{"id":2073,"date":"2025-04-22T03:59:40","date_gmt":"2025-04-22T03:59:40","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2073"},"modified":"2025-04-22T06:49:25","modified_gmt":"2025-04-22T06:49:25","slug":"luer-cone-breakage-resistance-iso-11040-4","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/da\/luer-cone-breakage-resistance-iso-11040-4\/","title":{"rendered":"Modstand mod brud p\u00e5 luerkonus - ISO 11040-4 Annex C2"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2073\" class=\"elementor elementor-2073\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ef785b6 e-flex e-con-boxed e-con e-parent\" data-id=\"ef785b6\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-6d4a251 elementor-widget elementor-widget-heading\" data-id=\"6d4a251\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Luer Cone Breakage Resistance<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b910e1 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"8b910e1\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec4bbc1 elementor-widget elementor-widget-heading\" data-id=\"ec4bbc1\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Bilag C2<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-bdc54b0 e-flex e-con-boxed e-con e-parent\" data-id=\"bdc54b0\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a300c79 elementor-widget elementor-widget-text-editor\" data-id=\"a300c79\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"400\" data-end=\"1016\">I spr\u00f8jteproduktion og kvalitetskontrol er en af de mest kritiske mekaniske vurderinger <strong data-start=\"520\" data-end=\"553\">modstandsdygtighed over for brud p\u00e5 luer-konus<\/strong> test. Den strukturelle integritet af spr\u00f8jtens forende, is\u00e6r luer-keglen, har direkte indflydelse p\u00e5 b\u00e5de patientsikkerheden og enhedens p\u00e5lidelighed. For at sikre en konsekvent, standardiseret evaluering er <em data-start=\"749\" data-end=\"762\">ISO 11040-4<\/em> standard-specifikt <em data-start=\"785\" data-end=\"795\">Bilag C2<\/em>-beskriver procedurerne og kravene til udf\u00f8relse af denne test. Denne artikel vil lede dig gennem testprocessen, vigtigt udstyr og datafortolkning, der er n\u00f8dvendig for at overholde <a href=\"https:\/\/www.pharmacopoeiatest.com\/da\/iso-11040-4\/\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> teststandarder.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b3c5bd5 elementor-widget elementor-widget-heading\" data-id=\"b3c5bd5\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Betydningen af Luer-keglens brudmodstand<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60ddf4e elementor-widget elementor-widget-text-editor\" data-id=\"60ddf4e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Luer-keglen, der sidder forrest p\u00e5 spr\u00f8jtens cylinder, er et potentielt svagt punkt, der er udsat for mekanisk belastning under h\u00e5ndtering, samling eller injektion. <strong data-start=\"1248\" data-end=\"1281\">Modstandsdygtighed over for brud p\u00e5 luer-konus<\/strong> Testen hj\u00e6lper med at bestemme, hvor meget kraft keglen kan modst\u00e5, f\u00f8r den kn\u00e6kker. For producenter af <em data-start=\"1384\" data-end=\"1405\">Forfyldte spr\u00f8jter<\/em> og <em data-start=\"1410\" data-end=\"1441\">Glast\u00f8nder til injektionsv\u00e6sker<\/em>er denne test ikke bare et lovkrav - det er en grundl\u00e6ggende kvalitetskontrolforanstaltning for at undg\u00e5 fejl i medicinske applikationer.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3d476dd elementor-widget elementor-widget-heading\" data-id=\"3d476dd\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Annex C2 Luer Cone Breakage Resistance Test Method<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-642e2e7 elementor-widget elementor-widget-text-editor\" data-id=\"642e2e7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1582\" data-end=\"2040\">Den <strong data-start=\"1636\" data-end=\"1651\">ISO 11040-4<\/strong> standard med titlen <em data-start=\"1669\" data-end=\"1784\">F\u00e6rdigfyldte spr\u00f8jter - Del 4: Glasbeholdere til injektionsv\u00e6sker og steriliserede, f\u00e6rdigsamlede spr\u00f8jter klar til fyldning<\/em>inkluderer <strong data-start=\"1795\" data-end=\"1807\">Bilag C2<\/strong>som beskriver <em data-start=\"1827\" data-end=\"1858\">Modstandsdygtighed over for brud p\u00e5 forenden<\/em> test. Dette afsnit beskriver de forhold, hvorunder testen skal udf\u00f8res, herunder krav til apparatur, pr\u00f8veh\u00e5ndtering, testprocedurer og resultatdokumentation.