{"id":2197,"date":"2025-06-24T02:14:04","date_gmt":"2025-06-24T02:14:04","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2197"},"modified":"2025-06-24T02:18:12","modified_gmt":"2025-06-24T02:18:12","slug":"iso-7864","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/da\/iso-7864\/","title":{"rendered":"ISO 7864 Test af hypodermiske spr\u00f8jters funktionalitet"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2197\" class=\"elementor elementor-2197\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-66b560c e-flex e-con-boxed e-con e-parent\" data-id=\"66b560c\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-86c40f3 elementor-widget elementor-widget-heading\" data-id=\"86c40f3\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">ISO 7864 <br><small><small>Test af hypodermiske spr\u00f8jters funktionalitet<\/small><\/small><\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b5014aa e-con-full e-flex e-con e-child\" data-id=\"b5014aa\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-dea855d elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"dea855d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"398\" data-end=\"1099\">N\u00e5r det drejer sig om sterile kanyler, er patientsikkerhed og produktydelse ikke til forhandling. Det er derfor <strong data-start=\"534\" data-end=\"546\">ISO 7864<\/strong> spiller en afg\u00f8rende rolle. Denne internationale standard beskriver omfattende krav og testmetoder til at evaluere injektionskanyler for <strong data-start=\"683\" data-end=\"706\">Spr\u00f8jter til engangsbrug<\/strong>, herunder <strong data-start=\"718\" data-end=\"751\">Test af spr\u00f8jtens funktionalitet<\/strong>, <strong data-start=\"753\" data-end=\"787\">Metode til n\u00e5lepenetrationstest<\/strong>og <strong data-start=\"793\" data-end=\"820\">Styrke af n\u00e5lebinding<\/strong>. Producenter, kvalitetskontrolingeni\u00f8rer og tilsynsmyndigheder stoler p\u00e5 ISO 7864 for at sikre ensartet produktkvalitet og -sikkerhed.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7f53d82 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"7f53d82\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.pharmacopoeiatest.com\/da\/syringe-needle-penetration-test\/\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"400\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/ISO-7864-Hypodermic-Syringe-Functionality-Testing-1.webp\" class=\"attachment-full size-full wp-image-2200\" alt=\"ISO 7864 Test af hypodermiske spr\u00f8jters funktionalitet\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/ISO-7864-Hypodermic-Syringe-Functionality-Testing-1.webp 600w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/06\/ISO-7864-Hypodermic-Syringe-Functionality-Testing-1-300x200.webp 300w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-11bf196 elementor-widget elementor-widget-heading\" data-id=\"11bf196\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hvad er ISO 7864, og hvorfor er det vigtigt?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-edf0ed0 elementor-widget elementor-widget-text-editor\" data-id=\"edf0ed0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1106\" data-end=\"1422\"><strong data-start=\"1148\" data-end=\"1160\">ISO 7864<\/strong> er den <strong data-start=\"1168\" data-end=\"1225\">International standard for sterile injektionskanyler<\/strong> beregnet til engangsbrug med spr\u00f8jter eller infusionsudstyr. Den definerer n\u00e5lens fysiske krav, dimensioner, ydeevneegenskaber, emballering og <strong data-start=\"1390\" data-end=\"1406\">Testmetoder<\/strong> til at evaluere:<\/p><ul><li data-start=\"1426\" data-end=\"1445\"><strong data-start=\"1426\" data-end=\"1443\">Gennemtr\u00e6ngelighed<\/strong><\/li><li data-start=\"1448\" data-end=\"1470\"><strong data-start=\"1448\" data-end=\"1468\">Bindingsstyrke<\/strong><\/li><li data-start=\"1473\" data-end=\"1500\"><strong data-start=\"1473\" data-end=\"1498\">N\u00e5leslangens integritet<\/strong><\/li><li data-start=\"1503\" data-end=\"1529\"><strong data-start=\"1503\" data-end=\"1527\">Modstandsdygtighed over for korrosion<\/strong><\/li><li data-start=\"1532\" data-end=\"1557\"><strong data-start=\"1532\" data-end=\"1557\">Kompatibilitet med spr\u00f8jter<\/strong><\/li><\/ul><p data-start=\"1559\" data-end=\"1707\">Overholdelse af ISO 7864 sikrer, at kanyler fungerer p\u00e5lideligt under kliniske forhold, hvilket reducerer risikoen for b\u00e5de patienter og sundhedspersonale.