{"id":2666,"date":"2026-08-19T01:11:00","date_gmt":"2026-08-19T01:11:00","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2666"},"modified":"2026-08-19T01:11:02","modified_gmt":"2026-08-19T01:11:02","slug":"glass-grain-sampler-for-hydrolytic-resistance","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/cs\/glass-grain-sampler-for-hydrolytic-resistance\/","title":{"rendered":"Sklen\u011bn\u00fd vzorkova\u010d zrn pro zkou\u0161en\u00ed odolnosti proti hydrol\u00fdze"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Na str\u00e1nk\u00e1ch <strong><a href=\"https:\/\/www.pharmacopoeiatest.com\/cs\/category\/product\/glass-grain-sampler\/\" target=\"_blank\" rel=\"noreferrer noopener\">Sklen\u011bn\u00fd vzorkova\u010d zrn pro stanoven\u00ed odolnosti proti hydrol\u00fdze<\/a><\/strong> je automatizovan\u00fd p\u0159\u00edstroj pro p\u0159\u00edpravu vzork\u016f ur\u010den\u00fd k hodnocen\u00ed farmaceutick\u00fdch sklen\u011bn\u00fdch obal\u016f. Zaji\u0161\u0165uje standardizovan\u00e9 procesy drcen\u00ed, pros\u00e9v\u00e1n\u00ed a sb\u011bru skla, kter\u00e9 jsou nezbytn\u00e9 pro <strong>Zkou\u0161ka hydrolytick\u00e9 odolnosti sklen\u011bn\u00fdch obal\u016f<\/strong> v souladu s mezin\u00e1rodn\u00edmi normami, jako jsou nap\u0159\u00edklad<a href=\"https:\/\/www.pharmacopoeiatest.com\/cs\/iso-719\/\"> <strong>ISO 71<\/strong><\/a><strong><a href=\"https:\/\/www.pharmacopoeiatest.com\/cs\/iso-719\/\" target=\"_blank\" rel=\"noreferrer noopener\">9<\/a><\/strong><a href=\"https:\/\/www.pharmacopoeiatest.com\/cs\/iso-719\/\"> <\/a>a <strong>ISO 720<\/strong>.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">P\u0159i kontrole kvality farmaceutick\u00fdch obal\u016f je p\u0159esn\u00e9 posouzen\u00ed chemick\u00e9 odolnosti skla z\u00e1sadn\u00ed, proto\u017ee sklen\u011bn\u00e9 n\u00e1doby p\u0159ich\u00e1zej\u00ed do p\u0159\u00edm\u00e9ho kontaktu s citliv\u00fdmi l\u00e9\u010div\u00fdmi p\u0159\u00edpravky. P\u0159ed proveden\u00edm zkou\u0161ky odolnosti proti hydrol\u00fdze je nutn\u00e9 vzorky skla p\u0159ipravit do po\u017eadovan\u00fdch velikost\u00ed zrn s kontrolovan\u00fdm rozlo\u017een\u00edm \u010d\u00e1stic. Za\u0159\u00edzen\u00ed Glass Grain Sampler pom\u00e1h\u00e1 laborato\u0159\u00edm zajistit konzistentn\u00ed p\u0159\u00edpravu vzork\u016f, omezit odchylky zp\u016fsoben\u00e9 obsluhou a zv\u00fd\u0161it spolehlivost testov\u00e1n\u00ed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">D\u00edky integraci funkc\u00ed mlet\u00ed a pros\u00e9v\u00e1n\u00ed do jednoho automatizovan\u00e9ho syst\u00e9mu p\u0159edstavuje toto za\u0159\u00edzen\u00ed efektivn\u00ed \u0159e\u0161en\u00ed pro v\u00fdrobce l\u00e9\u010div, dodavatele sklen\u011bn\u00fdch obal\u016f, regula\u010dn\u00ed laborato\u0159e a odd\u011blen\u00ed kontroly kvality, kter\u00e9 pot\u0159ebuj\u00ed spolehlivou p\u0159\u00edpravu sklen\u011bn\u00fdch zrn pro hodnocen\u00ed odolnosti proti hydrol\u00fdze.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pro\u010d je d\u016fle\u017eit\u00e9 testov\u00e1n\u00ed hydrolytick\u00e9 odolnosti sklen\u011bn\u00fdch obal\u016f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Farmaceutick\u00e9 sklen\u011bn\u00e9 obaly se d\u00edky sv\u00e9 vynikaj\u00edc\u00ed pr\u016fhlednosti, chemick\u00e9 stabilit\u011b a ochrann\u00fdm vlastnostem \u0161iroce pou\u017e\u00edvaj\u00ed pro injek\u010dn\u00ed l\u00e9\u010diva, infuzn\u00ed roztoky, peror\u00e1ln\u00ed tekut\u00e9 p\u0159\u00edpravky a dal\u0161\u00ed zdravotnick\u00e9 produkty. Sklo v\u0161ak nen\u00ed zcela inertn\u00ed. P\u0159i interakci sklen\u011bn\u00fdch povrch\u016f s vodou nebo vodn\u00fdmi farmaceutick\u00fdmi p\u0159\u00edpravky se mohou ur\u010dit\u00e9 alkalick\u00e9 slo\u017eky obsa\u017een\u00e9 ve struktu\u0159e skla rozpou\u0161t\u011bt do roztoku.