{"id":2267,"date":"2025-07-21T07:08:11","date_gmt":"2025-07-21T07:08:11","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2267"},"modified":"2025-07-21T07:21:09","modified_gmt":"2025-07-21T07:21:09","slug":"ampoule-mechanical-strength-tester","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/cs\/ampoule-mechanical-strength-tester\/","title":{"rendered":"Tester mechanick\u00e9 pevnosti ampul\u00ed podle ISO 9187"},"content":{"rendered":"<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-fccd8bb\" id=\"introduction\" data-block-id=\"fccd8bb\"><h2 class=\"stk-block-heading__text\">\u00davod<\/h2><\/div>\n\n\n\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-6c531013 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-uagb-container uagb-block-61ff3f36 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/cs\/category\/product\/ampoule-break-test\/\"><img fetchpriority=\"high\" decoding=\"async\" width=\"600\" height=\"600\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp\" alt=\"ampulov\u00fd tester mechanick\u00e9 pevnosti\" class=\"wp-image-2280\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp 600w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-300x300.webp 300w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-150x150.webp 150w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/a><figcaption class=\"wp-element-caption\">BST-01 Tester pro poru\u0161en\u00ed ampul\u00ed <\/figcaption><\/figure>\n<\/div><\/div>\n\n\n\n<p>P\u0159esn\u00e9 vyhodnocen\u00ed <strong>ampulov\u00fd tester mechanick\u00e9 pevnosti <\/strong>m\u00e1 z\u00e1sadn\u00ed v\u00fdznam pro kontrolu farmaceutick\u00e9 kvality. Sklen\u011bn\u00e9 ampule pou\u017e\u00edvan\u00e9 pro injek\u010dn\u00ed roztoky mus\u00ed b\u00fdt dostate\u010dn\u011b pevn\u00e9, aby si zachovaly sterilitu b\u011bhem p\u0159epravy a skladov\u00e1n\u00ed, a z\u00e1rove\u0148 mus\u00ed b\u00fdt dostate\u010dn\u011b snadn\u00e9 je otev\u0159\u00edt bez pou\u017eit\u00ed nadm\u011brn\u00e9 s\u00edly. Norma ISO 9187 stanov\u00ed standardizovan\u00e9 zku\u0161ebn\u00ed postupy pro hodnocen\u00ed t\u011bchto vlastnost\u00ed, zejm\u00e9na <strong>m\u011b\u0159en\u00ed s\u00edly p\u0159i rozb\u00edjen\u00ed sklen\u011bn\u00fdch ampul\u00ed<\/strong>. Tento \u010dl\u00e1nek v\u00e1s provede kompletn\u00edm postupem testov\u00e1n\u00ed pomoc\u00ed <strong><a href=\"https:\/\/www.pharmacopoeiatest.com\/cs\/category\/product\/ampoule-break-test\/\">BST-01 <strong>Tester mechanick\u00e9 pevnosti ampul\u00ed<\/strong><\/a><\/strong> od spole\u010dnosti Cell Instruments, \u010d\u00edm\u017e je zaji\u0161t\u011bna shoda s p\u0159edpisy a bezpe\u010dnost v\u00fdrobk\u016f.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-2c9d7c5\" id=\"breaking-force-measurement-for-glass-ampoules-using-bst-01-ampoule-tester\" data-block-id=\"2c9d7c5\"><h2 class=\"stk-block-heading__text\">M\u011b\u0159en\u00ed s\u00edly p\u0159i rozbit\u00ed sklen\u011bn\u00fdch ampul\u00ed pomoc\u00ed ampulometru BST-01<\/h2><\/div>\n\n\n\n<p><strong>Zlomov\u00e1 s\u00edla<\/strong> je kl\u00ed\u010dov\u00fdm parametrem mechanick\u00e9 integrity ampul\u00ed. Normy ISO 9187-1:2010 a ISO 9187-2 definuj\u00ed p\u0159\u00edsn\u00e1 krit\u00e9ria pro m\u011b\u0159en\u00ed t\u00e9to s\u00edly na z\u00fa\u017een\u00ed ampule, kter\u00e9 je obvykle ozna\u010deno keramick\u00fdm krou\u017ekem nebo barevn\u00fdm pigmentem.