{"id":2429,"date":"2025-11-06T07:49:46","date_gmt":"2025-11-06T07:49:46","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2429"},"modified":"2025-11-06T07:55:39","modified_gmt":"2025-11-06T07:55:39","slug":"iso-9626","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/da\/iso-9626\/","title":{"rendered":"ISO 9626"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2429\" class=\"elementor elementor-2429\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5aa439d7 e-flex e-con-boxed e-con e-parent\" data-id=\"5aa439d7\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-442ef7 elementor-widget elementor-widget-text-editor\" data-id=\"442ef7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<!-- wp:heading -->\n<h2 class=\"wp-block-heading\"><\/h2>\n<!-- \/wp:heading -->\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-8d2ddaa e-flex e-con-boxed e-con e-parent\" data-id=\"8d2ddaa\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a1da949 elementor-widget elementor-widget-heading\" data-id=\"a1da949\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 9626 <br><small><small>Test af n\u00e5leslanger i rustfrit st\u00e5l<\/small><\/small><\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-28c31c0 e-con-full e-flex e-con e-child\" data-id=\"28c31c0\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b07c887 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"b07c887\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"463\" data-end=\"992\"><strong data-start=\"463\" data-end=\"475\">ISO 9626<\/strong> specificerer kravene og <strong data-start=\"507\" data-end=\"557\">testmetoder for n\u00e5leslanger af rustfrit st\u00e5l<\/strong> der anvendes til fremstilling af medicinsk udstyr som f.eks. injektionsn\u00e5le og kanyler. Denne internationale standard sikrer, at de slanger, der bruges til medicinske form\u00e5l, opfylder ensartede krav til ydeevne og sikkerhed. To vigtige tests under ISO 9626 er <strong data-start=\"814\" data-end=\"842\">Stivhedstest af slanger<\/strong> og den <strong data-start=\"851\" data-end=\"892\">Slangens modstandsdygtighed over for brudtest<\/strong>som er afg\u00f8rende for at vurdere den mekaniske integritet og holdbarhed af r\u00f8r af rustfrit st\u00e5l.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-34234b5 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"34234b5\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/11\/ISO-9626---Stainless-Steel-Needle-Tubing-Stiffness-and-Break-Strength-Testing.webp\" class=\"attachment-full size-full wp-image-2435\" alt=\"ISO 9626 - Test af stivhed og brudstyrke for n\u00e5leslanger i rustfrit st\u00e5l\" srcset=\"\" sizes=\"(max-width: 600px) 100vw, 600px\" data-srcset=\"\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0df13d1 elementor-widget elementor-widget-heading\" data-id=\"0df13d1\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hvad er ISO 9626?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-185e4a4 elementor-widget elementor-widget-text-editor\" data-id=\"185e4a4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1106\" data-end=\"1422\">ISO 9626-standarden, fuld titel <em data-start=\"1346\" data-end=\"1450\">\"N\u00e5leslanger af rustfrit st\u00e5l til fremstilling af medicinsk udstyr - Krav og pr\u00f8vningsmetoder\"<\/em>g\u00e6lder for <strong data-start=\"1463\" data-end=\"1502\">Stive n\u00e5leslanger i rustfrit st\u00e5l<\/strong> egnet til fremstilling af hypodermiske n\u00e5le og andre komponenter til medicinsk udstyr.<\/p>\n<p data-start=\"1283\" data-end=\"1620\">ISO 9626 spiller en afg\u00f8rende rolle i at sikre, at slanger af rustfrit st\u00e5l, der bruges til medicinske n\u00e5le, har tilstr\u00e6kkelig <strong data-start=\"1393\" data-end=\"1416\">mekanisk styrke<\/strong>, <strong data-start=\"1418\" data-end=\"1433\">fleksibilitet<\/strong>og <strong data-start=\"1439\" data-end=\"1464\">modstandsdygtighed over for tr\u00e6thed<\/strong>. Slanger, der ikke opfylder disse krav, kan resultere i, at n\u00e5len b\u00f8jes eller kn\u00e6kker under brug, hvilket udg\u00f8r en risiko for patienter og sundhedspersonale.<\/p>\n<p data-start=\"1622\" data-end=\"1645\">Standarden definerer:<\/p>\n<ul>\n<li data-start=\"1648\" data-end=\"1705\"><strong data-start=\"1648\" data-end=\"1675\">Specifikationer for materialer<\/strong> til r\u00f8r af rustfrit st\u00e5l.