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tento proces, zn\u00e1m\u00fd jako hydrolytick\u00e9 p\u016fsoben\u00ed, m\u016f\u017ee m\u00edt vliv na:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Stabilita l\u00e9kov\u00fdch p\u0159\u00edpravk\u016f<\/li>\n\n\n\n<li>Rovnov\u00e1ha pH roztoku<\/li>\n\n\n\n<li>Doba trvanlivosti v\u00fdrobku<\/li>\n\n\n\n<li>Bezpe\u010dnost pacient\u016f<\/li>\n\n\n\n<li>Dlouhodob\u00e1 kompatibilita kontejner\u016f<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u00da\u010delem zkou\u0161ky hydrolytick\u00e9 odolnosti je zjistit, jak \u00fa\u010dinn\u011b sklen\u011bn\u00e9 materi\u00e1ly odol\u00e1vaj\u00ed chemick\u00e9 interakci s vodou za kontrolovan\u00fdch podm\u00ednek.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Spolehliv\u00e9 testov\u00e1n\u00ed odolnosti proti hydrol\u00fdze pom\u00e1h\u00e1 v\u00fdrobc\u016fm:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">C\u00edl kontroly kvality<\/th><th class=\"has-text-align-center\" data-align=\"center\">V\u00fdhoda<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Posoudit chemickou odolnost skla<\/td><td class=\"has-text-align-center\" data-align=\"center\">Zajist\u011bte, aby kontejnery zachovaly sv\u016fj v\u00fdkon b\u011bhem skladov\u00e1n\u00ed<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">\u0158\u00edzen\u00ed uvol\u0148ov\u00e1n\u00ed iont\u016f ze skla<\/td><td class=\"has-text-align-center\" data-align=\"center\">Sn\u00ed\u017eit potenci\u00e1ln\u00ed dopad na slo\u017een\u00ed l\u00e9\u010div\u00fdch p\u0159\u00edpravk\u016f<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Ov\u011b\u0159te kompatibilitu obal\u016f<\/td><td class=\"has-text-align-center\" data-align=\"center\">Podpora bezpe\u010dn\u00e9ho v\u00fdvoje farmaceutick\u00fdch p\u0159\u00edpravk\u016f<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Splnit regula\u010dn\u00ed po\u017eadavky<\/td><td class=\"has-text-align-center\" data-align=\"center\">Dodr\u017eovat normy mezin\u00e1rodn\u00edch l\u00e9kopis\u016f<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Zlep\u0161it konzistenci v\u00fdroby<\/td><td class=\"has-text-align-center\" data-align=\"center\">Zajistit st\u00e1lou kvalitu nap\u0159\u00ed\u010d jednotliv\u00fdmi \u0161ar\u017eemi<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Pro v\u00fdrobce farmaceutick\u00fdch obal\u016f nen\u00ed hodnocen\u00ed hydrolytick\u00e9 odolnosti pouze regula\u010dn\u00edm po\u017eadavkem, ale tak\u00e9 d\u016fle\u017eitou sou\u010d\u00e1st\u00ed zaji\u0161t\u011bn\u00ed bezpe\u010dnosti l\u00e9\u010div.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Co je to sklen\u011bn\u00fd vzorkova\u010d zrn pro stanoven\u00ed odolnosti proti hydrol\u00fdze?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A <strong>Sklen\u011bn\u00fd vzorkova\u010d zrn pro stanoven\u00ed odolnosti proti hydrol\u00fdze<\/strong> je specializovan\u00fd laboratorn\u00ed p\u0159\u00edstroj, kter\u00fd se pou\u017e\u00edv\u00e1 k p\u0159\u00edprav\u011b vzork\u016f sklen\u011bn\u00fdch zrn p\u0159ed zkou\u0161kou hydrolytick\u00e9 odolnosti.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Tento p\u0159\u00edstroj p\u0159em\u011b\u0148uje farmaceutick\u00e9 sklen\u011bn\u00e9 n\u00e1doby na standardizovan\u00e9 sklen\u011bn\u00e9 \u010d\u00e1stice pomoc\u00ed \u0159\u00edzen\u00e9ho mechanick\u00e9ho drcen\u00ed a p\u0159esn\u00e9ho pros\u00e9v\u00e1n\u00ed. Takto p\u0159ipraven\u00e1 sklen\u011bn\u00e1 zrna se pot\u00e9 pou\u017e\u00edvaj\u00ed pro r\u016fzn\u00e9 vyhodnocovac\u00ed metody, jako jsou nap\u0159\u00edklad:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Odolnost sklen\u011bn\u00fdch zrn proti hydrol\u00fdze p\u0159i teplot\u011b 98 \u00b0C<\/strong> podle normy ISO 719<\/li>\n\n\n\n<li><strong>Odolnost sklen\u011bn\u00fdch zrn proti hydrol\u00fdze p\u0159i teplot\u011b 121 \u00b0C<\/strong> podle normy ISO 720<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Tradi\u010dn\u00ed ru\u010dn\u00ed zp\u016fsoby p\u0159\u00edpravy mohou zahrnovat samostatn\u00e9 operace drcen\u00ed a pros\u00e9v\u00e1n\u00ed, co\u017e m\u016f\u017ee v\u00e9st k odchylk\u00e1m zp\u016fsoben\u00fdm zp\u016fsobem manipulace obsluhy, kol\u00eds\u00e1n\u00edm s\u00edly drcen\u00ed nebo kontaminac\u00ed \u010d\u00e1sticemi.