-widget elementor-widget-text-editor\" data-id=\"642e2e7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1582\" data-end=\"2040\">Die <strong data-start=\"1636\" data-end=\"1651\">ISO 11040-4<\/strong> Standard, mit dem Titel <em data-start=\"1669\" data-end=\"1784\">Vorgef\u00fcllte Spritzen - Teil 4: Glaszylinder f\u00fcr Injektionsmittel und sterilisierte, f\u00fcllfertige Fertigspritzen<\/em>umfasst <strong data-start=\"1795\" data-end=\"1807\">Anhang C2<\/strong>in dem die Einzelheiten der <em data-start=\"1827\" data-end=\"1858\">Bruchsicherheit des vorderen Endes<\/em> Pr\u00fcfung. In diesem Abschnitt werden die Bedingungen beschrieben, unter denen die Pr\u00fcfung durchgef\u00fchrt werden muss, einschlie\u00dflich der Anforderungen an die Ger\u00e4te, die Handhabung der Proben, die Pr\u00fcfverfahren und die Dokumentation der Ergebnisse.<\/p><h3 class=\"\" data-start=\"2042\" data-end=\"2077\">Zu den wichtigsten Testbedingungen geh\u00f6ren:<\/h3><ul><li data-start=\"2080\" data-end=\"2105\">Testgeschwindigkeit: <strong data-start=\"2092\" data-end=\"2105\">25 mm\/min<\/strong><\/li><li data-start=\"2080\" data-end=\"2105\">Anwendungspunkt: <strong style=\"font-size: 16px;\" data-start=\"2127\" data-end=\"2135\">2 mm<\/strong><span style=\"font-size: 16px;\"> von der Spritzenspitze<\/span><\/li><li data-start=\"2080\" data-end=\"2105\">Minimale Abtastrate: <strong style=\"font-size: 16px;\" data-start=\"2182\" data-end=\"2192\">500 Hz<\/strong><span style=\"font-size: 16px;\"> f\u00fcr h\u00f6chste Messgenauigkeit<\/span><\/li><li data-start=\"2080\" data-end=\"2105\">Kraft aufgewendet bis <strong style=\"font-size: 16px;\" data-start=\"2245\" data-end=\"2263\">Glasbruch<\/strong><span style=\"font-size: 16px;\"> erfolgt<\/span><\/li><\/ul><p class=\"\" data-start=\"2272\" data-end=\"2390\">Die Befolgung dieser Anleitung stellt sicher, dass Ihre <strong data-start=\"2314\" data-end=\"2333\">Spritzenversuch<\/strong> Prozesse bleiben nachvollziehbar, reproduzierbar und konform.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4dbc7e2 elementor-widget elementor-widget-heading\" data-id=\"4dbc7e2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Spritzenpr\u00fcfger\u00e4t f\u00fcr die Pr\u00fcfung nach ISO 11040-4 Anhang C2<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7da5e4d elementor-widget elementor-widget-text-editor\" data-id=\"7da5e4d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2454\" data-end=\"2671\">Zur genauen Durchf\u00fchrung <strong data-start=\"2476\" data-end=\"2509\">Luer-Kegel-Bruchfestigkeit<\/strong> Tests ben\u00f6tigen Sie ein zuverl\u00e4ssiges und pr\u00e4zises <strong data-start=\"2552\" data-end=\"2605\">Universal-Zug- und Druckpr\u00fcfmaschine<\/strong>. Das Ger\u00e4t muss diese Anforderungen nach ISO 11040-4 Anhang C2 erf\u00fcllen:<\/p><ul><li data-start=\"2675\" data-end=\"2729\">A <strong data-start=\"2677\" data-end=\"2690\">W\u00e4gezelle<\/strong> geeignet f\u00fcr die Messung von Bruchkr\u00e4ften<\/li><li data-start=\"2675\" data-end=\"2729\">Eine genaue, programmierbare <strong style=\"font-size: 16px;\" data-start=\"2758\" data-end=\"2780\">Testgeschwindigkeitskontrolle<\/strong><\/li><li data-start=\"2675\" data-end=\"2729\">Ein Brauch <strong style=\"font-size: 16px;\" data-start=\"2792\" data-end=\"2834\">Halterung und Ladestange aus rostfreiem Stahl<\/strong><\/li><li data-start=\"2675\" data-end=\"2729\">Adapter-Sets passend zu Ihrer Spritzengeometrie<\/li><\/ul><h3 class=\"\" data-start=\"2889\" data-end=\"2967\">Empfohlenes Spritzenpr\u00fcfger\u00e4t<\/h3><p class=\"\" data-start=\"2969\" data-end=\"3383\">Cell-Instrumente <em>Spritzenpr\u00fcfger\u00e4t<\/em>\u00a0wurde entwickelt, um die strengen Anforderungen der ISO-Spritzenpr\u00fcfung zu erf\u00fcllen. Ausgestattet mit programmierbarer SPS-Steuerung, Pr\u00e4zisionsmechanik und anpassbaren Spannvorrichtungen, liefert der MPT-01 hochaufl\u00f6sende Kraft- und Wegdaten und ist damit ideal f\u00fcr <strong data-start=\"3241\" data-end=\"3274\">Luer-Kegel-Bruchfestigkeit<\/strong> Auswertungen. Der integrierte Mikrodrucker und der optionale RS232-Datenexport unterst\u00fctzen zudem eine detaillierte Dokumentation.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b4ff2b elementor-widget elementor-widget-heading\" data-id=\"6b4ff2b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testverfahren f\u00fcr die Bruchfestigkeit des Luer-Kegels<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c990a3c e-con-full e-flex e-con e-child\" data-id=\"c990a3c\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-dbcf8eb e-con-full e-flex e-con e-child\" data-id=\"dbcf8eb\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-53324d6 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"53324d6\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"488\" height=\"1024\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp\" class=\"attachment-large size-large wp-image-2048\" alt=\"ISO 11040-4 Dichtheitspr\u00fcfung von Spritzen\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp 488w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-143x300.webp 143w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-768x1613.