{"id":2105,"date":"2025-05-07T06:56:33","date_gmt":"2025-05-07T06:56:33","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2105"},"modified":"2025-05-07T06:56:34","modified_gmt":"2025-05-07T06:56:34","slug":"lla-collar-torque-resistance","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/da\/lla-collar-torque-resistance\/","title":{"rendered":"LLA-halsb\u00e5ndets momentmodstand"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2105\" class=\"elementor elementor-2105\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3f46df2 e-flex e-con-boxed e-con e-parent\" data-id=\"3f46df2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7b2444a elementor-widget elementor-widget-heading\" data-id=\"7b2444a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">LLA-halsb\u00e5ndets momentmodstand<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8edec19 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"8edec19\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e4ea1f elementor-widget elementor-widget-heading\" data-id=\"0e4ea1f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Bilag G4<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3053d41 e-flex e-con-boxed e-con e-parent\" data-id=\"3053d41\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-7d4d20a elementor-widget elementor-widget-text-editor\" data-id=\"7d4d20a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"376\" data-end=\"978\">I den farmaceutiske produktion er det afg\u00f8rende for produktets sikkerhed og ydeevne, at de fyldte spr\u00f8jter er mekanisk intakte. En n\u00f8glefaktor i denne integritet er <strong data-start=\"567\" data-end=\"599\">LLA-kravens modstandsdygtighed over for drejningsmoment<\/strong>som m\u00e5ler styrken af Luer lock-adapterens (LLA) krave under drejningsmoment. Denne egenskab sikrer, at kraven kan modst\u00e5 rotationskraften, n\u00e5r medicinsk personale fastg\u00f8r kanylehubs eller kompatible konnektorer. Udf\u00f8relse af denne test i overensstemmelse med <em data-start=\"862\" data-end=\"875\">ISO 11040-4<\/em> og <em data-start=\"880\" data-end=\"890\">Bilag G4<\/em> hj\u00e6lper producenter med at overholde lovgivningen og levere sikre, funktionelle produkter.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0043965 elementor-widget elementor-widget-heading\" data-id=\"0043965\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">LLA-halsb\u00e5ndets momentmodstand, og det betyder noget<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef59016 elementor-widget elementor-widget-text-editor\" data-id=\"ef59016\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"985\" data-end=\"1456\"><strong data-start=\"1047\" data-end=\"1079\">LLA-kravens modstandsdygtighed over for drejningsmoment<\/strong> henviser til kapaciteten af Luer lock-adapterkraven p\u00e5 en spr\u00f8jte til at modst\u00e5 at dreje eller l\u00f8sne sig, n\u00e5r der p\u00e5f\u00f8res et moment. I den virkelige verden simulerer dette den mekaniske belastning, der ud\u00f8ves, n\u00e5r en kliniker tilslutter en Luer-lock-kompatibel enhed. Manglende momentmodstand kan f\u00f8re til l\u00e6kage, forkert l\u00e6gemiddeladministration eller kontaminering - alvorlige risici i kliniske omgivelser.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77afa8a elementor-widget elementor-widget-heading\" data-id=\"77afa8a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Standard for spr\u00f8jtetest - ISO 11040-4 Annex G4<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9f4cc74 e-con-full e-flex e-con e-child\" data-id=\"9f4cc74\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0879ad7 elementor-widget elementor-widget-text-editor\" data-id=\"0879ad7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1463\" data-end=\"1902\">Den <strong data-start=\"1525\" data-end=\"1540\">ISO 11040-4<\/strong> standard med titlen <em data-start=\"1558\" data-end=\"1673\">F\u00e6rdigfyldte spr\u00f8jter - Del 4: Glasbeholdere til injektionsv\u00e6sker og steriliserede, f\u00e6rdigsamlede spr\u00f8jter klar til fyldning<\/em>beskriver strenge testmetoder for at sikre produktets p\u00e5lidelighed. <em data-start=\"1737\" data-end=\"1747\">Bilag G4<\/em> beskriver specifikt metoden til at vurdere <strong data-start=\"1794\" data-end=\"1826\">LLA-kravens modstandsdygtighed over for drejningsmoment<\/strong>hvilket g\u00f8r den uundv\u00e6rlig for producenter, der er involveret i <strong data-start=\"1882\" data-end=\"1901\">Spr\u00f8jtetestning<\/strong>.<\/p><p class=\"\" data-start=\"1904\" data-end=\"1941\">De vigtigste h\u00f8jdepunkter fra Annex G4 omfatter:<\/p><ul><li data-start=\"1944\" data-end=\"2066\"><strong data-start=\"1944\" data-end=\"1963\">Testprincip:<\/strong> Kontrollerer, om LLA-kraven kan modst\u00e5 drejningsmoment under fastg\u00f8relse af en standard 6% Luer konisk fitting.<\/li><li data-start=\"2069\" data-end=\"2129\"><strong data-start=\"2069\" data-end=\"2099\">Anbefalet pr\u00f8veudtagningshastighed:<\/strong> 500 Hz til spidsbelastningsm\u00e5linger.