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Automatick\u00fd vzorkova\u010d sklen\u011bn\u00fdch zrn zefektiv\u0148uje proces p\u0159\u00edpravy t\u00edm, \u017ee nab\u00edz\u00ed:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u0158\u00edzen\u00e9 podm\u00ednky drcen\u00ed<\/li>\n\n\n\n<li>Opakovateln\u00e9 rozlo\u017een\u00ed velikosti \u010d\u00e1stic<\/li>\n\n\n\n<li>Sn\u00ed\u017een\u00fd vliv obsluhy<\/li>\n\n\n\n<li>Zv\u00fd\u0161en\u00ed efektivity laborato\u0159e<\/li>\n\n\n\n<li>Bezpe\u010dn\u011bj\u0161\u00ed manipulace s rozbit\u00fdm sklem<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Pro laborato\u0159e, kter\u00e9 prov\u00e1d\u011bj\u00ed \u010dast\u00e9 zkou\u0161ky farmaceutick\u00e9ho skla, p\u0159isp\u00edv\u00e1 automatizovan\u00e1 p\u0159\u00edprava vzork\u016f k z\u00edsk\u00e1n\u00ed spolehliv\u011bj\u0161\u00edch a srovnateln\u011bj\u0161\u00edch v\u00fdsledk\u016f zkou\u0161ek.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Z\u00e1sady p\u0159\u00edpravy sklen\u011bn\u00fdch zrn pro zkou\u0161ky odolnosti proti hydrol\u00fdze<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Princip p\u0159\u00edpravy spo\u010d\u00edv\u00e1 v mechanick\u00e9m drcen\u00ed a n\u00e1sledn\u00e9m t\u0159\u00edd\u011bn\u00ed podle velikosti \u010d\u00e1stic.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Sklen\u011bn\u00fd vzorek se nejprve vlo\u017e\u00ed do integrovan\u00e9ho t\u0159ec\u00edho n\u00e1dob\u00ed. Automatick\u00e9 tlou\u010d\u00edtko p\u016fsob\u00ed \u0159\u00edzenou silou, aby sklo rozdrtilo na men\u0161\u00ed \u010d\u00e1stice. Po rozdrcen\u00ed syst\u00e9m vibra\u010dn\u00edho pros\u00e9v\u00e1n\u00ed rozt\u0159\u00edd\u00ed sklen\u011bn\u00e1 zrna podle stanoven\u00fdch po\u017eadavk\u016f na velikost \u010d\u00e1stic.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cel\u00fd proces p\u0159\u00edpravy zahrnuje:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Krok procesu<\/th><th class=\"has-text-align-center\" data-align=\"center\">Popis<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Vkl\u00e1d\u00e1n\u00ed vzork\u016f<\/td><td class=\"has-text-align-center\" data-align=\"center\">Vlo\u017ete sklen\u011bn\u00fd materi\u00e1l do standardn\u00edho hmo\u017ed\u00ed\u0159e<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Drcen\u00ed<\/td><td class=\"has-text-align-center\" data-align=\"center\">Automatick\u00fd tlouk rozdrt\u00ed sklo na men\u0161\u00ed kousky<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Pros\u00e9v\u00e1n\u00ed<\/td><td class=\"has-text-align-center\" data-align=\"center\">Vibra\u010dn\u00ed s\u00edta t\u0159\u00edd\u00ed \u010d\u00e1stice podle velikosti<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Kolekce<\/td><td class=\"has-text-align-center\" data-align=\"center\">K testov\u00e1n\u00ed se shroma\u017e\u010fuj\u00ed vybran\u00e1 sklen\u011bn\u00e1 zrna<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Hodnocen\u00ed hydrolytick\u00e9 odolnosti<\/td><td class=\"has-text-align-center\" data-align=\"center\">K testov\u00e1n\u00ed chemick\u00e9 odolnosti se pou\u017e\u00edvaj\u00ed p\u0159ipraven\u00e9 vzorky<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">D\u016fle\u017eit\u00e9 je jednotn\u00e9 zpracov\u00e1n\u00ed zrn, proto\u017ee rozlo\u017een\u00ed velikosti \u010d\u00e1stic ovliv\u0148uje kontaktn\u00ed plochu mezi sklen\u011bn\u00fdmi zrny a vodou b\u011bhem testov\u00e1n\u00ed. Standardizovan\u00e9 zpracov\u00e1n\u00ed zaji\u0161\u0165uje, \u017ee r\u016fzn\u00e9 laborato\u0159e mohou dos\u00e1hnout srovnateln\u00fdch v\u00fdsledk\u016f.