<\/p>\n\n\n\n<p>Na str\u00e1nk\u00e1ch <strong>BST-01 <strong>Tester mechanick\u00e9 pevnosti ampul\u00ed<\/strong><\/strong> od spole\u010dnosti Cell Instruments je speci\u00e1ln\u011b navr\u017een pro tento \u00fa\u010del. Poskytuje <strong>p\u0159esn\u00e9 a opakovateln\u00e9 m\u011b\u0159en\u00ed s\u00edly<\/strong>, v souladu s <strong>ISO 7500-1<\/strong> a <strong>ISO 9187<\/strong> specifikace. D\u00edky kontrolovan\u00e9 rychlosti zkou\u0161en\u00ed 10 mm\/min a rozsahu s\u00edly 200 N zaji\u0161\u0165uje BST-01 spolehliv\u00e9 v\u00fdsledky pro laborato\u0159e kontroly kvality a v\u00fdrobn\u00ed za\u0159\u00edzen\u00ed.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kl\u00ed\u010dov\u00e9 vlastnosti BST-01:<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Pln\u011b vyhovuje zku\u0161ebn\u00ed metod\u011b ISO 9187<\/li>\n\n\n\n<li>Integrovan\u00fd syst\u00e9m m\u011b\u0159en\u00ed tahov\u00e9 s\u00edly<\/li>\n\n\n\n<li>Programovateln\u00e1 rychlost a z\u00e1znam dat<\/li>\n\n\n\n<li>Ide\u00e1ln\u00ed pro <strong>m\u011b\u0159en\u00ed s\u00edly p\u0159i rozb\u00edjen\u00ed sklen\u011bn\u00fdch ampul\u00ed<\/strong><\/li>\n<\/ul>\n\n\n\n<p>Pou\u017eit\u00ed testeru BST-01 nejen zvy\u0161uje efektivitu, ale tak\u00e9 pom\u00e1h\u00e1 odhalit <strong>ned\u016fsledn\u00e9 \u017e\u00edh\u00e1n\u00ed<\/strong> nebo <strong>slab\u00e1 hydrolytick\u00e1 odolnost<\/strong>, co\u017e by mohlo ohrozit bezpe\u010dnost pacient\u016f.<\/p>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-66f05dd\" id=\"a-href-https-www-pharmacopoeiatest-com-iso-9187-1-iso-9187-a-standards-technical-testing-guidelines\" data-block-id=\"66f05dd\"><h2 class=\"stk-block-heading__text\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/cs\/iso-9187-1\/\">ISO 9187<\/a> Normy: Technick\u00e9 zku\u0161ebn\u00ed pokyny<\/h2><\/div>\n\n\n\n<p>Norma ISO 9187 popisuje metodiku a krit\u00e9ria p\u0159ijatelnosti pro hodnocen\u00ed <strong>mechanick\u00e1 pevnost ampul\u00ed<\/strong>. N\u00ed\u017ee jsou uvedeny kritick\u00e9 prvky, kter\u00e9 mus\u00edte dodr\u017eovat:<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Hydrolytick\u00e1 odolnost<\/h3>\n\n\n\n<p>Ampule mus\u00ed spl\u0148ovat <strong>ISO 4802 HC1<\/strong> t\u0159\u00edda hydrolytick\u00e9 odolnosti, kter\u00e1 zaji\u0161\u0165uje odolnost vnit\u0159n\u00edho povrchu v\u016f\u010di vodn\u00fdm roztok\u016fm.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kvalita \u017e\u00edh\u00e1n\u00ed<\/h3>\n\n\n\n<p>Ampule by nem\u011bly vykazovat optickou retardaci v\u011bt\u0161\u00ed ne\u017e <strong>50 nm\/mm tlou\u0161\u0165ky skla<\/strong>. Nespr\u00e1vn\u00e9 \u017e\u00edh\u00e1n\u00ed zvy\u0161uje vnit\u0159n\u00ed pnut\u00ed, co\u017e vede ke zlomen\u00ed p\u0159i manipulaci nebo p\u0159eprav\u011b.