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-731x1536.webp 731w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-975x2048.webp 975w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-scaled.webp 1219w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9962325 e-con-full e-flex e-con e-child\" data-id=\"9962325\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ea7609b elementor-widget elementor-widget-text-editor\" data-id=\"ea7609b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3460\" data-end=\"3483\"><strong>1. Testvorbereitung<\/strong><\/p><ul><li data-start=\"3486\" data-end=\"3553\">Pr\u00fcfen Sie alle Adapter und Materialien auf <strong data-start=\"3525\" data-end=\"3552\">Besch\u00e4digung oder Kompatibilit\u00e4t<\/strong>.<\/li><li data-start=\"3486\" data-end=\"3553\">Montieren Sie den erforderlichen Adapter und die Halterungen an der <strong style=\"font-size: 16px;\">Spritzenpr\u00fcfger\u00e4t<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3486\" data-end=\"3553\">Sicherstellung der korrekten Ausrichtung und <strong style=\"font-size: 16px;\" data-start=\"3652\" data-end=\"3677\">Schutzvorrichtungen anbringen<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><\/ul><p data-start=\"3680\" data-end=\"3704\"><strong>2. Testdurchf\u00fchrung<\/strong><\/p><ul><li data-start=\"3707\" data-end=\"3749\">Setzen Sie den Spritzenzylinder in die Halterung ein.<\/li><li data-start=\"3707\" data-end=\"3749\">Positionieren Sie den Ladestift <strong style=\"font-size: 16px;\" data-start=\"3777\" data-end=\"3806\">2 mm von der Spritzenspitze entfernt<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Stellen Sie die Geschwindigkeit auf <strong style=\"font-size: 16px;\" data-start=\"3827\" data-end=\"3840\">25 mm\/min<\/strong><span style=\"font-size: 16px;\"> und starten Sie den Test.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Kompression anwenden, bis der Luer-Konus <strong style=\"font-size: 16px;\" data-start=\"3901\" data-end=\"3914\">Frakturen<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Aufzeichnung der <strong style=\"font-size: 16px;\" data-start=\"3929\" data-end=\"3958\">maximale Kraft bei Bruch<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4898eec elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"4898eec\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"272\" height=\"270\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing.png\" class=\"attachment-large size-large wp-image-2078\" alt=\"Luer-Konus-Bruchfestigkeit - ISO 11040-4 Anhang C2 Spritzenpr\u00fcfung\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing.png 272w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing-150x150.png 150w\" sizes=\"(max-width: 272px) 100vw, 272px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-322584f elementor-widget elementor-widget-text-editor\" data-id=\"322584f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3961\" data-end=\"3999\"><b>3. Bereinigung und Analyse nach dem Test<\/b><\/p><ul><li data-start=\"4002\" data-end=\"4038\">Entfernen Sie die zerbrochene Spritze vorsichtig.<\/li><li data-start=\"4002\" data-end=\"4038\">Reinigen Sie den Adapter, um Glasreste zu entfernen.<\/li><li data-start=\"4002\" data-end=\"4038\">Analysieren Sie die Ergebnisse und best\u00e4tigen Sie <strong style=\"font-size: 16px;\" data-start=\"4117\" data-end=\"4138\">Frakturstelle<\/strong><span style=\"font-size: 16px;\"> am vorderen Ende.<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04ee823 elementor-widget elementor-widget-heading\" data-id=\"04ee823\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Anforderungen an die Ergebnisberichterstattung nach ISO 11040-4<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9a8c95c elementor-widget elementor-widget-text-editor\" data-id=\"9a8c95c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4216\" data-end=\"4286\">Jeder Test muss ausf\u00fchrlich dokumentiert werden, einschlie\u00dflich der folgenden Daten:<\/p><ul><li data-start=\"4289\" data-end=\"4313\"><strong data-start=\"4289\" data-end=\"4303\">Testgeschwindigkeit<\/strong> in mm\/min<\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4316\" data-end=\"4349\">Abstand von der Spritzenspitze<\/strong><span style=\"font-size: 16px;\"> bei der die Kraft aufgebracht wurde<\/span><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4383\" data-end=\"4409\">Maximale Bruchkraft<\/strong><span style=\"font-size: 16px;\"> in Newton (N)<\/span><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4427\" data-end=\"4446\">Menge der Proben<\/strong><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4449\" data-end=\"4480\">Anomalien oder Abweichungen<\/strong><span style=\"font-size: 16px;\"> aus dem Verfahren<\/span><\/li><\/ul><p class=\"\" data-start=\"4501\" data-end=\"4652\">Dieser Detaillierungsgrad gew\u00e4hrleistet Konsistenz und erm\u00f6glicht die R\u00fcckverfolgbarkeit, insbesondere bei der Validierung neuer Spritzendesigns oder bei routinem\u00e4\u00dfigen Qualit\u00e4tspr\u00fcfungen.