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f659161 elementor-widget elementor-widget-heading\" data-id=\"f659161\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test af ISO-spr\u00f8jters funktionalitet<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c1eb6db elementor-widget elementor-widget-text-editor\" data-id=\"c1eb6db\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"1714\" data-end=\"1946\"><strong data-start=\"1782\" data-end=\"1815\">Test af spr\u00f8jtens funktionalitet<\/strong> sikrer, at n\u00e5len er kompatibel med den tilh\u00f8rende spr\u00f8jte og fungerer effektivt under indspr\u00f8jtningen. De testede parametre omfatter:<\/p><ul><li data-start=\"1950\" data-end=\"1990\"><strong data-start=\"1950\" data-end=\"1988\">Kompatibilitet med Luer-stik<\/strong><\/li><li data-start=\"1993\" data-end=\"2012\"><strong data-start=\"1993\" data-end=\"2010\">Stempelkraft<\/strong><\/li><li data-start=\"2015\" data-end=\"2048\"><strong data-start=\"2015\" data-end=\"2046\">Injektionskraftens konsistens<\/strong><\/li><li data-start=\"2051\" data-end=\"2078\"><strong data-start=\"2051\" data-end=\"2078\">Minimering af d\u00f8d plads<\/strong><\/li><\/ul><p data-start=\"2080\" data-end=\"2309\">Disse evalueringer er afg\u00f8rende for en <strong data-start=\"2118\" data-end=\"2133\">ISO-spr\u00f8jte<\/strong> for at best\u00e5 certificeringen. Cell Instruments leverer l\u00f8sninger, der vurderer funktionaliteten ved at m\u00e5le indf\u00f8ringskraft, stempelmodstand og kraftfordeling under injektion.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-64b918a elementor-widget elementor-widget-heading\" data-id=\"64b918a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Test af n\u00e5lens gennemtr\u00e6ngelighed<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7baacfb elementor-widget elementor-widget-text-editor\" data-id=\"7baacfb\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"2316\" data-end=\"2506\">En af de vigtigste test under ISO 7864 er <strong data-start=\"2429\" data-end=\"2463\">Metode til n\u00e5lepenetrationstest<\/strong>ogs\u00e5 kendt som <strong data-start=\"2483\" data-end=\"2505\">Test af gennemtr\u00e6ngelighed<\/strong>.<\/p><p data-start=\"2508\" data-end=\"2747\"><strong data-start=\"2508\" data-end=\"2526\">Testprincip<\/strong><br data-start=\"2526\" data-end=\"2529\" \/>En n\u00e5l stikkes ind i en standardiseret <strong data-start=\"2570\" data-end=\"2583\">Substrat<\/strong> ved en konstant hastighed (typisk 100 mm\/min). Den <strong data-start=\"2632\" data-end=\"2658\">maksimal indtr\u00e6ngningskraft<\/strong> og <strong data-start=\"2663\" data-end=\"2677\">Modstandskraft<\/strong> registreres for at evaluere let gennemtr\u00e6ngning og ensartet bev\u00e6gelse.<\/p><p data-start=\"2749\" data-end=\"2768\"><strong data-start=\"2749\" data-end=\"2766\">Vigtigt udstyr<\/strong><\/p><ul><li data-start=\"2771\" data-end=\"2826\">Kraftm\u00e5lingssystem med pr\u00e6cision <strong data-start=\"2811\" data-end=\"2824\">Vejecelle<\/strong><\/li><li data-start=\"2829\" data-end=\"2865\">Kanyleholder med aksial justering<\/li><li data-start=\"2868\" data-end=\"2918\">Valideret substrat (f.eks. latexgummi eller LDPE)<\/li><li data-start=\"2921\" data-end=\"2979\">Penetrationsdybdem\u00e5ler (typisk 80% af n\u00e5lens l\u00e6ngde)<\/li><\/ul><p data-start=\"2981\" data-end=\"3175\"><strong data-start=\"2981\" data-end=\"3001\">Cell-instrumenter<\/strong> Tilbud <strong data-start=\"3009\" data-end=\"3049\">automatiseret n\u00e5lepenetrationstester<\/strong>\u00a0med programmerbare hastigheder og digital kraftanalyse for at sikre n\u00f8jagtighed og repeterbarhed i overensstemmelse med ISO 7864 Annex D.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-46d372b elementor-widget elementor-widget-heading\" data-id=\"46d372b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Modstandskraft og maksimal gennemtr\u00e6ngningskraft<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b565e71 elementor-widget elementor-widget-text-editor\" data-id=\"b565e71\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3182\" data-end=\"3269\">Der udledes to hovedresultater:<\/p><ul><li data-start=\"3273\" data-end=\"3345\"><strong data-start=\"3273\" data-end=\"3300\">Maksimal gennemtr\u00e6ngningskraft:<\/strong> Maksimal kraft, der kr\u00e6ves for at gennembore underlaget<\/li><li data-start=\"3348\" data-end=\"3436\"><strong data-start=\"3348\" data-end=\"3363\">Modstandskraft:<\/strong> Gennemsnitlig kraft n\u00f8dvendig for at opretholde penetration over 80% af n\u00e5lens l\u00e6ngde<\/li><\/ul><p data-start=\"3438\" data-end=\"3600\">Disse m\u00e5linger afspejler n\u00e5lens skarphed, friktion og ensartethed i produktionen. Pr\u00e6cis m\u00e5ling er afg\u00f8rende i forbindelse med myndighedsans\u00f8gninger og designvalidering.