<\/li>\n<li data-start=\"1708\" data-end=\"1775\"><strong data-start=\"1708\" data-end=\"1734\">Dimensionelle tolerancer<\/strong> herunder v\u00e6gtykkelse og diameter.<\/li>\n<li data-start=\"1778\" data-end=\"1853\"><strong data-start=\"1778\" data-end=\"1807\">Test af mekaniske egenskaber<\/strong>som f.eks. stivhed og brudstyrke.<\/li>\n<\/ul>\n<p data-start=\"1855\" data-end=\"1991\">Overholdelse af ISO 9626 hj\u00e6lper producenterne med at opretholde en ensartet produktkvalitet og overholde internationale regler for medicinsk udstyr.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-304c484 elementor-widget elementor-widget-heading\" data-id=\"304c484\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<p class=\"elementor-heading-title elementor-size-default\">N\u00e5r man vurderer slanger til medicinsk udstyr, er der is\u00e6r to aspekter af den mekaniske ydeevne, der er vigtige:<\/p>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a08344a elementor-widget elementor-widget-heading\" data-id=\"a08344a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Test af r\u00f8rets stivhed<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8605095 elementor-widget elementor-widget-text-editor\" data-id=\"8605095\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2030\" data-end=\"2392\">Den <strong data-start=\"2034\" data-end=\"2062\">Stivhedstest af slanger<\/strong> evaluerer, hvor modstandsdygtige n\u00e5leslanger af rustfrit st\u00e5l er over for deformation, n\u00e5r de uds\u00e6ttes for en kraft. I henhold til ISO 9626 Annex B indeb\u00e6rer testen, at en specificeret l\u00e6ngde af slangen underst\u00f8ttes i begge ender, og at der p\u00e5f\u00f8res en kendt kraft. <strong data-start=\"2287\" data-end=\"2319\">nedadg\u00e5ende kraft i dens centrum<\/strong>. M\u00e6ngden af <strong data-start=\"2335\" data-end=\"2349\">afb\u00f8jning<\/strong> m\u00e5les derefter for at bestemme stivheden.<\/p>\n<p data-start=\"2394\" data-end=\"2540\">Denne test giver indsigt i, hvor meget slangen vil b\u00f8je under belastning - en vigtig faktor for at sikre, at <strong data-start=\"2498\" data-end=\"2537\">n\u00e5lens stabilitet under indf\u00f8ring<\/strong>.<\/p>\n<h4 data-start=\"2542\" data-end=\"2567\">Oversigt over procedurer<\/h4>\n<ol data-start=\"2568\" data-end=\"2856\">\n<li data-start=\"2568\" data-end=\"2669\">\n<p data-start=\"2571\" data-end=\"2669\">Slangen er placeret p\u00e5 en <strong data-start=\"2597\" data-end=\"2628\">Apparat til test af stivhed<\/strong> med et defineret sp\u00e6nd baseret p\u00e5 dens st\u00f8rrelse.<\/p>\n<\/li>\n<li data-start=\"2670\" data-end=\"2768\">\n<p data-start=\"2673\" data-end=\"2768\">A <strong data-start=\"2675\" data-end=\"2694\">Ladestempel<\/strong> p\u00e5f\u00f8rer en nedadg\u00e5ende kraft med en hastighed mellem <strong data-start=\"2739\" data-end=\"2765\">1 mm\/min og 10 mm\/min<\/strong>.<\/p>\n<\/li>\n<li data-start=\"2769\" data-end=\"2856\">\n<p data-start=\"2772\" data-end=\"2856\">Den <strong data-start=\"2776\" data-end=\"2790\">afb\u00f8jning<\/strong> ved p\u00e5l\u00e6sningsstedet registreres til n\u00e6rmeste <strong data-start=\"2842\" data-end=\"2853\">0,01 mm<\/strong>.<\/p>\n<\/li>\n<\/ol>\n<p data-start=\"2858\" data-end=\"3058\">H\u00f8jere stivhed indikerer st\u00e6rkere slanger, der modst\u00e5r b\u00f8jning, mens lavere stivhed kan indikere \u00f8get fleksibilitet. Begge egenskaber er vigtige afh\u00e6ngigt af den p\u00e5t\u00e6nkte medicinske anvendelse.<\/p>\n<p data-start=\"3060\" data-end=\"3349\"><strong data-start=\"3060\" data-end=\"3098\">Cell Instruments' stivhedstester<\/strong> tilbyder et pr\u00e6cisionskontrolleret belastningssystem og digital forskydningsm\u00e5ling, der er i fuld overensstemmelse med ISO 9626-kravene. Det giver laboratorier mulighed for at udf\u00f8re <strong data-start=\"3260\" data-end=\"3309\">stivhedstest af n\u00e5leslanger i rustfrit st\u00e5l<\/strong> med h\u00f8j n\u00f8jagtighed og repeterbarhed.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80ffe02 elementor-widget elementor-widget-heading\" data-id=\"80ffe02\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Slangens modstandsdygtighed over for brud<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24288c0 elementor-widget elementor-widget-text-editor\" data-id=\"24288c0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3396\" data-end=\"3665\">Den <strong data-start=\"3400\" data-end=\"3441\">Slangens modstandsdygtighed over for brudtest<\/strong> (ISO 9626 Annex C) evaluerer slangens evne til at modst\u00e5 gentagne b\u00f8jninger uden at revne eller kn\u00e6kke. Dette simulerer forhold i den virkelige verden, hvor en n\u00e5l kan blive udsat for cykliske belastninger under h\u00e5ndtering eller brug.