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Postup zkou\u0161ky s\u00edly p\u0159i p\u0159etr\u017een\u00ed<\/h3>\n\n\n\n<div class=\"wp-block-stackable-text stk-block-text stk-block stk-dda3e97\" data-block-id=\"dda3e97\"><p class=\"stk-block-text__text\">    <strong>1.P\u0159\u00edstroj:<\/strong> Pou\u017eijte tahovou zkou\u0161e\u010dku odpov\u00eddaj\u00edc\u00ed norm\u011b <strong>ISO 7500-1<\/strong>, jako je nap\u0159. <strong>BST-01 Ampulov\u00fd tester mechanick\u00e9 pevnosti<\/strong>.<br>    <strong>2.Testovac\u00ed rychlost:<\/strong> 10 mm\/min nebo ekvivalentn\u00ed s\u00edla 20 N\/s.<br>    <strong>3.Force Range:<\/strong> Nejm\u00e9n\u011b 200 N.<br>    <strong>4.P\u0159\u00edprava vzorku:<\/strong><br>             Stav na <strong>20 \u00b1 5 \u00b0C<\/strong>.<br>             V\u00fdb\u011br vzork\u016f podle <strong>ISO 2859-1<\/strong>, \u00farove\u0148 kontroly S-4.<br>    <strong>5.Nastaven\u00ed:<\/strong><br>            Ampulku um\u00edst\u011bte mezi dv\u011b ty\u010de.<br>            P\u016fsobte silou pod \u00fahlem 90\u00b0 k jeho ose.<br>            Rozbit\u00ed by m\u011blo b\u00fdt \u010dist\u00e9 a zaznamen\u00e1no silou.<\/p><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Poloha a stabilita bodu zlomu (ISO 9187-2)<\/h3>\n\n\n\n<figure class=\"wp-block-embed alignright is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<div class=\"ast-oembed-container\" style=\"height: 100%;\"><iframe title=\"Zkou\u0161e\u010dka na poru\u0161en\u00ed ampul\u00ed ISO 9187-1 BST-01\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/fL78KBZwj3g?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/div>\n<\/div><\/figure>\n\n\n\n<div class=\"wp-block-stackable-text stk-block-text stk-block stk-74b8b2e\" data-block-id=\"74b8b2e\"><p class=\"stk-block-text__text\">                                               Barevn\u011b ozna\u010den\u00fd bod zlomu mus\u00ed b\u00fdt <strong>vycentrov\u00e1no \u00b11 mm<\/strong>.<br>                                               Mus\u00ed vydr\u017eet:<br>                                                   <strong>30 minut p\u0159i 120 \u00b0C<\/strong>, pak pono\u0159en\u00ed do <strong>30 \u00b0C vody<\/strong><br>                                                   <strong>Steriliza\u010dn\u00ed cykly a \u010distic\u00ed rozpou\u0161t\u011bdla<\/strong><br>                                               Nedodr\u017een\u00ed t\u011bchto pokyn\u016f m\u016f\u017ee m\u00edt za n\u00e1sledek nadm\u011brnou s\u00edlu p\u0159i rozb\u00edjen\u00ed, co\u017e m\u016f\u017ee v\u00e9st k tomu, \u017ee ampule nebude bezpe\u010dn\u00e1 nebo nebude vyhovovat po\u017eadavk\u016fm.<\/p><\/div>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-d535f6f\" id=\"why-mechanical-strength-testing-matters\" data-block-id=\"d535f6f\"><h2 class=\"stk-block-heading__text\">                Pro\u010d je d\u016fle\u017eit\u00e9 zkou\u0161en\u00ed mechanick\u00e9 pevnosti<\/h2><\/div>\n\n\n\n<p>P\u0159edstaven\u00ed <strong>test mechanick\u00e9 pevnosti ampul\u00ed<\/strong> nejde jen o p\u0159ijet\u00ed na\u0159\u00edzen\u00ed. Zaji\u0161\u0165uje:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Bezpe\u010dnost pacient\u016f:<\/strong> zabr\u00e1n\u011bn\u00ed vzniku sklen\u011bn\u00fdch \u010d\u00e1stic nebo n\u00e1siln\u00e9mu rozbit\u00ed.