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c892b5 elementor-widget elementor-widget-heading\" data-id=\"5c892b5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Styrke af n\u00e5lebindingstest<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-30d6b5b elementor-widget elementor-widget-text-editor\" data-id=\"30d6b5b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3607\" data-end=\"3825\">Bindingsstyrke refererer til <strong data-start=\"3697\" data-end=\"3745\">vedh\u00e6ftning mellem kanyler\u00f8ret og navet<\/strong>-En svag binding kan f\u00f8re til l\u00f8srivelse under injektion, hvilket udg\u00f8r en alvorlig fare.<\/p><p data-start=\"3827\" data-end=\"3870\"><strong data-start=\"3827\" data-end=\"3868\">Testprocedure (ISO 7864 bilag E):<\/strong><\/p><ul><li data-start=\"3873\" data-end=\"3938\">N\u00e5len gribes lodret p\u00e5 en <strong data-start=\"3907\" data-end=\"3936\">Universal testmaskine<\/strong><\/li><li data-start=\"3941\" data-end=\"3986\">A <strong data-start=\"3943\" data-end=\"3960\">Tr\u00e6kstyrke<\/strong> p\u00e5f\u00f8res med 50 mm\/min<\/li><li data-start=\"3989\" data-end=\"4062\">Den <strong data-start=\"3993\" data-end=\"4010\">maksimal kraft<\/strong> hvor l\u00f8srivelsen eller fejlen opst\u00e5r, registreres<\/li><\/ul><p data-start=\"4064\" data-end=\"4223\"><strong data-start=\"4064\" data-end=\"4084\">Cell-instrumenter<\/strong> giver <strong data-start=\"4094\" data-end=\"4123\">Universal tr\u00e6kpr\u00f8vemaskine<\/strong>\u00a0med tilpassede armaturer til <strong data-start=\"4153\" data-end=\"4177\">Test af n\u00e5lebinding<\/strong>og sikre overholdelse af bilag E-procedurer.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-94ab6f1 elementor-widget elementor-widget-heading\" data-id=\"94ab6f1\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Cell Instruments overholdelse af ISO 7864 <\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-603c5c9 elementor-widget elementor-widget-text-editor\" data-id=\"603c5c9\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"4230\" data-end=\"4393\">Cell Instruments har specialiseret sig i <strong data-start=\"4318\" data-end=\"4349\">l\u00f8sninger til pr\u00e6cisionstest<\/strong> for producenter af medicinsk udstyr, der tilbyder:<\/p><ul><li data-start=\"4397\" data-end=\"4427\">Test af n\u00e5lens gennemtr\u00e6ngelighed<\/li><li data-start=\"4430\" data-end=\"4463\">Universal limstyrke-tester<\/li><li data-start=\"4466\" data-end=\"4505\">Systemer til test af spr\u00f8jtefunktionalitet<\/li><li data-start=\"4508\" data-end=\"4576\">Tilpassede armaturer til Luer lock-kompatibilitet og kanyleholder<\/li><li data-start=\"4579\" data-end=\"4637\">Opgraderinger af automatisering til <strong data-start=\"4603\" data-end=\"4635\">Repeterbarhed og gennemstr\u00f8mning<\/strong><\/li><\/ul><p data-start=\"4639\" data-end=\"4842\">Alle instrumenter er bygget til at passe til <strong data-start=\"4679\" data-end=\"4691\">ISO 7864<\/strong>, <strong data-start=\"4693\" data-end=\"4705\">ISO 8537<\/strong>, <a href=\"https:\/\/www.pharmacopoeiatest.com\/da\/iso-7886-1\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"4707\" data-end=\"4719\">ISO 7886<\/strong><\/a>og <strong data-start=\"4725\" data-end=\"4736\">USP 381<\/strong> standarder. Vores systemer underst\u00f8tter statistisk analyse, dataeksport og sporbare kalibreringscertifikater.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0546b7e elementor-widget elementor-widget-heading\" data-id=\"0546b7e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Ofte stillede sp\u00f8rgsm\u00e5l<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f3b149b elementor-widget elementor-widget-toggle\" data-id=\"f3b149b\" data-element_type=\"widget\" data-widget_type=\"toggle.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-toggle\">\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2551\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-2551\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">1. Hvad er ISO 7864?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2551\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-2551\"><p data-start=\"5830\" data-end=\"6017\"><a href=\"https:\/\/www.iso.org\/standard\/60481.html\" target=\"_blank\" rel=\"noopener\">ISO 7864<\/a> Specificerer krav og testmetoder for sterile injektionskanyler til engangsbrug. Den d\u00e6kker fysiske dimensioner, materialer og pr\u00e6stationstest.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2552\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-2552\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">2. Hvad indeb\u00e6rer test af spr\u00f8jtens funktionalitet?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2552\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-2552\"><p data-start=\"6019\" data-end=\"6226\">Den evaluerer samspillet mellem spr\u00f8jte og n\u00e5l, herunder injektionskraft, forsegling og brugervenlighed for at sikre ensartet og sikker drift.