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Jak se prov\u00e1d\u00ed zkou\u0161ka hydrolytick\u00e9 odolnosti sklen\u011bn\u00fdch obal\u016f?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Na str\u00e1nk\u00e1ch <strong>Zkou\u0161ka hydrolytick\u00e9 odolnosti sklen\u011bn\u00fdch obal\u016f<\/strong> Obvykle zahrnuje p\u0159\u00edpravu sklen\u011bn\u00fdch vzork\u016f a jejich vystaven\u00ed kontrolovan\u00fdm vodn\u00edm podm\u00ednk\u00e1m.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">P\u0159i zkou\u0161k\u00e1ch skla metodou zrnitosti je rozhoduj\u00edc\u00ed f\u00e1ze p\u0159\u00edpravy:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Vyberte reprezentativn\u00ed vzorky sklen\u011bn\u00fdch n\u00e1dob.<\/li>\n\n\n\n<li>Sklo rozdr\u0165te na zrnka pomoc\u00ed standardn\u00ed p\u0159\u00edpravn\u00e9 metody.<\/li>\n\n\n\n<li>Odd\u011blte vhodn\u00e9 \u010d\u00e1stice pros\u00e9v\u00e1n\u00edm.<\/li>\n\n\n\n<li>Sklen\u011bn\u00e1 zrna o\u010dist\u011bte a p\u0159ipravte v souladu s po\u017eadavky na zkou\u0161en\u00ed.<\/li>\n\n\n\n<li>Prove\u010fte hodnocen\u00ed hydrolytick\u00e9 odolnosti za stanoven\u00fdch teplotn\u00edch podm\u00ednek.<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">R\u016fzn\u00e9 normy stanovuj\u00ed r\u016fzn\u00e9 zku\u0161ebn\u00ed teploty:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Zku\u0161ebn\u00ed metoda<\/th><th class=\"has-text-align-center\" data-align=\"center\">Teplotn\u00ed podm\u00ednky<\/th><th class=\"has-text-align-center\" data-align=\"center\">\u00da\u010del<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.iso.org\/standard\/77843.html\" target=\"_blank\" rel=\"noreferrer noopener\">ISO 719<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\">98 \u00b0C<\/td><td class=\"has-text-align-center\" data-align=\"center\">Vyhodnotit hydrolytickou odolnost sklen\u011bn\u00fdch zrn za standardn\u00edch podm\u00ednek<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.iso.org\/standard\/77844.html\" target=\"_blank\" rel=\"noreferrer noopener\">ISO 720<\/a><\/td><td class=\"has-text-align-center\" data-align=\"center\">121 \u00b0C<\/td><td class=\"has-text-align-center\" data-align=\"center\">Vyhodnotit odolnost proti hydrol\u00fdze p\u0159i vy\u0161\u0161\u00edch teplot\u00e1ch<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Za\u0159\u00edzen\u00ed Glass Grain Sampler usnad\u0148uje p\u0159\u00edpravu vzork\u016f p\u0159ed t\u011bmito zkou\u0161kami, \u010d\u00edm\u017e pom\u00e1h\u00e1 laborato\u0159\u00edm zv\u00fd\u0161it opakovatelnost v\u00fdsledk\u016f a omezit chyby vznikaj\u00edc\u00ed p\u0159i ru\u010dn\u00ed p\u0159\u00edprav\u011b.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Ru\u010dn\u00ed p\u0159\u00edprava vs. automatizovan\u00e1 p\u0159\u00edprava sklen\u011bn\u00fdch zrn<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Automatizovan\u00e1 p\u0159\u00edprava nab\u00edz\u00ed v\u00fdhody oproti tradi\u010dn\u00edm ru\u010dn\u00edm metod\u00e1m mlet\u00ed a pros\u00e9v\u00e1n\u00ed.