<\/li><li data-start=\"2132\" data-end=\"2186\"><strong data-start=\"2132\" data-end=\"2160\">Standard rotationshastighed:<\/strong> 20 rpm eller som aftalt.<\/li><li data-start=\"2189\" data-end=\"2255\"><strong data-start=\"2189\" data-end=\"2212\">M\u00e5lingsoutput:<\/strong> H\u00f8jeste drejningsmoment ved p\u00e5begyndelse af kravens bev\u00e6gelse.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1ed627 elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"d1ed627\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"236\" height=\"361\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing.webp\" class=\"attachment-full size-full wp-image-2107\" alt=\"LLA-halsb\u00e5ndets momentmodstand - ISO 11040-4 spr\u00f8jtetest\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing.webp 236w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/05\/LLA-Collar-Torque-Resistance-ISO-11040-4-Syringe-Testing-196x300.webp 196w\" sizes=\"(max-width: 236px) 100vw, 236px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-47df98e elementor-widget elementor-widget-heading\" data-id=\"47df98e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testudstyr til LLA-halsb\u00e5ndets momentmodstand<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4baaf8e elementor-widget elementor-widget-text-editor\" data-id=\"4baaf8e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2262\" data-end=\"2400\">At udf\u00f8re testen kr\u00e6ver pr\u00e6cisionsinstrumenter. Standardops\u00e6tningen omfatter:<\/p><ul><li data-start=\"2403\" data-end=\"2556\"><strong data-start=\"2403\" data-end=\"2441\">Momenttester med rotationsanordning<\/strong>: Skal v\u00e6re i stand til at registrere spidsmoment med en opl\u00f8sning p\u00e5 <strong data-start=\"2507\" data-end=\"2519\">0,05 Ncm<\/strong>Det ideelle omr\u00e5de er <strong data-start=\"2539\" data-end=\"2555\">op til 35 Ncm<\/strong>.<\/li><li data-start=\"2559\" data-end=\"2630\"><strong data-start=\"2559\" data-end=\"2581\">LLA Krave Gripper<\/strong>: Fastsp\u00e6nder kraven sikkert uden at beskadige den.<\/li><li data-start=\"2633\" data-end=\"2737\"><strong data-start=\"2633\" data-end=\"2661\">Drejelig spr\u00f8jteholder<\/strong>: Giver mulighed for n\u00f8jagtig og ensartet rotation af spr\u00f8jten eller lukningen.<\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0058def elementor-widget elementor-widget-heading\" data-id=\"0058def\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Trin-for-trin-guide til at gennemf\u00f8re testen<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e82ef56 elementor-widget elementor-widget-text-editor\" data-id=\"e82ef56\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2938\" data-end=\"3119\">Professionelle inden for kvalitetskontrol kan f\u00f8lge disse trin for at sikre n\u00f8jagtig og standardiseret testning af <strong data-start=\"3086\" data-end=\"3118\">LLA-kravens modstandsdygtighed over for drejningsmoment<\/strong>:<\/p><ol><li data-start=\"3124\" data-end=\"3195\"><strong data-start=\"3124\" data-end=\"3134\">Inds\u00e6t<\/strong> den steriliserede, samlede spr\u00f8jte i spr\u00f8jteholderen.<\/li><li data-start=\"3199\" data-end=\"3231\"><strong data-start=\"3199\" data-end=\"3209\">Fjerne<\/strong> spidsd\u00e6kslet manuelt.<\/li><li data-start=\"3235\" data-end=\"3297\"><strong data-start=\"3235\" data-end=\"3244\">Bjerg<\/strong> LLA-kravens griber sikkert p\u00e5 LLA-kraven.<\/li><li data-start=\"3301\" data-end=\"3355\"><strong data-start=\"3301\" data-end=\"3309\">Nul<\/strong> momentcellen for at eliminere forsp\u00e6ndingsmomentet.<\/li><li data-start=\"3359\" data-end=\"3416\"><strong data-start=\"3359\" data-end=\"3366\">S\u00e6t<\/strong> Rotationshastigheden til 20 o\/min (eller efter behov).<\/li><li data-start=\"3420\" data-end=\"3509\"><strong data-start=\"3420\" data-end=\"3432\">Indled<\/strong> testen ved at dreje spr\u00f8jten eller proppen 90\u00b0 i den angivne retning.<\/li><li data-start=\"3513\" data-end=\"3568\"><strong data-start=\"3513\" data-end=\"3523\">Rekord<\/strong> det maksimale drejningsmoment, n\u00e5r kravens bev\u00e6gelse begynder.<\/li><\/ol><p class=\"\" data-start=\"3570\" data-end=\"3675\">Denne momentv\u00e6rdi afspejler <strong data-start=\"3601\" data-end=\"3623\">maksimal modstand<\/strong> der tilbydes af LLA-kraven under driftsstress.