<\/li>\n\n\n\n<li><strong>Konzistence v\u00fdroby:<\/strong> v\u010dasn\u00e9 odhalen\u00ed nedostatk\u016f<\/li>\n\n\n\n<li><strong>Dodr\u017eov\u00e1n\u00ed pr\u00e1vn\u00edch p\u0159edpis\u016f:<\/strong> p\u0159edch\u00e1zen\u00ed odm\u00edtnut\u00ed a sta\u017een\u00ed z trhu<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">P\u0159\u00edklad z re\u00e1ln\u00e9ho sv\u011bta:<\/h3>\n\n\n\n<p>P\u0159edn\u00ed farmaceutick\u00fd z\u00e1vod pou\u017e\u00edvaj\u00edc\u00ed BST-01 dos\u00e1hl <strong>Redukce 30%<\/strong> v reklamac\u00edch souvisej\u00edc\u00edch s rozbit\u00edm ampul\u00ed po standardizaci test\u016f v souladu s normou ISO 9187.<\/p>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-25932c4\" id=\"choosing-the-right-ampoule-mechanical-strength-tester\" data-block-id=\"25932c4\"><h2 class=\"stk-block-heading__text\">V\u00fdb\u011br spr\u00e1vn\u00e9 ampulov\u00e9 zkou\u0161e\u010dky mechanick\u00e9 pevnosti.<\/h2><\/div>\n\n\n\n<p>Spole\u010dnost Cell Instruments se specializuje na vysoce p\u0159esn\u00e9 mechanick\u00e9 zku\u0161ebn\u00ed syst\u00e9my. Na <strong>BST-01 Ampulov\u00fd tester mechanick\u00e9 pevnosti<\/strong> je optimalizov\u00e1n pro <strong>test mechanick\u00e9 pevnosti ampul\u00ed<\/strong> a podporuje automatizaci, dohledatelnost dat a snadn\u00e9 pou\u017e\u00edv\u00e1n\u00ed obsluhou.<\/p>\n\n\n\n<p>S des\u00edtkami let zku\u0161enost\u00ed v oblasti <strong>testov\u00e1n\u00ed obal\u016f zdravotnick\u00fdch prost\u0159edk\u016f a l\u00e9\u010div<\/strong>, Cell Instruments nab\u00edz\u00ed \u0159e\u0161en\u00ed na m\u00edru pro:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Kontrola kvality injek\u010dn\u00edch ampul\u00ed<\/li>\n\n\n\n<li>Charakteristika materi\u00e1lu<\/li>\n\n\n\n<li>Vlastn\u00ed automatizovan\u00e1 testovac\u00ed nastaven\u00ed<\/li>\n<\/ul>\n\n\n\n<p>Pokud v\u00e1\u0161 pracovn\u00ed postup kontroly kvality zahrnuje sklen\u011bn\u00e9 ampule, BST-01 poskytuje bezkonkuren\u010dn\u00ed <strong>p\u0159esnost, opakovatelnost a shoda<\/strong>.<\/p>\n\n\n\n<div class=\"wp-block-stackable-heading stk-block-heading stk-block-heading--v2 stk-block stk-cea0f97\" id=\"conclusion\" data-block-id=\"cea0f97\"><h2 class=\"stk-block-heading__text\">Z\u00e1v\u011br<\/h2><\/div>\n\n\n\n<div class=\"wp-block-stackable-text stk-block-text stk-block stk-08e63b8\" data-block-id=\"08e63b8\"><style>.stk-08e63b8{margin-bottom:0px !important}.stk-08e63b8 .stk-block-text__text{text-shadow:none !important}<\/style><p class=\"stk-block-text__text\">Zaji\u0161t\u011bn\u00ed mechanick\u00e9 pevnosti ampul\u00ed m\u00e1 z\u00e1sadn\u00ed v\u00fdznam pro farmaceutickou integritu a bezpe\u010dnost pacient\u016f. Dodr\u017eov\u00e1n\u00edm <a href=\"https:\/\/www.iso.org\/standard\/55920.html\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>ISO 9187<\/strong> <\/a>a s vyu\u017eit\u00edm modern\u00edho vybaven\u00ed, jako je nap\u0159. <strong>BST-01 Ampulov\u00fd tester mechanick\u00e9 pevnosti<\/strong>, mohou v\u00fdrobci s jistotou ov\u011b\u0159it <strong>m\u011b\u0159en\u00ed s\u00edly p\u0159i rozb\u00edjen\u00ed sklen\u011bn\u00fdch ampul\u00ed<\/strong>. P\u0159esn\u00e9 testov\u00e1n\u00ed nejen zaru\u010duje kvalitu v\u00fdrobk\u016f, ale tak\u00e9 zvy\u0161uje shodu s p\u0159edpisy a d\u016fv\u011bru z\u00e1kazn\u00edk\u016f.