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2553\" class=\"elementor-tab-title\" data-tab=\"3\" role=\"button\" aria-controls=\"elementor-tab-content-2553\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">3. Hvordan udf\u00f8res gennemtr\u00e6ngelighedstesten?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2553\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"region\" aria-labelledby=\"elementor-tab-title-2553\"><p data-start=\"6228\" data-end=\"6415\">En n\u00e5l f\u00f8res ind i et standardiseret materiale med en hastighed p\u00e5 100 mm\/min. Spidsbelastning og modstandskraft registreres for at evaluere skarphed og ydeevne.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2554\" class=\"elementor-tab-title\" data-tab=\"4\" role=\"button\" aria-controls=\"elementor-tab-content-2554\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">4. Hvad m\u00e5ler man i n\u00e5lebindingstesten?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2554\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"region\" aria-labelledby=\"elementor-tab-title-2554\"><p data-start=\"6417\" data-end=\"6591\">Den tr\u00e6kkraft, der skal til for at l\u00f8sne n\u00e5len fra navet. Det verificerer mekanisk integritet under p\u00e5f\u00f8rt stress.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-toggle-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-2555\" class=\"elementor-tab-title\" data-tab=\"5\" role=\"button\" aria-controls=\"elementor-tab-content-2555\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon elementor-toggle-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-closed\"><svg class=\"e-font-icon-svg e-fas-caret-right\" viewbox=\"0 0 192 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M0 384.662V127.338c0-17.818 21.543-26.741 34.142-14.142l128.662 128.662c7.81 7.81 7.81 20.474 0 28.284L34.142 398.804C21.543 411.404 0 402.48 0 384.662z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-toggle-icon-opened\"><svg class=\"elementor-toggle-icon-opened e-font-icon-svg e-fas-caret-up\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M288.662 352H31.338c-17.818 0-26.741-21.543-14.142-34.142l128.662-128.662c7.81-7.81 20.474-7.81 28.284 0l128.662 128.662c12.6 12.599 3.676 34.142-14.142 34.142z\"><\/path><\/svg><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-toggle-title\" tabindex=\"0\">5. Hvilke instrumenter kan hj\u00e6lpe med at overholde ISO 7864?<\/a>\n\t\t\t\t\t<\/div>\n\n\t\t\t\t\t<div id=\"elementor-tab-content-2555\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"5\" role=\"region\" aria-labelledby=\"elementor-tab-title-2555\"><p data-start=\"6593\" data-end=\"6806\">Cell Instruments' automatiserede\u00a0<strong data-start=\"6683\" data-end=\"6708\">gennemtr\u00e6ngelighedstester<\/strong>\u00a0og\u00a0<strong data-start=\"6713\" data-end=\"6742\">Universal tr\u00e6kpr\u00f8vemaskine<\/strong>\u00a0er ideelle til evaluering af n\u00e5le og spr\u00f8jter i overensstemmelse med ISO 7864.<\/p><\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>ISO 7864 Hypodermic Syringe Functionality Testing When it comes to sterile hypodermic needles, patient safety and product performance are non-negotiable. That\u2019s where ISO 7864 plays a vital role. This international standard outlines comprehensive requirements and test methods to evaluate hypodermic needles for single-use syringes, including syringe functionality testing, needle penetration test method, and strength of [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[93,92],"class_list":["post-2197","post","type-post","status-publish","format-standard","hentry","category-blog","tag-iso-7864","tag-standards"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/da\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO 7864 Hypodermic Syringe Functionality Testing When it comes to sterile hypodermic needles, patient safety and product performance are non-negotiable. That\u2019s where ISO 7864 plays a vital role. This international standard outlines comprehensive requirements and test methods to evaluate hypodermic needles for single-use syringes, including syringe functionality testing, needle penetration test method, and strength of&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/posts\/2197","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/comments?post=2197"}],"version-history":[{"count":4,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/posts\/2197\/revisions"}],"predecessor-version":[{"id":2203,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/posts\/2197\/revisions\/2203"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/media?parent=2197"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/categories?post=2197"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/tags?post=2197"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}