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Srovn\u00e1vac\u00ed polo\u017eka<\/th><th class=\"has-text-align-center\" data-align=\"center\">P\u0159\u00edprava podle n\u00e1vodu<\/th><th class=\"has-text-align-center\" data-align=\"center\">Automatick\u00fd vzorkova\u010d sklen\u011bn\u00fdch zrn<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Proces drcen\u00ed<\/td><td class=\"has-text-align-center\" data-align=\"center\">Z\u00e1le\u017e\u00ed na technice oper\u00e1tora<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u0158\u00edzen\u00fd automatick\u00fd provoz<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Konzistence \u010d\u00e1stic<\/td><td class=\"has-text-align-center\" data-align=\"center\">M\u016f\u017ee se li\u0161it v z\u00e1vislosti na oper\u00e1torovi<\/td><td class=\"has-text-align-center\" data-align=\"center\">Stabiln\u00ed rozlo\u017een\u00ed velikosti zrn<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Pot\u0159eba pracovn\u00ed s\u00edly<\/td><td class=\"has-text-align-center\" data-align=\"center\">Vy\u017eaduje n\u011bkolik p\u0159\u00edpravn\u00fdch krok\u016f<\/td><td class=\"has-text-align-center\" data-align=\"center\">Integrovan\u00e9 drcen\u00ed a pros\u00e9v\u00e1n\u00ed<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Bezpe\u010dnost<\/td><td class=\"has-text-align-center\" data-align=\"center\">Vy\u0161\u0161\u00ed vystaven\u00ed sklen\u011bn\u00fdm st\u0159ep\u016fm<\/td><td class=\"has-text-align-center\" data-align=\"center\">Omezen\u00fd kontakt s obsluhou<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Opakovatelnost<\/td><td class=\"has-text-align-center\" data-align=\"center\">V\u011bt\u0161\u00ed vliv lidsk\u00fdch faktor\u016f<\/td><td class=\"has-text-align-center\" data-align=\"center\">Vy\u0161\u0161\u00ed konzistentnost testov\u00e1n\u00ed<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">V laborato\u0159\u00edch pro kontrolu kvality l\u00e9\u010div vede zlep\u0161en\u00ed konzistence p\u0159\u00edpravy vzork\u016f p\u0159\u00edmo ke spolehliv\u011bj\u0161\u00edm v\u00fdsledk\u016fm zkou\u0161ek hydrolytick\u00e9 odolnosti.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Vyu\u017eit\u00ed vzorkova\u010de sklen\u011bn\u00fdch zrn u farmaceutick\u00fdch sklen\u011bn\u00fdch obal\u016f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Vzorkova\u010d sklen\u011bn\u00fdch \u010d\u00e1stic je vhodn\u00fd pro p\u0159\u00edpravu vzork\u016f z r\u016fzn\u00fdch farmaceutick\u00fdch sklen\u011bn\u00fdch obalov\u00fdch materi\u00e1l\u016f.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Materi\u00e1l \/ V\u00fdrobek<\/th><th class=\"has-text-align-center\" data-align=\"center\">\u017d\u00e1dost<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Injek\u010dn\u00ed lahvi\u010dky<\/td><td class=\"has-text-align-center\" data-align=\"center\">Hodnocen\u00ed obal\u016f injek\u010dn\u00edch l\u00e9\u010div<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Ampulky<\/td><td class=\"has-text-align-center\" data-align=\"center\">Kontrola kvality l\u00e9ka\u0159sk\u00fdch sklen\u011bn\u00fdch obal\u016f<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Infuzn\u00ed l\u00e1hve<\/td><td class=\"has-text-align-center\" data-align=\"center\">Testov\u00e1n\u00ed velkoobjemov\u00fdch farmaceutick\u00fdch obal\u016f<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Lahvi\u010dky s tekut\u00fdm p\u0159\u00edpravkem pro peror\u00e1ln\u00ed pod\u00e1n\u00ed<\/td><td class=\"has-text-align-center\" data-align=\"center\">Hodnocen\u00ed chemick\u00e9 odolnosti<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Ostatn\u00ed farmaceutick\u00e9 sklen\u011bn\u00e9 obaly<\/td><td class=\"has-text-align-center\" data-align=\"center\">V\u00fdzkum a testov\u00e1n\u00ed pro regula\u010dn\u00ed \u00fa\u010dely<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Mezi typick\u00e9 u\u017eivatele pat\u0159\u00ed:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>V\u00fdrobci l\u00e9\u010div<\/li>\n\n\n\n<li>V\u00fdrobci sklen\u011bn\u00fdch obal\u016f<\/li>\n\n\n\n<li>Nez\u00e1visl\u00e9 zku\u0161ebn\u00ed laborato\u0159e<\/li>\n\n\n\n<li>Organizace zab\u00fdvaj\u00edc\u00ed se kontrolou kvality<\/li>\n\n\n\n<li>V\u00fdzkumn\u00e9 instituce<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Hlavn\u00ed vlastnosti a v\u00fdhody<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Za\u0159\u00edzen\u00ed Glass Grain Sampler kombinuje automatizovan\u00fd provoz s technologi\u00ed p\u0159\u00edpravy vzork\u016f spl\u0148uj\u00edc\u00ed p\u0159\u00edslu\u0161n\u00e9 normy.