<\/p><h3 class=\"\" data-start=\"2042\" data-end=\"2077\">De vigtigste testbetingelser omfatter:<\/h3><ul><li data-start=\"2080\" data-end=\"2105\">Test hastighed: <strong data-start=\"2092\" data-end=\"2105\">25 mm\/min<\/strong><\/li><li data-start=\"2080\" data-end=\"2105\">Anvendelsessted: <strong style=\"font-size: 16px;\" data-start=\"2127\" data-end=\"2135\">2 mm<\/strong><span style=\"font-size: 16px;\"> fra spr\u00f8jtespidsen<\/span><\/li><li data-start=\"2080\" data-end=\"2105\">Minimum samplingshastighed: <strong style=\"font-size: 16px;\" data-start=\"2182\" data-end=\"2192\">500 Hz<\/strong><span style=\"font-size: 16px;\"> for maksimal m\u00e5len\u00f8jagtighed<\/span><\/li><li data-start=\"2080\" data-end=\"2105\">Anvendt kraft indtil <strong style=\"font-size: 16px;\" data-start=\"2245\" data-end=\"2263\">Glasbrud<\/strong><span style=\"font-size: 16px;\"> forekommer<\/span><\/li><\/ul><p class=\"\" data-start=\"2272\" data-end=\"2390\">Ved at f\u00f8lge denne vejledning sikrer du, at din <strong data-start=\"2314\" data-end=\"2333\">Spr\u00f8jtetestning<\/strong> processer forbliver sporbare, reproducerbare og kompatible.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4dbc7e2 elementor-widget elementor-widget-heading\" data-id=\"4dbc7e2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Spr\u00f8jtetester til ISO 11040-4 Annex C2-testning<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7da5e4d elementor-widget elementor-widget-text-editor\" data-id=\"7da5e4d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2454\" data-end=\"2671\">For at udf\u00f8re n\u00f8jagtigt <strong data-start=\"2476\" data-end=\"2509\">modstandsdygtighed over for brud p\u00e5 luer-konus<\/strong> test, skal du bruge en p\u00e5lidelig og pr\u00e6cis <strong data-start=\"2552\" data-end=\"2605\">Universal tr\u00e6k- og trykpr\u00f8vemaskine<\/strong>. Apparatet skal opfylde disse krav i ISO 11040-4 Annex C2:<\/p><ul><li data-start=\"2675\" data-end=\"2729\">A <strong data-start=\"2677\" data-end=\"2690\">Vejecelle<\/strong> velegnet til m\u00e5ling af brudkr\u00e6fter<\/li><li data-start=\"2675\" data-end=\"2729\">En pr\u00e6cis, programmerbar <strong style=\"font-size: 16px;\" data-start=\"2758\" data-end=\"2780\">kontrol af testhastighed<\/strong><\/li><li data-start=\"2675\" data-end=\"2729\">En skik <strong style=\"font-size: 16px;\" data-start=\"2792\" data-end=\"2834\">Holder og ladestang i rustfrit st\u00e5l<\/strong><\/li><li data-start=\"2675\" data-end=\"2729\">Adapters\u00e6t, der passer til din spr\u00f8jtes designgeometri<\/li><\/ul><h3 class=\"\" data-start=\"2889\" data-end=\"2967\">Anbefalet spr\u00f8jtetester<\/h3><p class=\"\" data-start=\"2969\" data-end=\"3383\">Cell Instruments' <em>Spr\u00f8jtetester<\/em>\u00a0er designet til at opfylde de strenge krav til ISO-spr\u00f8jtetestning. MPT-01 er udstyret med programmerbar PLC-kontrol, pr\u00e6cisionsmekanik og fiksturer, der kan tilpasses, og giver kraft- og forskydningsdata i h\u00f8j opl\u00f8sning, hvilket g\u00f8r den ideel til <strong data-start=\"3241\" data-end=\"3274\">modstandsdygtighed over for brud p\u00e5 luer-konus<\/strong> vurderinger. Den integrerede mikroprinter og valgfri RS232-dataeksport underst\u00f8tter ogs\u00e5 detaljeret dokumentation.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b4ff2b elementor-widget elementor-widget-heading\" data-id=\"6b4ff2b\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Testprocedure for modstandsdygtighed over for luer-keglebrud<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-c990a3c e-con-full e-flex e-con e-child\" data-id=\"c990a3c\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-dbcf8eb e-con-full e-flex e-con e-child\" data-id=\"dbcf8eb\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-53324d6 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"53324d6\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"488\" height=\"1024\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp\" class=\"attachment-large size-large wp-image-2048\" alt=\"ISO 11040-4 test af spr\u00f8jtel\u00e6kage\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp 488w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-143x300.webp 143w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-768x1613.