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-d445bbc e-con-full e-flex e-con e-child\" data-id=\"d445bbc\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-defbeb6 e-con-full e-flex e-con e-child\" data-id=\"defbeb6\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-1c54c92 elementor-widget elementor-widget-heading\" data-id=\"1c54c92\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testrapportering og kvalitetskontrol<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-669ef67 elementor-widget elementor-widget-text-editor\" data-id=\"669ef67\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"3682\" data-end=\"3799\">I henhold til ISO 11040-4 Annex G4 skal en omfattende testrapport indeholde:<\/p><ul><li data-start=\"3802\" data-end=\"3826\">V\u00e6rdier for h\u00f8jeste drejningsmoment (Ncm)<\/li><li data-start=\"3829\" data-end=\"3849\">Rotationshastighed (rpm)<\/li><li data-start=\"3852\" data-end=\"3876\">Antal testede pr\u00f8ver<\/li><li data-start=\"3879\" data-end=\"3896\">Best\u00e5ede\/ikke-best\u00e5ede resultater<\/li><li data-start=\"3899\" data-end=\"3931\">Noter om afvigelser eller uregelm\u00e6ssigheder<\/li><\/ul><p class=\"\" data-start=\"3933\" data-end=\"4059\">Denne dokumentation sikrer sporbarhed og overensstemmelse, som begge er afg\u00f8rende for regulatoriske audits og certificering af produktudgivelser.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-cb68c8a e-con-full e-flex e-con e-child\" data-id=\"cb68c8a\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c067893 elementor-widget elementor-widget-heading\" data-id=\"c067893\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Fordele ved automatiseret test af drejningsmoment<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-36ac35a elementor-widget elementor-widget-text-editor\" data-id=\"36ac35a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4066\" data-end=\"4277\">Hos Cell Instruments har vi specialiseret os i pr\u00e6cisionstestsystemer, herunder momenttestere, der er skr\u00e6ddersyet til <strong data-start=\"4211\" data-end=\"4243\">LLA-kravens modstandsdygtighed over for drejningsmoment<\/strong> evalueringer. Automatisering forbedrer:<\/p><ul><li data-start=\"4280\" data-end=\"4309\"><strong data-start=\"4280\" data-end=\"4309\">M\u00e5lingens repeterbarhed<\/strong><\/li><li data-start=\"4312\" data-end=\"4329\"><strong data-start=\"4312\" data-end=\"4329\">N\u00f8jagtighed i data<\/strong><\/li><li data-start=\"4332\" data-end=\"4358\"><strong data-start=\"4332\" data-end=\"4358\">Operationel effektivitet<\/strong><\/li><li data-start=\"4361\" data-end=\"4385\"><strong data-start=\"4361\" data-end=\"4385\">Sikring af overholdelse<\/strong><\/li><\/ul><p class=\"\" data-start=\"4387\" data-end=\"4527\">Tilpassede armaturer og softwareintegration g\u00f8r det muligt for laboratorier at str\u00f8mline arbejdsgange for spr\u00f8jtetestning og samtidig overholde ISO-retningslinjerne.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-11ccf92 elementor-widget elementor-widget-text-editor\" data-id=\"11ccf92\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4984\" data-end=\"5514\">Forst\u00e5else og implementering af <strong data-start=\"5036\" data-end=\"5068\">LLA-kravens modstandsdygtighed over for drejningsmoment<\/strong> test i overensstemmelse med <a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"5092\" data-end=\"5107\">ISO 11040-4<\/strong><\/a> og <strong data-start=\"5112\" data-end=\"5124\">Bilag G4<\/strong> er afg\u00f8rende for kvalitetssikring af spr\u00f8jter. Denne test beskytter mod mekanisk svigt under klinisk brug og hj\u00e6lper producenterne med at opretholde de h\u00f8jeste standarder for patientsikkerhed. P\u00e5 <strong data-start=\"5308\" data-end=\"5328\">Cell-instrumenter<\/strong>Vi leverer avancerede l\u00f8sninger til test af drejningsmoment, der er i overensstemmelse med globale standarder og branchens behov, og som giver spr\u00f8jteproducenter p\u00e5lidelige data og tillid til lovgivningen.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>LLA Collar Torque Resistance ISO 11040-4 Annex G4 In pharmaceutical manufacturing, ensuring the mechanical integrity of prefilled syringes is critical to product safety and performance. One key factor in this integrity is LLA collar torque resistance, which measures the strength of the Luer lock adaptor (LLA) collar under torque. This property ensures that the collar [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2105","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/da\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"LLA Collar Torque Resistance ISO 11040-4 Annex G4 In pharmaceutical manufacturing, ensuring the mechanical integrity of prefilled syringes is critical to product safety and performance. One key factor in this integrity is LLA collar torque resistance, which measures the strength of the Luer lock adaptor (LLA) collar under torque. This property ensures that the collar&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/posts\/2105","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/comments?post=2105"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/posts\/2105\/revisions"}],"predecessor-version":[{"id":2111,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/posts\/2105\/revisions\/2111"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/media?parent=2105"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/categories?post=2105"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/tags?post=2105"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}