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Funkce<\/th><th class=\"has-text-align-center\" data-align=\"center\">V\u00fdhoda<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Hmo\u017ed\u00ed\u0159 a tlou\u010dek v souladu s normou<\/td><td class=\"has-text-align-center\" data-align=\"center\">Zaji\u0161\u0165uje st\u00e1l\u00e9 podm\u00ednky p\u0159i drcen\u00ed skla<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Integrovan\u00e9 drcen\u00ed a pros\u00e9v\u00e1n\u00ed<\/td><td class=\"has-text-align-center\" data-align=\"center\">Zjednodu\u0161uje pracovn\u00ed postupy a zvy\u0161uje efektivitu<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Automatizovan\u00fd provoz<\/td><td class=\"has-text-align-center\" data-align=\"center\">Sni\u017euje vliv obsluhy<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Ovl\u00e1d\u00e1n\u00ed pomoc\u00ed dotykov\u00e9 obrazovky HMI<\/td><td class=\"has-text-align-center\" data-align=\"center\">Zaji\u0161\u0165uje pohodln\u00e9 ovl\u00e1d\u00e1n\u00ed a nastaven\u00ed parametr\u016f<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">P\u0159esn\u00e9 vibra\u010dn\u00ed pros\u00e9v\u00e1n\u00ed<\/td><td class=\"has-text-align-center\" data-align=\"center\">Zaji\u0161\u0165uje p\u0159esn\u00e9 t\u0159\u00edd\u011bn\u00ed podle velikosti \u010d\u00e1stic<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Konstrukce bezpe\u010dnostn\u00edch ochrann\u00fdch prvk\u016f<\/td><td class=\"has-text-align-center\" data-align=\"center\">Sni\u017euje riziko p\u0159i zpracov\u00e1n\u00ed sklen\u011bn\u00fdch vzork\u016f<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Vysok\u00e1 opakovatelnost<\/td><td class=\"has-text-align-center\" data-align=\"center\">Spl\u0148uje po\u017eadavky na kvalitu v farmaceutick\u00e9m pr\u016fmyslu<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Technick\u00e9 specifikace<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th class=\"has-text-align-center\" data-align=\"center\">Parametr<\/th><th class=\"has-text-align-center\" data-align=\"center\">Specifikace<\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\">Rozm\u011bry hmo\u017ed\u00ed\u0159e a tlouku<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u03a650 \/ \u03a648 mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Otvor s\u00edta A<\/td><td class=\"has-text-align-center\" data-align=\"center\">425 \u03bcm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Otvor s\u00edta B<\/td><td class=\"has-text-align-center\" data-align=\"center\">300 \u03bcm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">S\u00edto O Otvor<\/td><td class=\"has-text-align-center\" data-align=\"center\">600 \u03bcm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Doba t\u0159ep\u00e1n\u00ed s\u00edta<\/td><td class=\"has-text-align-center\" data-align=\"center\">5 minut<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Tlak plynu<\/td><td class=\"has-text-align-center\" data-align=\"center\">0,5 MPa<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Velikost p\u0159\u00edvodu plynu<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u03a66 mm<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Nap\u00e1jec\u00ed zdroj<\/td><td class=\"has-text-align-center\" data-align=\"center\">110\u2013220 V st\u0159\u00eddav\u00e9ho proudu, 50\/60 Hz<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Pro\u010d pou\u017e\u00edvat automatizovan\u00e1 za\u0159\u00edzen\u00ed pro p\u0159\u00edpravu vzork\u016f skla pro zkou\u0161ku odolnosti proti hydrol\u00fdze?