<\/p>\n<h4 data-start=\"3667\" data-end=\"3688\">Testprincip<\/h4>\n<p data-start=\"3689\" data-end=\"4019\">Den ene ende af slangen er stift fastgjort, og en <strong data-start=\"3735\" data-end=\"3761\">gentagen b\u00f8jningskraft<\/strong> p\u00e5f\u00f8res i en bestemt afstand. Slangen b\u00f8jes skiftevis i modsatte retninger gennem en defineret vinkel - typisk <strong data-start=\"3887\" data-end=\"3920\">25\u00b0 for slanger med almindelig v\u00e6g<\/strong>, <strong data-start=\"3922\" data-end=\"3945\">20\u00b0 for tyndv\u00e6ggede<\/strong>og <strong data-start=\"3951\" data-end=\"3987\">15\u00b0 til ultratyndv\u00e6ggede slanger<\/strong> - for <strong data-start=\"3994\" data-end=\"4016\">20 komplette cyklusser<\/strong>.<\/p>\n<p data-start=\"4021\" data-end=\"4096\">Efter testen unders\u00f8ges slangen visuelt for eventuelle tegn p\u00e5 brud.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-54ef89d e-flex e-con-boxed e-con e-child\" data-id=\"54ef89d\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d72668b elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"d72668b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p><strong data-start=\"4098\" data-end=\"4143\">Cell Instruments' <a href=\"https:\/\/www.pharmacopoeiatest.com\/da\/medical-needle-break-resistance-tester\/\" target=\"_blank\" rel=\"noopener\" data-wplink-edit=\"true\">Test af brudmodstand<\/a><\/strong> har programmerbar cyklisk bev\u00e6gelseskontrol og et pr\u00e6cist vinkelforskydningssystem, der muligg\u00f8r n\u00f8jagtig evaluering af slangens <strong data-start=\"4276\" data-end=\"4298\">Udmattelsesmodstand<\/strong> og <strong data-start=\"4303\" data-end=\"4317\">holdbarhed<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d56cba elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"5d56cba\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.pharmacopoeiatest.com\/da\/medical-needle-break-resistance-tester\/\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester.webp\" class=\"attachment-large size-large wp-image-1924\" alt=\"Modstandstester til medicinsk n\u00e5lebrud\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester.webp 1000w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester-300x300.webp 300w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester-150x150.webp 150w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/02\/Medical-Needle-Break-Resistance-Tester-768x768.webp 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7bc2f44 elementor-widget elementor-widget-heading\" data-id=\"7bc2f44\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ofte stillede sp\u00f8rgsm\u00e5l<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d7e535a elementor-widget elementor-widget-toggle\" data-id=\"d7e535a\" data-element_type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2261\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-2261\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Q1: Hvad er ISO 9626?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2261\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-2261\"><p data-start=\"5213\" data-end=\"5511\"><strong data-start=\"5241\" data-end=\"5247\">A:<\/strong> <a href=\"https:\/\/www.iso.org\/standard\/60480.html\" target=\"_blank\" rel=\"noopener\">ISO 9626<\/a> er en international standard, der specificerer krav og testmetoder for <strong data-start=\"5335\" data-end=\"5368\">n\u00e5leslanger i rustfrit st\u00e5l<\/strong> der bruges til fremstilling af medicinsk udstyr. Den definerer parametre for dimensioner, stivhed, brudstyrke og generel mekanisk ydeevne.<\/p>\n<p data-start=\"5513\" data-end=\"5787\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2262\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-2262\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Sp\u00f8rgsm\u00e5l 2: Hvorfor er stivheden af slanger vigtig?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2262\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-2262\"><p data-start=\"5513\" data-end=\"5787\"><strong data-start=\"5570\" data-end=\"5576\">A:<\/strong> Den <strong data-start=\"5581\" data-end=\"5609\">Stivhedstest af slanger<\/strong> sikrer, at slangen bevarer tilstr\u00e6kkelig stivhed og ikke b\u00f8jer for meget under belastning. Det er afg\u00f8rende for stabiliteten og pr\u00e6cisionen af medicinske n\u00e5le under indf\u00f8ring.