{"id":2036,"date":"2025-04-14T09:07:36","date_gmt":"2025-04-14T09:07:36","guid":{"rendered":"https:\/\/www.pharmacopoeiatest.com\/?p=2036"},"modified":"2025-04-22T03:29:56","modified_gmt":"2025-04-22T03:29:56","slug":"syringe-leakage-testing-iso-11040-4","status":"publish","type":"post","link":"https:\/\/www.pharmacopoeiatest.com\/cs\/syringe-leakage-testing-iso-11040-4\/","title":{"rendered":"Zkou\u0161ka t\u011bsnosti st\u0159\u00edka\u010dky - ISO 11040-4, p\u0159\u00edloha G2"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"2036\" class=\"elementor elementor-2036\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-b47b928 e-flex e-con-boxed e-con e-parent\" data-id=\"b47b928\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e8261b4 elementor-widget elementor-widget-heading\" data-id=\"e8261b4\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Testov\u00e1n\u00ed t\u011bsnosti st\u0159\u00edka\u010dky<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a6fa5bf elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"a6fa5bf\" data-element_type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03e5049 elementor-widget elementor-widget-heading\" data-id=\"03e5049\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 P\u0159\u00edloha G2<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b2170a2 e-flex e-con-boxed e-con e-parent\" data-id=\"b2170a2\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ec36001 elementor-widget elementor-widget-text-editor\" data-id=\"ec36001\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"375\" data-end=\"1050\">V oblasti v\u00fdroby l\u00e9\u010div a zdravotnick\u00fdch prost\u0159edk\u016f, <em data-start=\"459\" data-end=\"484\">testov\u00e1n\u00ed t\u011bsnosti injek\u010dn\u00edch st\u0159\u00edka\u010dek<\/em> je d\u016fle\u017eit\u00fdm procesem zaji\u0161t\u011bn\u00ed kvality. Zaji\u0161\u0165uje, \u017ee <strong data-start=\"542\" data-end=\"564\">p\u0159edpln\u011bn\u00e9 injek\u010dn\u00ed st\u0159\u00edka\u010dky<\/strong> zachov\u00e1vaj\u00ed sterilitu a b\u011bhem p\u0159epravy, skladov\u00e1n\u00ed nebo pou\u017e\u00edv\u00e1n\u00ed net\u011bsn\u00ed. Aby v\u00fdrobci splnili p\u0159\u00edsn\u00e9 po\u017eadavky p\u0159edpis\u016f, mus\u00ed dodr\u017eovat mezin\u00e1rodn\u00ed normy, jako jsou nap\u0159. <strong data-start=\"736\" data-end=\"751\">ISO 11040-4<\/strong>, zejm\u00e9na <strong data-start=\"764\" data-end=\"776\">P\u0159\u00edloha G2<\/strong>, kter\u00e1 popisuje <strong data-start=\"797\" data-end=\"830\">metoda zkou\u0161en\u00ed t\u011bsnosti kapalin<\/strong> pro syst\u00e9my uzav\u00edr\u00e1n\u00ed injek\u010dn\u00edch st\u0159\u00edka\u010dek.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ebf1ff6 elementor-widget elementor-widget-heading\" data-id=\"ebf1ff6\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Co je testov\u00e1n\u00ed t\u011bsnosti st\u0159\u00edka\u010dky?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1f9a4f4 elementor-widget elementor-widget-text-editor\" data-id=\"1f9a4f4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"1115\" data-end=\"1487\">Testov\u00e1n\u00ed t\u011bsnosti st\u0159\u00edka\u010dky hodnot\u00ed, zda je syst\u00e9m uz\u00e1v\u011bru st\u0159\u00edka\u010dky - bu\u010f <strong data-start=\"1232\" data-end=\"1249\">\u0161t\u00edt jehly<\/strong> nebo <strong data-start=\"1253\" data-end=\"1264\">\u010depice se \u0161pi\u010dkou<\/strong>-vydr\u017e\u00ed vnit\u0159n\u00ed tlak, ani\u017e by do\u0161lo k \u00faniku tekutiny. Podle <strong data-start=\"1344\" data-end=\"1368\">ISO 11040-4 P\u0159\u00edloha G2<\/strong>, standardn\u00ed zku\u0161ebn\u00ed tlak je <strong data-start=\"1400\" data-end=\"1411\">110 kPa<\/strong>, simuluj\u00edc\u00ed re\u00e1ln\u00e9 podm\u00ednky p\u0159i pln\u011bn\u00ed nebo p\u0159eprav\u011b injek\u010dn\u00edch st\u0159\u00edka\u010dek.