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Spolehliv\u00e9 testov\u00e1n\u00ed za\u010d\u00edn\u00e1 spolehlivou p\u0159\u00edpravou vzork\u016f. I kdy\u017e laborato\u0159e pou\u017e\u00edvaj\u00ed pokro\u010dil\u00e9 analytick\u00e9 metody, m\u016f\u017ee nespr\u00e1vn\u00e1 p\u0159\u00edprava sklen\u011bn\u00fdch zrn ovlivnit opakovatelnost test\u016f.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Automatick\u00fd vzorkova\u010d sklen\u011bn\u00fdch zrn p\u0159in\u00e1\u0161\u00ed v modern\u00edch prost\u0159ed\u00edch kontroly kvality n\u00e1sleduj\u00edc\u00ed v\u00fdhody:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Zvy\u0161ov\u00e1n\u00ed produktivity laborato\u0159\u00ed<\/li>\n\n\n\n<li>Podpora standardizovan\u00fdch postup\u016f p\u0159\u00edpravy<\/li>\n\n\n\n<li>Sni\u017eov\u00e1n\u00ed rozd\u00edl\u016f v ru\u010dn\u00edm ovl\u00e1d\u00e1n\u00ed<\/li>\n\n\n\n<li>Zv\u00fd\u0161en\u00ed bezpe\u010dnosti obsluhy<\/li>\n\n\n\n<li>Pom\u00e1h\u00e1me splnit po\u017eadavky na farmaceutick\u00e9 testov\u00e1n\u00ed<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Pro spole\u010dnosti zab\u00fdvaj\u00edc\u00ed se v\u00fdrobou farmaceutick\u00fdch sklen\u011bn\u00fdch obal\u016f nebo l\u00e9\u010div\u00fdch p\u0159\u00edpravk\u016f p\u0159edstavuje investice do spolehliv\u00e9ho p\u0159\u00edpravn\u00e9ho za\u0159\u00edzen\u00ed podporu pro lep\u0161\u00ed \u0159\u00edzen\u00ed kvality a dodr\u017eov\u00e1n\u00ed p\u0159edpis\u016f.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Spole\u010dnost Cell Instruments nab\u00edz\u00ed profesion\u00e1ln\u00ed \u0159e\u0161en\u00ed pro zkou\u0161en\u00ed materi\u00e1l\u016f ur\u010den\u00fdch pro farmaceutick\u00e9 obaly, zdravotnick\u00e9 materi\u00e1ly a pr\u016fmyslov\u00e9 aplikace v oblasti kontroly kvality. Pro speci\u00e1ln\u00ed laboratorn\u00ed pot\u0159eby jsou k dispozici tak\u00e9 up\u00ednac\u00ed p\u0159\u00edpravky a zku\u0161ebn\u00ed syst\u00e9my vyroben\u00e9 na m\u00edru.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Z\u00e1v\u011br<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Vzorkova\u010d sklen\u011bn\u00fdch zrn pro stanoven\u00ed hydrolytick\u00e9 odolnosti je automatizovan\u00fd laboratorn\u00ed p\u0159\u00edstroj ur\u010den\u00fd k p\u0159\u00edprav\u011b standardizovan\u00fdch vzork\u016f sklen\u011bn\u00fdch zrn pro testov\u00e1n\u00ed farmaceutick\u00fdch sklen\u011bn\u00fdch obal\u016f. D\u00edky integraci funkc\u00ed drcen\u00ed, pros\u00e9v\u00e1n\u00ed a sb\u011bru zaji\u0161\u0165uje tento syst\u00e9m konzistentn\u00ed p\u0159\u00edpravu vzork\u016f pro hodnocen\u00ed odolnosti proti hydrol\u00fdze v souladu s po\u017eadavky norem ISO 719 a ISO 720. Pom\u00e1h\u00e1 farmaceutick\u00fdm v\u00fdrobc\u016fm, dodavatel\u016fm sklen\u011bn\u00fdch obal\u016f a laborato\u0159\u00edm kontroly kvality zlep\u0161it efektivitu testov\u00e1n\u00ed, opakovatelnost v\u00fdsledk\u016f a dodr\u017eov\u00e1n\u00ed p\u0159edpis\u016f p\u0159i hodnocen\u00ed chemick\u00e9 odolnosti sklen\u011bn\u00fdch obalov\u00fdch materi\u00e1l\u016f pro l\u00e9ka\u0159sk\u00e9 \u00fa\u010dely.