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-731x1536.webp 731w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-975x2048.webp 975w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-scaled.webp 1219w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9962325 e-con-full e-flex e-con e-child\" data-id=\"9962325\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ea7609b elementor-widget elementor-widget-text-editor\" data-id=\"ea7609b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3460\" data-end=\"3483\"><strong>1. Forberedelse af test<\/strong><\/p><ul><li data-start=\"3486\" data-end=\"3553\">Unders\u00f8g alle adaptere og materialer for <strong data-start=\"3525\" data-end=\"3552\">skader eller kompatibilitet<\/strong>.<\/li><li data-start=\"3486\" data-end=\"3553\">Monter den n\u00f8dvendige adapter og armaturer p\u00e5 <strong style=\"font-size: 16px;\">Spr\u00f8jtetester<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3486\" data-end=\"3553\">S\u00f8rg for korrekt justering og <strong style=\"font-size: 16px;\" data-start=\"3652\" data-end=\"3677\">installere sikkerhedsafsk\u00e6rmninger<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><\/ul><p data-start=\"3680\" data-end=\"3704\"><strong>2. Udf\u00f8relse af test<\/strong><\/p><ul><li data-start=\"3707\" data-end=\"3749\">S\u00e6t spr\u00f8jtens cylinder ind i holderen.<\/li><li data-start=\"3707\" data-end=\"3749\">Placer indl\u00e6sningsstiften <strong style=\"font-size: 16px;\" data-start=\"3777\" data-end=\"3806\">2 mm fra spr\u00f8jtespidsen<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Indstil hastigheden til <strong style=\"font-size: 16px;\" data-start=\"3827\" data-end=\"3840\">25 mm\/min<\/strong><span style=\"font-size: 16px;\"> og start testen.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Anvend kompression, indtil luer-keglen <strong style=\"font-size: 16px;\" data-start=\"3901\" data-end=\"3914\">Frakturer<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3707\" data-end=\"3749\">Optag den <strong style=\"font-size: 16px;\" data-start=\"3929\" data-end=\"3958\">maksimal kraft ved brud<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4898eec elementor-widget__width-inherit elementor-widget elementor-widget-image\" data-id=\"4898eec\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"272\" height=\"270\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing.png\" class=\"attachment-large size-large wp-image-2078\" alt=\"Luer Cone Breakage Resistance - ISO 11040-4 Annex C2 Spr\u00f8jtetest\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing.png 272w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/Luer-Cone-Breakage-Resistance-ISO-11040-4-Annex-C2-Syringe-Testing-150x150.png 150w\" sizes=\"(max-width: 272px) 100vw, 272px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-322584f elementor-widget elementor-widget-text-editor\" data-id=\"322584f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p data-start=\"3961\" data-end=\"3999\"><b>3. Oprydning og analyse efter testen<\/b><\/p><ul><li data-start=\"4002\" data-end=\"4038\">Fjern forsigtigt den \u00f8delagte spr\u00f8jte.<\/li><li data-start=\"4002\" data-end=\"4038\">Reng\u00f8r adapteren for at fjerne eventuelle glasrester.<\/li><li data-start=\"4002\" data-end=\"4038\">Analyser resultater og bekr\u00e6ft <strong style=\"font-size: 16px;\" data-start=\"4117\" data-end=\"4138\">Frakturens placering<\/strong><span style=\"font-size: 16px;\"> i den forreste ende.<\/span><\/li><\/ul>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04ee823 elementor-widget elementor-widget-heading\" data-id=\"04ee823\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Krav til resultatrapportering i henhold til ISO 11040-4<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9a8c95c elementor-widget elementor-widget-text-editor\" data-id=\"9a8c95c\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4216\" data-end=\"4286\">Hver test skal dokumenteres grundigt, herunder f\u00f8lgende data:<\/p><ul><li data-start=\"4289\" data-end=\"4313\"><strong data-start=\"4289\" data-end=\"4303\">Test hastighed<\/strong> i mm\/min<\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4316\" data-end=\"4349\">Afstand fra spr\u00f8jtespidsen<\/strong><span style=\"font-size: 16px;\"> hvor kraften blev p\u00e5f\u00f8rt<\/span><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4383\" data-end=\"4409\">Maksimal brudkraft<\/strong><span style=\"font-size: 16px;\"> i newton (N)<\/span><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4427\" data-end=\"4446\">Antal pr\u00f8ver<\/strong><\/li><li data-start=\"4289\" data-end=\"4313\"><strong style=\"font-size: 16px;\" data-start=\"4449\" data-end=\"4480\">Eventuelle uregelm\u00e6ssigheder eller afvigelser<\/strong><span style=\"font-size: 16px;\"> fra proceduren<\/span><\/li><\/ul><p class=\"\" data-start=\"4501\" data-end=\"4652\">Denne detaljeringsgrad sikrer konsistens og muligg\u00f8r sporbarhed, is\u00e6r n\u00e5r man validerer nye spr\u00f8jtedesigns eller udf\u00f8rer rutinem\u00e6ssige kvalitetskontroller.