<\/p><h3 data-start=\"1489\" data-end=\"1718\">Pro\u010d na tom z\u00e1le\u017e\u00ed<\/h3><p class=\"\" data-start=\"1489\" data-end=\"1718\">Net\u011bsnost nejen\u017ee ohro\u017euje sterilitu v\u00fdrobku, ale m\u016f\u017ee tak\u00e9 zp\u016fsobit nep\u0159esnost d\u00e1vkov\u00e1n\u00ed a bezpe\u010dnostn\u00ed rizika. Po <strong data-start=\"1626\" data-end=\"1657\">standardizovan\u00fd zku\u0161ebn\u00ed postup<\/strong> zaji\u0161\u0165uje konzistenci, spolehlivost a soulad s p\u0159edpisy.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d11a485 elementor-widget elementor-widget-heading\" data-id=\"d11a485\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span style=\"font-size: 2.82353rem;\">ISO 11040-4 P\u0159\u00edloha G2 <\/span>Po\u017eadavky na testov\u00e1n\u00ed<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-036bd3c e-con-full e-flex e-con e-child\" data-id=\"036bd3c\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-7d2acf2 e-con-full e-flex e-con e-child\" data-id=\"7d2acf2\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-f8616b8 e-con-full e-flex e-con e-child\" data-id=\"f8616b8\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3773a30 elementor-widget elementor-widget-heading\" data-id=\"3773a30\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Vzorek pro testov\u00e1n\u00ed t\u011bsnosti st\u0159\u00edka\u010dky<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f461568 elementor-widget elementor-widget-text-editor\" data-id=\"f461568\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p>Pou\u017e\u00edvejte pouze \u010dinidla analytick\u00e9 kvality a steriln\u00ed, k pln\u011bn\u00ed p\u0159ipraven\u00e9 st\u0159\u00edka\u010dky. Vzorky mus\u00ed z\u016fstat nedot\u010den\u00e9 po dobu <strong data-start=\"1927\" data-end=\"1948\">nejm\u00e9n\u011b 12 hodin<\/strong> po nastaven\u00ed uz\u00e1v\u011bru p\u0159ed zah\u00e1jen\u00edm testov\u00e1n\u00ed. Tato doba zdr\u017een\u00ed zaji\u0161\u0165uje stabilizaci uz\u00e1v\u011bru.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-551a42f elementor-widget elementor-widget-heading\" data-id=\"551a42f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Tester t\u011bsnosti st\u0159\u00edka\u010dky<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9fd1b0f elementor-widget elementor-widget-text-editor\" data-id=\"9fd1b0f\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2046\" data-end=\"2117\">P\u0159\u00edloha G2 specifikuje dv\u011b hlavn\u00ed zku\u0161ebn\u00ed metody:<\/p><ul><li data-start=\"2120\" data-end=\"2211\"><strong data-start=\"2120\" data-end=\"2149\">Mechanick\u00e9 p\u0159etlakov\u00e1n\u00ed<\/strong> pomoc\u00ed <strong data-start=\"2158\" data-end=\"2211\">univerz\u00e1ln\u00ed stroj pro zkou\u0161en\u00ed v tahu a tlaku<\/strong><\/li><li data-start=\"2120\" data-end=\"2211\"><strong style=\"font-size: 16px;\" data-start=\"2214\" data-end=\"2253\">Tlakov\u00e1n\u00ed na b\u00e1zi stla\u010den\u00e9ho vzduchu<\/strong><span style=\"font-size: 16px;\">, up\u0159ednost\u0148ovan\u00e9 tam, kde t\u0159en\u00ed st\u011bn ovliv\u0148uje p\u0159esnost<\/span><\/li><\/ul><p class=\"\" data-start=\"2303\" data-end=\"2494\"><strong data-start=\"2303\" data-end=\"2354\">MST-01 Medical Syringe Tester od spole\u010dnosti Cell Instruments<\/strong> nab\u00edz\u00ed komplexn\u00ed \u0159e\u0161en\u00ed. Podporuje zkou\u0161ky zalo\u017een\u00e9 na s\u00edle i tlaku, co\u017e je ide\u00e1ln\u00ed pro zaji\u0161t\u011bn\u00ed shody s normami ISO.