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">P\u0159esn\u00e9 testov\u00e1n\u00ed hydrolytick\u00e9 odolnosti z\u00e1vis\u00ed na spolehliv\u00e9 p\u0159\u00edprav\u011b sklen\u011bn\u00fdch vzork\u016f. Za\u0159\u00edzen\u00ed Glass Grain Sampler nab\u00edz\u00ed farmaceutick\u00fdm laborato\u0159\u00edm efektivn\u00ed \u0159e\u0161en\u00ed pro v\u00fdrobu standardizovan\u00fdch sklen\u011bn\u00fdch zrn pot\u0159ebn\u00fdch pro zku\u0161ebn\u00ed metody podle norem ISO a l\u00e9kopis\u016f. Spole\u010dnost Cell Instruments se specializuje na za\u0159\u00edzen\u00ed pro zkou\u0161en\u00ed materi\u00e1l\u016f a na \u0159e\u0161en\u00ed na m\u00edru pro farmaceutick\u00e9 obaly, zdravotnick\u00e9 v\u00fdrobky a pr\u016fmyslov\u00e9 aplikace. Kontaktujte n\u00e1\u0161 technick\u00fd t\u00fdm a zjist\u011bte, jak m\u016f\u017ee automatizovan\u00e9 za\u0159\u00edzen\u00ed na p\u0159\u00edpravu sklen\u011bn\u00fdch zrn zlep\u0161it pracovn\u00ed postupy ve va\u0161\u00ed laborato\u0159i a zv\u00fd\u0161it spolehlivost testov\u00e1n\u00ed.<\/p>","protected":false},"excerpt":{"rendered":"<p>Za\u0159\u00edzen\u00ed Glass Grain Sampler for Hydrolytic Resistance je automatizovan\u00fd p\u0159\u00edstroj pro p\u0159\u00edpravu vzork\u016f ur\u010den\u00fd k hodnocen\u00ed farmaceutick\u00fdch sklen\u011bn\u00fdch obal\u016f. Zaji\u0161\u0165uje standardizovan\u00e9 procesy drcen\u00ed, pros\u00e9v\u00e1n\u00ed a sb\u011bru skla, kter\u00e9 jsou nezbytn\u00e9 pro zkou\u0161ku hydrolytick\u00e9 odolnosti sklen\u011bn\u00fdch obal\u016f podle mezin\u00e1rodn\u00edch norem, jako jsou ISO 719 a ISO 720. P\u0159i kontrole kvality farmaceutick\u00fdch obal\u016f je p\u0159esn\u00e9 hodnocen\u00ed [\u2026]<\/p>","protected":false},"author":5,"featured_media":2668,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2666","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/08\/Glass-Grain-Sampler-for-Hydrolytic-Resistance-Testing.webp",600,600,false],"thumbnail":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/08\/Glass-Grain-Sampler-for-Hydrolytic-Resistance-Testing-150x150.webp",150,150,true],"medium":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/08\/Glass-Grain-Sampler-for-Hydrolytic-Resistance-Testing-300x300.webp",300,300,true],"medium_large":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/08\/Glass-Grain-Sampler-for-Hydrolytic-Resistance-Testing.webp",600,600,false],"large":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/08\/Glass-Grain-Sampler-for-Hydrolytic-Resistance-Testing.webp",600,600,false],"1536x1536":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/08\/Glass-Grain-Sampler-for-Hydrolytic-Resistance-Testing.webp",600,600,false],"2048x2048":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/08\/Glass-Grain-Sampler-for-Hydrolytic-Resistance-Testing.webp",600,600,false],"trp-custom-language-flag":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2026\/08\/Glass-Grain-Sampler-for-Hydrolytic-Resistance-Testing-12x12.webp",12,12,true]},"uagb_author_info":{"display_name":"Editor","author_link":"https:\/\/www.pharmacopoeiatest.com\/cs\/author\/editor\/"},"uagb_comment_info":0,"uagb_excerpt":"The Glass Grain Sampler for Hydrolytic Resistance is an automated sample preparation instrument designed for pharmaceutical glass container evaluation. It provides standardized glass crushing, sieving, and collection processes required for the Hydrolytic Resistance Test of Glass Containers according to international standards such as ISO 719 and ISO 720. In pharmaceutical packaging quality control, accurate evaluation&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/posts\/2666","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/comments?post=2666"}],"version-history":[{"count":1,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/posts\/2666\/revisions"}],"predecessor-version":[{"id":2667,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/posts\/2666\/revisions\/2667"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/media\/2668"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/media?parent=2666"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/categories?post=2666"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/tags?post=2666"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}