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c3b5bb elementor-widget elementor-widget-heading\" data-id=\"5c3b5bb\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Warum Cell Instruments f\u00fcr die Spritzenpr\u00fcfung w\u00e4hlen?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7471474 elementor-widget elementor-widget-text-editor\" data-id=\"7471474\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4659\" data-end=\"5243\">Mit jahrzehntelanger Erfahrung in <strong data-start=\"4744\" data-end=\"4779\">Materialpr\u00fcfung f\u00fcr medizinische Ger\u00e4te<\/strong>, <strong data-start=\"4781\" data-end=\"4801\">Zelle Instrumente<\/strong> bietet hochmoderne, auf die ISO- und ASTM-Normen zugeschnittene Pr\u00fcfl\u00f6sungen. Unser <strong>Spritzenpr\u00fcfger\u00e4t<\/strong> wurde speziell entwickelt, um eine Vielzahl von <strong data-start=\"4971\" data-end=\"4990\">Spritzenversuch<\/strong> Methoden, einschlie\u00dflich <strong data-start=\"5010\" data-end=\"5043\">Luer-Kegel-Bruchfestigkeit<\/strong>. Egal, ob Sie in der Produktion, in der Forschung oder in der Verifizierung durch Dritte t\u00e4tig sind, Cell Instruments bietet Ihnen ma\u00dfgeschneiderte L\u00f6sungen, die Integration von Automatisierungsl\u00f6sungen und umfassenden Support, um Ihre Pr\u00fcfanforderungen zu erf\u00fcllen.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-02c15b6 elementor-widget elementor-widget-text-editor\" data-id=\"02c15b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"5250\" data-end=\"5668\">Durchf\u00fchren <strong data-start=\"5278\" data-end=\"5311\">Luer-Kegel-Bruchfestigkeit<\/strong> Pr\u00fcfungen nach den Richtlinien <strong data-start=\"5337\" data-end=\"5361\"><a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> Anhang C2<\/strong> ist f\u00fcr die Gew\u00e4hrleistung der mechanischen Unversehrtheit der Spritzenkomponenten unerl\u00e4sslich. Durch den Einsatz pr\u00e4ziser Ger\u00e4te wie dem <strong>Spritzenpr\u00fcfger\u00e4t<\/strong>und die schrittweise Befolgung des von der ISO vorgeschriebenen Verfahrens k\u00f6nnen Sie die Produktqualit\u00e4t zuverl\u00e4ssig \u00fcberpr\u00fcfen, die Einhaltung der Vorschriften gew\u00e4hrleisten und die Sicherheit der Patienten sch\u00fctzen.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3344b6 elementor-widget elementor-widget-text-editor\" data-id=\"a3344b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"5420\" data-end=\"5503\"><strong data-start=\"5675\" data-end=\"5746\">Suchen Sie nach L\u00f6sungen f\u00fcr Spritzenpr\u00fcfungen, die der ISO 11040-4 entsprechen?<\/strong><\/p><p class=\"\" data-start=\"5420\" data-end=\"5503\">Kontakt <strong data-start=\"5757\" data-end=\"5787\">Cell Instruments Co, Ltd.<\/strong> um fachkundige Beratung und ma\u00dfgeschneiderte Pr\u00fcfsysteme f\u00fcr Ihre Anforderungen an die Qualit\u00e4tssicherung von Spritzen zu erhalten.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Cone Breakage Resistance ISO 11040-4 Annex C2 In syringe manufacturing and quality control, one of the most critical mechanical assessments is the luer cone breakage resistance test. The structural integrity of the syringe front end, especially the luer cone, directly impacts both patient safety and device reliability. To ensure consistent, standardized evaluation, the ISO [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2073","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/de\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Luer Cone Breakage Resistance ISO 11040-4 Annex C2 In syringe manufacturing and quality control, one of the most critical mechanical assessments is the luer cone breakage resistance test. The structural integrity of the syringe front end, especially the luer cone, directly impacts both patient safety and device reliability. To ensure consistent, standardized evaluation, the ISO&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/posts\/2073","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/comments?post=2073"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/posts\/2073\/revisions"}],"predecessor-version":[{"id":2084,"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/posts\/2073\/revisions\/2084"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/media?parent=2073"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/categories?post=2073"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/de\/wp-json\/wp\/v2\/tags?post=2073"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}