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8d3d2fd elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"8d3d2fd\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"488\" height=\"1024\" src=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp\" class=\"attachment-large size-large wp-image-2048\" alt=\"ISO 11040-4 testov\u00e1n\u00ed t\u011bsnosti injek\u010dn\u00edch st\u0159\u00edka\u010dek\" srcset=\"https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-488x1024.webp 488w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-143x300.webp 143w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-768x1613.webp 768w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-731x1536.webp 731w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-975x2048.webp 975w, https:\/\/www.pharmacopoeiatest.com\/wp-content\/uploads\/2025\/04\/ISO-11040-4-Syringe-Leakage-Testing-scaled.webp 1219w\" sizes=\"(max-width: 488px) 100vw, 488px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d84a26e elementor-widget elementor-widget-heading\" data-id=\"d84a26e\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Postup testov\u00e1n\u00ed t\u011bsnosti st\u0159\u00edka\u010dky<\/h3>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-1a41478 e-grid e-con-full e-con e-child\" data-id=\"1a41478\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-51c8a4e elementor-widget elementor-widget-text-editor\" data-id=\"51c8a4e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ol data-start=\"2526\" data-end=\"2787\"><li class=\"\" data-start=\"2526\" data-end=\"2603\"><p class=\"\" data-start=\"2529\" data-end=\"2603\">Vlo\u017ete st\u0159\u00edka\u010dku do <strong data-start=\"2555\" data-end=\"2573\">dr\u017e\u00e1k injek\u010dn\u00ed st\u0159\u00edka\u010dky<\/strong> se zav\u00edrac\u00edm syst\u00e9mem.<\/p><\/li><li class=\"\" data-start=\"2604\" data-end=\"2665\"><p class=\"\" data-start=\"2607\" data-end=\"2665\">Napl\u0148te destilovanou vodou do 1\/3 a\u017e 2\/3 jmenovit\u00e9ho objemu.<\/p><\/li><li class=\"\" data-start=\"2666\" data-end=\"2706\"><p class=\"\" data-start=\"2669\" data-end=\"2706\">Po dobu 5 sekund vyv\u00edjejte tlak 110 kPa.<\/p><\/li><li class=\"\" data-start=\"2707\" data-end=\"2787\"><p class=\"\" data-start=\"2710\" data-end=\"2787\">Uvoln\u011bte tlak a <strong data-start=\"2731\" data-end=\"2764\">kontrola vn\u011bj\u0161\u00edch kapek<\/strong> nebo odpojen\u00ed krytky hrotu.<\/p><\/li><\/ol><p class=\"\" data-start=\"2789\" data-end=\"2867\">Tato metoda replikuje sc\u00e9n\u00e1\u0159e p\u0159etlaku a potvrzuje integritu t\u011bsn\u011bn\u00ed.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5676ace elementor-widget elementor-widget-video\" data-id=\"5676ace\" data-element_type=\"widget\" data-settings=\"{&quot;youtube_url&quot;:&quot;https:\\\/\\\/www.youtube.com\\\/watch?v=XHOmBV4js_E&quot;,&quot;video_type&quot;:&quot;youtube&quot;,&quot;controls&quot;:&quot;yes&quot;}\" data-widget_type=\"video.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"elementor-wrapper elementor-open-inline\">\n\t\t\t<div class=\"elementor-video\"><\/div>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-2614162 e-flex e-con-boxed e-con e-parent\" data-id=\"2614162\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-72ac59a elementor-widget elementor-widget-heading\" data-id=\"72ac59a\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ISO 11040-4 Testov\u00e1n\u00ed Interpretace v\u00fdsledk\u016f<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-70afec8 elementor-widget elementor-widget-text-editor\" data-id=\"70afec8\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"2904\" data-end=\"2921\">Proj\u00edt testem:<\/p><ul><li data-start=\"2924\" data-end=\"3001\"><strong data-start=\"2924\" data-end=\"2946\">\u017d\u00e1dn\u00e9 kapky kapaliny<\/strong> by m\u011bl b\u00fdt viditeln\u00fd kolem krytu hrotu nebo \u0161t\u00edtu jehly.<\/li><li data-start=\"2924\" data-end=\"3001\"><span style=\"font-size: 16px;\">Uz\u00e1v\u011brka mus\u00ed <\/span><strong style=\"font-size: 16px;\" data-start=\"3021\" data-end=\"3040\">z\u016fstat na m\u00edst\u011b<\/strong><span style=\"font-size: 16px;\">.<\/span><\/li><li data-start=\"3004\" data-end=\"3041\"><span style=\"font-size: 16px;\">Vizu\u00e1ln\u00ed kontrola potvrd\u00ed, zda st\u0159\u00edka\u010dka pro\u0161la nebo nepro\u0161la.