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c3b5bb elementor-widget elementor-widget-heading\" data-id=\"5c3b5bb\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hvorfor v\u00e6lge Cell Instruments til spr\u00f8jtetest?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7471474 elementor-widget elementor-widget-text-editor\" data-id=\"7471474\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4659\" data-end=\"5243\">Med \u00e5rtiers erfaring inden for <strong data-start=\"4744\" data-end=\"4779\">Test af materialer til medicinsk udstyr<\/strong>, <strong data-start=\"4781\" data-end=\"4801\">Cell-instrumenter<\/strong> tilbyder topmoderne testl\u00f8sninger, der er skr\u00e6ddersyet til ISO- og ASTM-standarder. Vores <strong>Spr\u00f8jtetester<\/strong> er specielt udviklet til at underst\u00f8tte en r\u00e6kke forskellige <strong data-start=\"4971\" data-end=\"4990\">Spr\u00f8jtetestning<\/strong> metoder, herunder <strong data-start=\"5010\" data-end=\"5043\">modstandsdygtighed over for brud p\u00e5 luer-konus<\/strong>. Uanset om du er i produktion, forskning eller tredjepartsverifikation, kan Cell Instruments levere tilpassede l\u00f8sninger, automatiseringsintegration og omfattende support til at opfylde dine testbehov.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-02c15b6 elementor-widget elementor-widget-text-editor\" data-id=\"02c15b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"5250\" data-end=\"5668\">At optr\u00e6de <strong data-start=\"5278\" data-end=\"5311\">modstandsdygtighed over for brud p\u00e5 luer-konus<\/strong> test i overensstemmelse med <strong data-start=\"5337\" data-end=\"5361\"><a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a> Bilag C2<\/strong> er afg\u00f8rende for at sikre den mekaniske integritet af spr\u00f8jtens komponenter. Ved at bruge n\u00f8jagtigt udstyr som <strong>Spr\u00f8jtetester<\/strong>Hvis du f\u00f8lger den ISO-anbefalede procedure trin for trin, kan du med sikkerhed verificere produktkvaliteten, overholde lovgivningen og beskytte patientsikkerheden.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3344b6 elementor-widget elementor-widget-text-editor\" data-id=\"a3344b6\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"5420\" data-end=\"5503\"><strong data-start=\"5675\" data-end=\"5746\">Leder du efter spr\u00f8jtetestl\u00f8sninger, der overholder ISO 11040-4?<\/strong><\/p><p class=\"\" data-start=\"5420\" data-end=\"5503\">Kontakt <strong data-start=\"5757\" data-end=\"5787\">Cell Instruments Co., Ltd.<\/strong> i dag for at f\u00e5 ekspertvejledning og skr\u00e6ddersyede testsystemer til dine behov for kvalitetssikring af spr\u00f8jter.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Luer Cone Breakage Resistance ISO 11040-4 Annex C2 In syringe manufacturing and quality control, one of the most critical mechanical assessments is the luer cone breakage resistance test. The structural integrity of the syringe front end, especially the luer cone, directly impacts both patient safety and device reliability. To ensure consistent, standardized evaluation, the ISO [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"disabled","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2073","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/da\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Luer Cone Breakage Resistance ISO 11040-4 Annex C2 In syringe manufacturing and quality control, one of the most critical mechanical assessments is the luer cone breakage resistance test. The structural integrity of the syringe front end, especially the luer cone, directly impacts both patient safety and device reliability. To ensure consistent, standardized evaluation, the ISO&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/posts\/2073","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/comments?post=2073"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/posts\/2073\/revisions"}],"predecessor-version":[{"id":2084,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/posts\/2073\/revisions\/2084"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/media?parent=2073"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/categories?post=2073"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/da\/wp-json\/wp\/v2\/tags?post=2073"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}