<br>Pro laborato\u0159e a v\u00fdrobce, kte\u0159\u00ed hledaj\u00ed spolehliv\u00e1 testovac\u00ed \u0159e\u0161en\u00ed v souladu s ISO, <strong>Cell Instruments' BST-01<\/strong> je osv\u011bd\u010denou volbou pro podporu va\u0161eho programu testov\u00e1n\u00ed ampul\u00ed.<\/p><\/div>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>P\u0159esn\u00e9 vyhodnocen\u00ed testeru mechanick\u00e9 pevnosti ampul\u00ed m\u00e1 z\u00e1sadn\u00ed v\u00fdznam p\u0159i kontrole kvality l\u00e9\u010div. Sklen\u011bn\u00e9 ampule pou\u017e\u00edvan\u00e9 pro injek\u010dn\u00ed roztoky mus\u00ed b\u00fdt dostate\u010dn\u011b pevn\u00e9, aby si zachovaly sterilitu b\u011bhem p\u0159epravy a skladov\u00e1n\u00ed, a z\u00e1rove\u0148 dostate\u010dn\u011b snadno otev\u0159en\u00e9 bez pou\u017eit\u00ed nadm\u011brn\u00e9 s\u00edly. Norma ISO 9187 stanov\u00ed standardizovan\u00e9 zku\u0161ebn\u00ed postupy pro hodnocen\u00ed t\u011bchto vlastnost\u00ed, zejm\u00e9na m\u011b\u0159en\u00ed s\u00edly p\u0159i l\u00e1m\u00e1n\u00ed sklen\u011bn\u00fdch ampul\u00ed, kter\u00e9 [...]<\/p>","protected":false},"author":1,"featured_media":2280,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2267","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"thumbnail":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-150x150.webp",150,150,true],"medium":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c-300x300.webp",300,300,true],"medium_large":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"large":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"1536x1536":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"2048x2048":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",600,600,false],"trp-custom-language-flag":["https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/07\/BST-01-Ampoule-Break-Strength-Tester-01_\u526f\u672c_\u526f\u672c.webp",12,12,false]},"uagb_author_info":{"display_name":"Admin","author_link":"https:\/\/www.pharmacopoeiatest.com\/cs\/author\/admin\/"},"uagb_comment_info":0,"uagb_excerpt":"Accurate evaluation of ampoule mechanical strength tester is critical in pharmaceutical quality control. Glass ampoules used for injectable solutions must be strong enough to maintain sterility during transportation and storage, yet easy enough to break open without excessive force. ISO 9187 provides standardized test procedures to assess these qualities, especially breaking force measurement for glass&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/posts\/2267","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/comments?post=2267"}],"version-history":[{"count":5,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/posts\/2267\/revisions"}],"predecessor-version":[{"id":2300,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/posts\/2267\/revisions\/2300"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/media\/2280"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/media?parent=2267"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/categories?post=2267"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/tags?post=2267"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}