<\/span><\/li><\/ul><p class=\"\" data-start=\"3103\" data-end=\"3134\">Zpr\u00e1va o zkou\u0161ce by m\u011bla obsahovat:<\/p><ul><li data-start=\"3137\" data-end=\"3162\">Pou\u017eit\u00fd tlak nebo s\u00edla<\/li><li data-start=\"3137\" data-end=\"3162\">Po\u010det testovan\u00fdch vzork\u016f<\/li><li data-start=\"3137\" data-end=\"3162\">Po\u010det \u00fasp\u011b\u0161n\u00fdch nebo ne\u00fasp\u011b\u0161n\u00fdch<\/li><li data-start=\"3137\" data-end=\"3162\">Ve\u0161ker\u00e9 odchylky zji\u0161t\u011bn\u00e9 b\u011bhem zkou\u0161ky<\/li><\/ul><p class=\"\" data-start=\"3259\" data-end=\"3336\">Spr\u00e1vn\u00e1 dokumentace je nezbytn\u00e1 pro regula\u010dn\u00ed audity a sledov\u00e1n\u00ed kvality.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-87c6b33 elementor-widget elementor-widget-heading\" data-id=\"87c6b33\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Tester t\u011bsnosti p\u0159edpln\u011bn\u00fdch st\u0159\u00edka\u010dek<small>--Dal\u0161\u00ed aplikace<\/small><\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cd20d14 elementor-widget elementor-widget-text-editor\" data-id=\"cd20d14\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"3408\" data-end=\"3534\"><strong data-start=\"3408\" data-end=\"3435\">Testov\u00e1n\u00ed t\u011bsnosti st\u0159\u00edka\u010dky<\/strong> je pouze jedn\u00edm z aspekt\u016f <strong data-start=\"3458\" data-end=\"3487\">testov\u00e1n\u00ed p\u0159edpln\u011bn\u00fdch injek\u010dn\u00edch st\u0159\u00edka\u010dek<\/strong> pod <a href=\"https:\/\/www.iso.org\/standard\/82222.html\" target=\"_blank\" rel=\"noopener\">ISO 11040-4<\/a>. V\u00fdrobci tak\u00e9 zkoumaj\u00ed:<\/p><ul><li data-start=\"3537\" data-end=\"3567\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/cs\/syringe-glide-force-testing-iso-11040-4\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"3537\" data-end=\"3567\">Kluzn\u00fd odpor p\u00edstu<\/strong><\/a><\/li><li data-start=\"3537\" data-end=\"3567\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/cs\/syringes-needle-penetration-test-iso-11040-4\/\" target=\"_blank\" rel=\"noopener\"><strong style=\"font-size: 16px;\" data-start=\"3570\" data-end=\"3598\">S\u00edla pr\u016fniku jehly<\/strong><\/a><\/li><li data-start=\"3537\" data-end=\"3567\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/cs\/needle-bonding-strength-test-iso-11040-4\/\" target=\"_blank\" rel=\"noopener\"><strong style=\"font-size: 16px;\" data-start=\"3601\" data-end=\"3641\">Pevnost spoje mezi jehlou a n\u00e1bojem<\/strong><\/a><\/li><li data-start=\"3537\" data-end=\"3567\"><a href=\"https:\/\/www.pharmacopoeiatest.com\/cs\/syringe-glide-force-testing-iso-11040-4\/\" target=\"_blank\" rel=\"noopener\"><strong style=\"font-size: 16px;\" data-start=\"3644\" data-end=\"3676\">Udr\u017eov\u00e1n\u00ed p\u00edstu (vytahov\u00e1n\u00ed)<\/strong><\/a><\/li><\/ul><p class=\"\" data-start=\"3678\" data-end=\"3926\"><strong data-start=\"3678\" data-end=\"3688\">MST-01<\/strong> integruje tyto funkce do jedin\u00e9 kompaktn\u00ed testovac\u00ed jednotky. Umo\u017e\u0148uje \u00fapln\u00e9 mechanick\u00e9 ov\u011b\u0159en\u00ed <strong data-start=\"3796\" data-end=\"3833\">pr\u00e1zdn\u00e9 steriln\u00ed injek\u010dn\u00ed st\u0159\u00edka\u010dky na jedno pou\u017eit\u00ed<\/strong>, spl\u0148uj\u00edc\u00ed nejen normu ISO 11040-4, ale tak\u00e9 <a href=\"https:\/\/www.pharmacopoeiatest.com\/cs\/iso-7886-1\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"3880\" data-end=\"3894\">ISO 7886-1<\/strong><\/a>, <strong data-start=\"3896\" data-end=\"3908\">ISO 8537<\/strong>a <strong data-start=\"3914\" data-end=\"3925\">USP 382<\/strong>.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1288b5d elementor-widget elementor-widget-heading\" data-id=\"1288b5d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Pro\u010d zvolit MST-01 pro testov\u00e1n\u00ed t\u011bsnosti injek\u010dn\u00edch st\u0159\u00edka\u010dek?