<\/p>\n<p data-start=\"5789\" data-end=\"6071\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2263\" class=\"elementor-tab-title\" data-tab=\"3\" role=\"button\" aria-controls=\"elementor-tab-content-2263\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Sp\u00f8rgsm\u00e5l 3: Hvad evaluerer testen af slangers modstandsdygtighed over for brud?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2263\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"region\" aria-labelledby=\"elementor-tab-title-2263\"><p data-start=\"5789\" data-end=\"6071\"><strong data-start=\"5861\" data-end=\"5867\">A:<\/strong> Denne test m\u00e5ler slangens evne til at modst\u00e5 <strong data-start=\"5921\" data-end=\"5948\">gentagne b\u00f8jningscyklusser<\/strong> uden at revne. Det er med til at bekr\u00e6fte holdbarheden og sikkerheden ved medicinske slanger af rustfrit st\u00e5l i kliniske anvendelser.<\/p>\n<p data-start=\"6073\" data-end=\"6350\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2264\" class=\"elementor-tab-title\" data-tab=\"4\" role=\"button\" aria-controls=\"elementor-tab-content-2264\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Q4: Hvilket udstyr kan udf\u00f8re ISO 9626-test?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2264\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"region\" aria-labelledby=\"elementor-tab-title-2264\"><p data-start=\"6073\" data-end=\"6350\"><strong data-start=\"6129\" data-end=\"6135\">A:<\/strong> <strong data-start=\"6136\" data-end=\"6202\">Cell Instruments' stivhedstester og brudmodstandstester<\/strong> er specielt designet til at udf\u00f8re ISO 9626-kompatible tests og tilbyder pr\u00e6cis kraftkontrol, automatiseret m\u00e5ling og p\u00e5lidelig repeterbarhed.<\/p>\n<p data-start=\"6352\" data-end=\"6632\">\u00a0<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2265\" class=\"elementor-tab-title\" data-tab=\"5\" role=\"button\" aria-controls=\"elementor-tab-content-2265\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">Q5: Hvem b\u00f8r udf\u00f8re ISO 9626-tests?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2265\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"5\" role=\"region\" aria-labelledby=\"elementor-tab-title-2265\"><p data-start=\"6352\" data-end=\"6632\"><strong data-start=\"6397\" data-end=\"6403\">A:<\/strong> Kvalitetskontrolingeni\u00f8rer, laboratorieteknikere og producenter af medicinsk udstyr, der producerer eller validerer <strong data-start=\"6512\" data-end=\"6545\">n\u00e5leslanger i rustfrit st\u00e5l<\/strong> b\u00f8r udf\u00f8re disse tests for at sikre overensstemmelse med internationale sikkerhedsstandarder.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 9626 Test af n\u00e5leslanger i rustfrit st\u00e5l ISO 9626 specificerer krav og testmetoder for n\u00e5leslanger i rustfrit st\u00e5l, der bruges til fremstilling af medicinsk udstyr som f.eks. injektionsn\u00e5le og kanyler. Denne internationale standard sikrer, at de slanger, der bruges i medicinske applikationer, opfylder ensartede krav til ydeevne og sikkerhed. To vigtige tests under ISO [...]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2429","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/da\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 9626 Stainless Steel Needle Tubing Test ISO 9626 specifies the requirements and test methods for stainless steel needle tubing used in the manufacture of medical devices such as hypodermic needles and cannulas. This international standard ensures that the tubing used in medical applications meets consistent performance and safety requirements. Two key tests under ISO&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/posts\/2429","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/comments?post=2429"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/posts\/2429\/revisions"}],"predecessor-version":[{"id":2445,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/posts\/2429\/revisions\/2445"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/media?parent=2429"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/categories?post=2429"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/tags?post=2429"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}