<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-601b24a elementor-widget elementor-widget-text-editor\" data-id=\"601b24a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<p class=\"\" data-start=\"4001\" data-end=\"4057\">Na str\u00e1nk\u00e1ch <strong data-start=\"4005\" data-end=\"4038\">MST-01 Tester l\u00e9ka\u0159sk\u00fdch st\u0159\u00edka\u010dek<\/strong> vynik\u00e1:<\/p><ul><li data-start=\"4060\" data-end=\"4110\"><strong data-start=\"4060\" data-end=\"4085\">Mo\u017enost v\u00edcen\u00e1sobn\u00e9ho testov\u00e1n\u00ed<\/strong> zabudovan\u00e9 v jedn\u00e9 platform\u011b<\/li><li data-start=\"4060\" data-end=\"4110\"><strong style=\"font-size: 16px;\" data-start=\"4113\" data-end=\"4138\">Syst\u00e9m \u0159\u00edzen\u00fd PLC<\/strong><span style=\"font-size: 16px;\"> a 7palcovou dotykovou obrazovkou<\/span><\/li><li data-start=\"4060\" data-end=\"4110\"><strong style=\"font-size: 16px;\" data-start=\"4164\" data-end=\"4209\">P\u0159esn\u00e9 ovl\u00e1d\u00e1n\u00ed s\u00edly a posunu<\/strong><\/li><li data-start=\"4060\" data-end=\"4110\"><strong style=\"font-size: 16px;\" data-start=\"4212\" data-end=\"4236\">Monitorov\u00e1n\u00ed v re\u00e1ln\u00e9m \u010dase<\/strong><span style=\"font-size: 16px;\"> a vestav\u011bnou mikrotisk\u00e1rnou<\/span><\/li><\/ul><p class=\"\" data-start=\"4264\" data-end=\"4549\">Tato v\u0161estrannost zaji\u0161\u0165uje p\u0159esn\u00e9, efektivn\u00ed a reprodukovateln\u00e9 testov\u00e1n\u00ed t\u011bsnosti st\u0159\u00edka\u010dek a z\u00e1rove\u0148 spl\u0148uje celosv\u011btov\u00e9 normy. D\u00edky p\u0159izp\u016fsobiteln\u00fdm p\u0159\u00edpravk\u016fm a programovateln\u00fdm testovac\u00edm nastaven\u00edm poskytuje MST-01 <strong data-start=\"4458\" data-end=\"4476\">n\u00e1kladov\u011b efektivn\u00ed<\/strong> a <strong data-start=\"4481\" data-end=\"4498\">u\u017eivatelsky p\u0159\u00edv\u011btiv\u00e9<\/strong> \u0159e\u0161en\u00ed pro t\u00fdmy kontroly kvality ve farmaceutick\u00e9m pr\u016fmyslu.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Syringe Leakage Testing ISO 11040-4 Annex G2 In the field of pharmaceutical and medical device manufacturing, syringe leakage testing is a critical quality assurance process. It ensures that prefilled syringes maintain sterility and do not leak during transport, storage, or use. To meet stringent regulatory expectations, manufacturers must follow international standards such as ISO 11040-4, [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[26],"tags":[],"class_list":["post-2036","post","type-post","status-publish","format-standard","hentry","category-blog"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"pharmacopoeiatest","author_link":"https:\/\/www.pharmacopoeiatest.com\/cs\/author\/pharmacopoeiatest\/"},"uagb_comment_info":0,"uagb_excerpt":"Syringe Leakage Testing ISO 11040-4 Annex G2 In the field of pharmaceutical and medical device manufacturing, syringe leakage testing is a critical quality assurance process. It ensures that prefilled syringes maintain sterility and do not leak during transport, storage, or use. To meet stringent regulatory expectations, manufacturers must follow international standards such as ISO 11040-4,&hellip;","_links":{"self":[{"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/posts\/2036","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/comments?post=2036"}],"version-history":[{"count":6,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/posts\/2036\/revisions"}],"predecessor-version":[{"id":2055,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/posts\/2036\/revisions\/2055"}],"wp:attachment":[{"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/media?parent=2036"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/categories?post=2036"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pharmacopoeiatest.com\/cs\/wp-json\/wp\/v2\/tags?post=2036"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}